Isothermal nucleic acid amplification tests (NAAT) in a Lab-on-a-Chip (LoC) format promise to bring high-accuracy, non-instrumented rapid tests to the point of care. Reliable rapid tests for infectious diseases allow for early diagnosis and treatment, which in turn enables better containment of potential outbreaks and fewer complications. A critical component to LoC NAATs is the heating element, as all NAAT protocols require incubation at elevated temperatures. We propose a cheap, integrated, self-regulating resistive heating solution that uses 2xAAA alkaline batteries as the power source, can maintain temperatures in the 60–63°C range for at least 25 minutes, and reaches the target range from room temperature in 5 minutes. 4 heating element samples with different electrical characteristics were evaluated in a thermal mock-up for a LoC NAAT device. An optimal heating element candidate was chosen based on temperature profiling. The optimal candidate was further evaluated by thermal modelling via finite element analysis of heat transfer and demonstrated suitable for isothermal nucleic acid amplification.
The binding affinity of a series of cell-penetrating peptides (CPP) was modeled through docking and making use of the number of intermolecular hydrogen bonds, lipophilic contacts, and the number of sp3 molecular orbital hybridization carbons. The new ranking of the peptides is consistent with the experimentally determined efficiency in the downregulation of luciferase activity, which includes the peptides’ ability to bind and deliver the siRNA into the cell. The predicted structures of the complexes of peptides to siRNA were stable throughout 10 ns long, explicit water molecular dynamics simulations. The stability and binding affinity of peptide-siRNA complexes was related to the sidechains and modifications of the CPPs, with the stearyl and quinoline groups improving affinity and stability. The reranking of the peptides docked to siRNA, together with explicit water molecular dynamics simulations, appears to be well suited to describe and predict the interaction of CPPs with siRNA.
Non-instrumented nucleic acid amplification tests (NINAAT) are a novel paradigm in portable molecular diagnostics. They offer the high detection accuracy characteristic of nucleic acid amplification tests (NAAT) in a self-contained device, without the need for any external instrumentation. These Point-of-Care tests typically employ a Lab-on-a-Chip for liquid handling functionality, and perform isothermal nucleic acid amplification protocols that require low power but high accuracy temperature control in a single well-defined temperature range. We propose temperature control solutions based on commercially available heating elements capable of meeting these challenges, as well as demonstrate the process by which such elements can be fitted to a NINAAT system. Self-regulated and thermostat-controlled resistive heating elements were evaluated through experimental characterization as well as thermal analysis using the finite element method (FEM). We demonstrate that the proposed solutions can support various NAAT protocols, as well as demonstrate an optimal solution for the loop-mediated isothermal amplification (LAMP) protocol. Furthermore, we present an Arduino-compatible open-source thermostat developed for NINAAT applications.
Novel second-generation rapid diagnostics based on nucleic acid amplification tests (NAAT) offer performance metrics on par with clinical laboratories in detecting infectious diseases at the point of care. The diagnostic assay is typically performed within a Lab-on-a-Chip (LoC) component with integrated temperature regulation. However, constraints on device dimensions, cost and power supply inherent with the device format apply to temperature regulation as well. Thermal analysis on simplified thermal models for the device can help overcome these barriers by speeding up thermal optimization. In this work, we perform experimental thermal analysis on the simplified thermal model for our instrument-free, single-use LoC NAAT platform. The system is evaluated further by finite element modelling. Steady-state as well as transient thermal analysis are performed to evaluate the performance of a self-regulating polymer resin heating element in the proposed device geometry. Reaction volumes in the target temperature range of the amplification reaction are estimated in the simulated model to assess compliance with assay requirements. Using the proposed methodology, we demonstrated our NAAT device concept capable of performing loop-mediated isothermal amplification in the 20–25 °C ambient temperature range with 32 min total assay time.
Certain novel molecular diagnostics Point-of-Care applications require precise temperature control (±1-5 °C) over an extended time (15-60 minutes) for proper function. Microheating components in portable tests must meet strict criteria with respect to size and power consumption, both of which may be met with thermoelectric heating. Our proposed finite element model is intended to provide tools for the evaluation of thermoelectric heating for molecular diagnostics as well as aid in iterative device design and in silico validation of device designs. The proposed model was developed for and validated with a commercially available thermoelectric cooler. A 3D printed test structure was created to house a glass microfluidic chip (<;0.1 ml channel volume) and the heating element, imitating a tiny portable Point-of-Care test. Experimental setups were evaluated in the operating input voltage range of the heating element. Physical parameters of the setup were fed into the finite element model and a comparison made between simulated and physical temperature recordings.