Rui Guo

Rui Guo

Auto-generated profile, based on publicly available information

Rui Guo

Beijing National Research Center for Information Science and Technology (BNRist), School of Integrated Circuits, Tsinghua University, Beijing 100084, China

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2021 in IEEE Sensors Journal
Verified
Journal Article
Open access
RGRui Guo
Rui Guo
XCXiang Cheng
Xiang Cheng
ZHZong-Chen Hou
Zong-Chen Hou
JMJing-Zhong Ma
Jing-Zhong Ma
WZWen-Qiang Zheng
Wen-Qiang Zheng
TRTian-Ling Ren
Tian-Ling Ren
In clinical, the center of pressure (CoP) is commonly used for accessing the stability of a person’s postural control, which is highly associated with various neurological diseases and movement disorders such as Alzheimer’s disease, Parkinson’s disease, chronic ankle instability. Such a disease usually has a long development or rehabilitation process which requires long-term CoP monitoring. The current CoP evaluation process does not meet the requirement, as it is often complicated and expensive through either the lab-based equipment or the clinical evaluation procedure. Different wearable sensor-based systems with less cost and restrictions have emerged, but their way of CoP calculation requires deliberate calibration of the positions of their sensors, which are not feasible in daily CoP monitoring. In this study, we developed a long-term CoP monitoring system in a smart-shoe form. First, a thin and flexible smart insole with optimal sensor locations was designed to be compact and energy sufficient for a whole-day usage. Then, a user-friendly app on the smartphone with a cloud-based data managing system was developed for applications in both clinical and home environments. Additionally, a simplified CoP estimation model was created without the need for calibration. Lastly, a machine learning-based human activity recognition method was incorporated to make the CoP detection process more automatic. Through a thorough validation test with the clinical level lab equipment, our system can generate the CoP measurements with high accuracy.

24 February 2010 in Optics Express
Verified
Journal Article
Open access
PDF file
RGRui Guo
Rui Guo
EKEdward C. Kinzel
Edward C. Kinzel
YLYan Li
Yan Li
SUSreemanth M. Uppuluri
Sreemanth M. Uppuluri
ARArvind Raman
Arvind Raman
XXXianfan Xu
Xianfan Xu
Ridge nanoscale aperture antennas have been shown to be a high transmission nanoscale light source. They provide a small, polarization-dependent near-field optical spot with much higher transmission efficiency than circularly-shaped apertures with similar field confinement. This provides significant motivations to understand the electromagnetic fields in the immediate proximity to the apertures. This paper describes an experimental three-dimensional optical near-field mapping of a bowtie nano-aperture. The measurements are performed using a home-built near-field scanning optical microscopy (NSOM) system. An aluminum coated Si3N4 probe with a 150 nm hole at the tip is used to collect optical signals. Both contact and constant-height scan (CHS) modes are used to measure the optical intensity at different longitudinal distances. A force-displacement curve is used to determine the tip-sample separation distance allowing the optical intensities to be mapped at distances as small as 50 nm and up to micrometer level. The experimental results also demonstrate the polarization dependence of the transmission through the bowtie aperture. Numerical simulations are also performed to compute the aperture’s electromagnetic near-field distribution and are shown to agree with the experimental results.

4 May 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YLYanzhang Li
Yanzhang Li
RGRui Guo
Rui Guo
YWYuChen Wang
YuChen Wang
JMJingzhong Ma
Jingzhong Ma
XMXin Miao
Xin Miao
DJDong Jiang
Dong Jiang
Chronic lateral ankle instability (CLAI) is commonly secondary to prior lateral ankle ligament injury, and the concomitant latent syndesmosis injury would prolong recovery time and increase the risk of substantial traumatic arthritis. However, differentiating syndesmotic injury from isolated lateral ankle ligament injury in CLAI cases is difficult by conventional physical and radiological examinations. To improve the accuracy of syndesmotic injury diagnosis, a shoe-integrated sensor system (SISS) is proposed. This system measures plantar pressure during walking to detect the presence of syndesmotic injury. The study included 27 participants who had ankle sprains and underwent an examination. Plantar pressure in eight regions of interest was measured for both limbs, and syndesmotic injuries were examined using arthroscopy. The width of the syndesmosis was measured to evaluate its severity. The characteristics of plantar pressure were compared between patients with normal and injured syndesmosis. The results indicated that peak plantar pressure ratios with logistic regression predicted value > 0.51 accurately distinguished concomitant syndesmotic injury during walking, with high sensitivity (80%) and specificity (75%). The post-test probability of having a syndesmotic injury was positively 80% and negatively 25%. These findings demonstrate the effectiveness of cost-effective wearable sensors in objectively diagnosing concomitant syndesmotic injuries in cases of CLAI.