29 September 2021 in IEEE Sensors Journal
In clinical, the center of pressure (CoP) is commonly used for accessing the stability of a person’s postural control, which is highly associated with various neurological diseases and movement disorders such as Alzheimer’s disease, Parkinson’s disease, chronic ankle instability. Such a disease usually has a long development or rehabilitation process which requires long-term CoP monitoring. The current CoP evaluation process does not meet the requirement, as it is often complicated and expensive through either the lab-based equipment or the clinical evaluation procedure. Different wearable sensor-based systems with less cost and restrictions have emerged, but their way of CoP calculation requires deliberate calibration of the positions of their sensors, which are not feasible in daily CoP monitoring. In this study, we developed a long-term CoP monitoring system in a smart-shoe form. First, a thin and flexible smart insole with optimal sensor locations was designed to be compact and energy sufficient for a whole-day usage. Then, a user-friendly app on the smartphone with a cloud-based data managing system was developed for applications in both clinical and home environments. Additionally, a simplified CoP estimation model was created without the need for calibration. Lastly, a machine learning-based human activity recognition method was incorporated to make the CoP detection process more automatic. Through a thorough validation test with the clinical level lab equipment, our system can generate the CoP measurements with high accuracy.
24 February 2010 in Optics Express
Ridge nanoscale aperture antennas have been shown to be a high transmission nanoscale light source. They provide a small, polarization-dependent near-field optical spot with much higher transmission efficiency than circularly-shaped apertures with similar field confinement. This provides significant motivations to understand the electromagnetic fields in the immediate proximity to the apertures. This paper describes an experimental three-dimensional optical near-field mapping of a bowtie nano-aperture. The measurements are performed using a home-built near-field scanning optical microscopy (NSOM) system. An aluminum coated Si3N4 probe with a 150 nm hole at the tip is used to collect optical signals. Both contact and constant-height scan (CHS) modes are used to measure the optical intensity at different longitudinal distances. A force-displacement curve is used to determine the tip-sample separation distance allowing the optical intensities to be mapped at distances as small as 50 nm and up to micrometer level. The experimental results also demonstrate the polarization dependence of the transmission through the bowtie aperture. Numerical simulations are also performed to compute the aperture’s electromagnetic near-field distribution and are shown to agree with the experimental results.