Gianluca Janka

Gianluca Janka

Auto-generated profile, based on publicly available information

Gianluca Janka

PSI Center for Neutron and Muon Sciences CNM 5232 Villigen PSI Switzerland

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2022 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
BOBen Ohayon
Ben Ohayon
GJG. Janka
G. Janka
ICI. Cortinovis
I. Cortinovis
ZBZ. Burkley
Z. Burkley
LBL. de Sousa Borges
L. de Sousa Borges
MCMu-MASS Collaboration
Mu-MASS Collaboration
We report a new measurement of the n=2 Lamb shift in Muonium. Our result of 1047.2(2.3)stat(1.1)syst  MHz comprises an order of magnitude improvement upon the previous best measurement. This value matches the theoretical calculation within 1 standard deviation allowing us to set limits on Lorentz and CPT violation in the muonic sector, as well as on new physics coupled to muons and electrons which could provide an explanation of the muon g−2 anomaly.

25 July 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
PBP. Blumer
P. Blumer
MCM. Charlton
M. Charlton
MCM. Chung
M. Chung
PCP. Cladé
P. Cladé
PCP. Comini
P. Comini
CBC.J. Baker
C.J. Baker

1 April 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
LGLars Gerchow
Lars Gerchow
SBSayani Biswas
Sayani Biswas
GJGianluca Janka
Gianluca Janka
CVCarlos Vigo
Carlos Vigo
AKAndreas Knecht
Andreas Knecht
AAAlex Amato
Alex Amato
The usage of muonic x-rays to study elemental properties like nuclear radii ranges back to the seventies. This triggered the pioneering work at the Paul Scherrer Institute (PSI), during the eighties on the Muon-induced x-ray emission (MIXE) technique for a non-destructive assessment of elemental compositions. In recent years, this method has seen a rebirth, improvement, and adoption at most muon facilities around the world. Hereby, the PSI offers unique capabilities with its high-rate continuous muon beam at the Swiss Muon Source (SμS). We report here the decision-making, construction, and commissioning of a dedicated MIXE spectrometer at PSI, the GermanIum Array for Non-destructive Testing (GIANT) setup. Multiple campaigns highlighted the outstanding capabilities of MIXE at PSI, e.g., resolving down to 1 at. % elemental concentrations with as little as 1 h data taking, measuring isotopic ratios for elements from iron to lead, and characterizing gamma rays induced by muon nuclear capture. On-target beam spots were characterized with a dedicated charged particle tracker to be symmetric to 5% with an average σ = 22.80(25) and 14.41(8) mm for 25 and 45 MeV/c, respectively. Advanced analysis of the high-purity germanium signals further allows us to improve energy and timing resolutions to ∼1 keV and 20 ns at 1 MeV, respectively. Within the GIANT setup, an average detector has a photopeak efficiency of ϵĒ=0.11 % and an energy resolution of σĒ=0.8keV at E = 1000 keV. The overall performance of the GIANT setup at SμS allowed us to start a rich user program with archaeological samples, Li-ion battery research, and collaboration with the industry. Future improvements will include a simulation-based analysis and a higher degree of automation, e.g., automatic scans of a series of muon momenta and automatic sample changing.

25 November 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
GJGianluca Janka
Gianluca Janka
BOBen Ohayon
Ben Ohayon
ICIrene Cortinovis
Irene Cortinovis
ZBZak Burkley
Zak Burkley
LBLucas de Sousa Borges
Lucas de Sousa Borges
PCPaolo Crivelli
Paolo Crivelli
Muons are puzzling physicists since their discovery when they were first thought to be the meson predicted by Yukawa to mediate the strong force. The recent result at Fermilab on the muon g-2 anomaly puts the muonic sector once more under the spotlight and calls for further measurements with this particle. Here, we present the results of the measurement of the 2S1/2, F = 0 → 2P1/2, F = 1 transition in Muonium. The measured value of 580.6(6.8) MHz is in agreement with the theoretical calculations. A value of the Lamb shift of 1045.5(6.8) MHz is extracted, compatible with previous experiments. We also determine the 2S hyperfine splitting in Muonium to be 559.6(7.2) MHz. The measured transition being isolated from the other hyperfine levels holds the promise to provide an improved determination of the Muonium Lamb shift at a level where bound state QED recoil corrections not accessible in hydrogen could be tested. This result would be sensitive to new physics in the muonic sector, e.g., to new bosons which might provide an explanation of the g-2 muon anomaly and allow to test Lorentz and CPT violation. We also present the observation of Muonium in the n = 3 excited state opening up the possibility of additional precise microwave measurements.

19 April 2023 in The European Physical Journal D
Verified
Journal Article
Open access
PDF file
ICIrene Cortinovis
Irene Cortinovis
BOBen Ohayon
Ben Ohayon
LBLucas de Sousa Borges
Lucas de Sousa Borges
GJGianluca Janka
Gianluca Janka
AGArtem Golovizin
Artem Golovizin
PCPaolo Crivelli
Paolo Crivelli
We present an updated value of the Muonium 1S–2S transition frequency, highlighting contributions from different QED corrections as well as the large uncertainty in the Dirac contribution, stemming from the uncertainty of the electron to muon mass ratio. Improving the measurement of this spectral line would allow to extract a more accurate determination of fundamental constants, such as the electron to muon mass ratio or, combined with the Muonium hyperfine splitting, an independent value of the Rydberg constant. Furthermore, we report on the current status of the Mu-MASS experiment, which aims at measuring the Muonium 1S–2S transition frequency at a $$10\hbox {kHz}$$ 10 kHz uncertainty level. Graphic

12 January 2026 in Applied Physics Letters
Verified
Journal Article
Closed access
AAAkashdeep Akashdeep
Akashdeep Akashdeep
SKSachin Krishnia
Sachin Krishnia
JHJae-Hyun Ha
Jae-Hyun Ha
SASiyeon An
Siyeon An
MGMaik Gaerner
Maik Gaerner
MKMathias Kläui
Mathias Kläui
Ruthenium dioxide (RuO2) has recently emerged as an altermagnetic candidate, but its intrinsic magnetic ground state in thin films remains widely debated. This study aims to clarify the nature and spatial extent of the magnetic order in RuO2 thin films grown under different conditions. Thin films of RuO2 with thicknesses of 30 and 33 nm are deposited by pulsed laser deposition and sputtering onto TiO2(110) and Al2O3(1¯102) substrates, respectively. Low-energy muon spin rotation/relaxation (LE-μSR) with depth-resolved sensitivity measurements is performed in transverse magnetic fields (TF) from 4 K to 290 K. The μSR data collected with a muon implantation energy of 1 keV reveal that magnetic signals originate from the near-surface region of the film (≲10 nm), and the affected volume fraction is approximately 8.5%. The localized magnetic response is consistent across different substrates, growth techniques, and parameter sets, suggesting a common origin related to surface defects and dimensionality effects. The combined use of TF-μSR and the study of depth-dependent implantation with low-energy muons provides direct evidence for surface-confined, inhomogeneous static magnetic order in RuO2 thin films, helping reconcile discrepancies. These findings underscore the importance of considering reduced-dimensional contributions and motivate further investigation into the role of defects, strain, and stoichiometry on the magnetic properties of RuO2, especially at the surface.