Jorge Romero Domínguez

Jorge Romero Domínguez

Auto-generated profile, based on publicly available information

Jorge Romero Domínguez

Material Science and Engineering Program Physical Science and Engineering Division King Abdullah University of Science and Technology (KAUST) Thuwal 23955–6900 Saudi Arabia

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2025 in Advanced Functional Materials
Verified
Journal Article
Open access
WGWejdan S. Al Ghamdi
Wejdan S. Al Ghamdi
JDJorge Romero Domínguez
Jorge Romero Domínguez
EHErol Hasan
Erol Hasan
TMTemur Maksudov
Temur Maksudov
TAThomas D. Anthopoulos
Thomas D. Anthopoulos
DADana Alsulaiman
Dana Alsulaiman
Miniaturized, reusable, and scalable biosensors are key enablers of precision diagnostics and accessible healthcare. Among emerging liquid biopsy cancer biomarkers, microRNAs (miRNAs) have demonstrated transformative potential; however, conventional detection methods rely on expensive enzymes, labels, and bulky instrumentation, limiting clinical utility. Field effect transistor (FET) biosensors offer a promising alternative owing to their miniaturized size, intrinsic amplification capacity, user‐friendliness, and scalability. This study introduces a probe‐functionalized thin film transistor‐based miRNA biosensor, called miR‐TFT, enabling label‐free, enzyme‐free, ultrasensitive, and specific detection of miRNA. The highly scalable device features a tri‐channel heterojunction thin‐film transistor (HJ‐TFT) with an In 2 O 3 /ZnO channel, functionalized with bespoke peptide nucleic acid (PNA) probes via phosphonic acid anchor groups. Compared to conventional oligonucleotides, PNAs offer superior specificity, stability, and resistance to degradation. Sequence‐specific binding between the target miRNA and PNA probes induces charge modulation at the buried heterointerface, altering the transistor's electrical properties. This interaction produces an amplified signal, yielding an ultra‐low 0.6 fM limit‐of‐detection with single‐nucleotide specificity. Moreover, the device supports facile surface regeneration through O 2 plasma treatment, enabling device reuse without compromising performance. In addition to its exceptional analytical performance, miR‐TFT offers portability, reusability, and compatibility with wafer‐scale manufacturing, positioning it as a transformative solution to drive decentralized precision diagnostics.