19 August 2024 in IEEE Sensors Journal
Blood pressure (BP), as a key indicator, reflects the health status of the cardiovascular system. To address the issue of accurate BP measurement, a BP estimation model based on electrocardiogram (ECG) and photoplethysmography (PPG) and prior information on pulse transit time (PTT) has been proposed. This model features a parallel feature extraction module based on long short-term memory (LSTM) for extracting features and incorporates the prior information PTT through a pre-training strategy. The performance of the model is analyzed using the UCI cuffless BP estimation dataset (UCI-BP) along with correlation analysis, Bland-Altman analysis, and statistical histogram analysis of estimation error. The results show that the mean absolute error (MAE) and standard deviation (SD) for systolic blood pressure (SBP) are 1.02 mmHg and 1.49 mmHg, respectively, and for diastolic blood pressure (DBP) are 3.16 mmHg and 3.74 mmHg, respectively. These results meet the BP standards of the American Association for Medical Devices (AAMI) and the class A standard of the British Hypertension Society (BHS).
15 April 2024 in IEEE Transactions on Industrial Electronics
Fluctuations in blood glucose concentration directly influence the body's internal milieu, resulting in altered bioimpedance characteristics. Recognizing the imperative need of continuous blood glucose monitoring for optimized diabetes care, this article explores a novel, noninvasive method leveraging array bioimpedance and graph neural networks. Concretely, we first extract graph-structured data from bioimpedance measurements using the four-electrode acquisition technology and an array electrode. Then, we propose a differential principal neighborhood aggregation (PNA) graph neural network, which integrates differential computation, positional normalization, and PNA, to process the graph-structured data and solve the problem of blood glucose classification. Finally, we evaluate our system with in vitro agar simulation experiments, with the goal of accurately identifying glucose concentrations from 0 to 10 g/l. Our model achieved 95.32% accuracy, 95.30% precision, and 95.18% recall through five-fold cross validation, which outperforms current graph neural network algorithms, and shows promising potential for practical applications.
13 June 2025 in IEEE Transactions on Instrumentation and Measurement
Non-invasive blood glucose (BG) monitoring using bioelectrical impedance technology holds promise for enhanced BG management. Array electrodes enhance the sensing capability in complex tissues but increase data acquisition time. However, the acquisition time varies significantly across array sizes, with the proposed method showing the acquisition time of a 2 × 2 array is 1.04% of that of a 4 × 4 array. To tackle the challenge, this work proposes an upscaling and reconstruction model (URM) for low-order array impedance data based on electrical impedance tomography (EIT) and a U-shaped autoencoder, with the aim of boosting the information of low-order electrode array data that can be acquired rapidly. An end-to-end glucose concentration classification model based on principal neighbourhood aggregation is also introduced, which incorporates a natural feature extraction module that supplements the feature information of low-order array data, and a multi-scale constraint method to balance the intermediate training process. The proposed model is validated through EIT simulations, achieving an image similarity score of 0.93 for the URM. Additionally, validation using a biological tissue simulator yielded a classification accuracy of 90.82% precise of 90.85%, recall of 90.79% and F1 score of 90.77%.