Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN) and IN - Institute of Nanoscience and Nanotechnology, Lisbon, Portugal; IBB - Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
Auto-generated profile, based on publicly available information
Denis Issao Santos Ynomoto
Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN) and IN - Institute of Nanoscience and Nanotechnology, Lisbon, Portugal; IBB - Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
Portable, rapid, cost effective and simple analytical tools are in increasing demand to facilitate the routine monitoring of target chemical/biological compounds at the point-of-need. Such devices are highly relevant within the context of food safety, particularly concerning the screening of highly toxic and strictly regulated mycotoxins. To achieve ultrarapid detection of mycotoxins, namely aflatoxin B1, ochratoxin A and deoxynivalenol, at the point-of-need, a novel multiplexed bead-based microfluidic competitive immunosensor, coupled with an array of a-Si:H thin-film photodiodes for integrated fluorescence signal acquisition, is reported. Simultaneously measuring the initial binding rate for each analyte of the sample under analysis against an internal reference, this device provided limits of detection below 1 ng mL−1 for all mycotoxins in a single-step assay and within 1 minute after mixing the sample under analysis with a fluorescent conjugate. The compatibility of the device with the analysis of mycotoxins spiked in corn samples was further demonstrated after performing a sample preparation procedure based on aqueous two-phase extraction. The short times of analysis and sensitivities in the low ng mL−1 range make these devices potentially competitive with the lateral flow devices that are currently the standard for this application. Furthermore, this device architecture and concept is amenable of being expanded to other analytes in food safety, biomedical and other applications.
Thin-film optical transducers integrated in lab-on-a-chip (LoC) devices have the potential to facilitate miniaturization, multiplexing capabilities, portability, and sensitivity. However, there are few systematic studies that provide detailed characterization of these photosensors to particular miniaturized bioassays at reduced light intensities. A more detailed representation of the photosensors performance at low light levels is thus needed in order to improve the engineering of integrated detectors for the next generation of portable biosensors. Here, an assessment of the performance of hydrogenated amorphous silicon (a-Si:H) photosensors, at ultra-low light intensity, based on two different device configurations for integration in a microfluidic platform for biomolecular detection is presented. Both p-i-n photodiodes and parallel contact photoconductors show low dark current density (~10-10 A.cm-2) and photosensitivity comparable with high performing crystalline silicon photosensors. The a-Si:H photosensors were integrated in microfluidic devices for the detection of antibody-horseradish peroxidase conjugates (Ab-HRP) in a chemiluminescence-based assay. Surface concentrations of Ab-HRP as low as ~26 amol.cm-2 and ~9 fmol.cm-2 (corresponding to ~103 and ~106 HRP molecules) were detected with detectors in photodiode and photoconductor configurations, respectively, with the sensitivity of the former being comparable with that of bulky and ultra-sensitive photomultiplier tubes. The excellent sensitivity and dynamic range obtained, together with the miniaturization and arraying potential, highlight the potential of a-Si:H photosensors as an effective means of integrating the multiplexed acquisition of optical data in real time in point-of-need LoC systems.
1 February 2018 in Sensors and Actuators B: Chemical
Label-free approaches to biomolecular detection in microfluidics avoid potential labeling interference, are suitable for the screening of analytes that are not easily tagged, and simplify assay development toward point-of-use applications. In this paper, multimodal label-free detection of biomolecules was performed in a microfluidic system: 1) optically, with an integrated hydrogenated amorphous silicon thin-film photodiode and 2) electrically, using integrated electrochemical impedance interdigitated microelectrodes. Bovine serum albumin, single-stranded DNA, and a mixture of human immunoglobulins G were selected as model biomolecules. The sensitivities of the biomolecular detection were first evaluated in a bare microfluidic channel. The lower limit of detection obtained, for each transducing technique, was 10 nM for the impedimetric detection of ssDNA and 80 nM for the optical detection of a mixture of antibodies. These sensitivities were considered fit-for-purpose when applied to microfluidic systems aimed at monitoring molecular adsorption to different immobilized ligands. To validate the proposed multimodal detection, the model biomolecules were detected in a microfluidic structure packed with ion exchange chromatography agarose microbeads and the target biomolecules were monitored in real time both at bead level and downstream of the packed beads. The application of these label-free sensors ranges from bioprocess optimization to molecular purification and potentially the development of rapid analytics, with the advantages of device compactness, cost effectiveness, high speed of analysis, and multiplexed signal acquisition.