Chronic venous disease of the lower limbs is a highly prevalent pathology and endovenous thermoablation is the technique of choice for treatment of insufficient saphenous veins. However, there is still controversy about the best management for varicose tributaries. This article reports a case of outpatient treatment of reflux of the small saphenous vein and tributary veins in a 52-year-old female patient with post-thrombotic syndrome complaining of pain and edema in the right lower limb. We performed the Transfixing Endovenous Thermal Ablation (TEThA) technique with thermoablation of the small saphenous vein and varicose veins combined with ultrasound-guided administration of 2% polidocanol foam. After 30 days, the control Doppler ultrasound showed occlusion of the short saphenous vein and absence of ultrasound signs of varicose veins and thrombosis. The combined endovenous and perivenous treatment of lower limb varicose veins proved to be safe, fast, and effective.
CHIVA (Cure Conservatrice et Hemodynamique de l'Insuffisance Veineuse en Ambulatoire) is a surgical technique for varicose veins that avoids destroying the saphenous vein and collaterals. In some patients, the flush ligation of saphenous collaterals performed in the CHIVA technique may require more dissection than is desirable. This is especially valid for obese patients and thigh ligations. We report an innovative technique that uses duplex-guided puncture to bring the collateral closer to the skin and reduce the need for dissection and incision. The technique does not change any of the CHIVA principles. While the long-term results are not yet known, we expect them to be similar to normal CHIVA procedures.
Resumo A doença venosa crônica dos membros inferiores possui alta prevalência, com termoablação endovenosa como técnica de escolha para o tratamento de veias safenas insuficientes. Porém, ainda há controvérsia sobre a melhor conduta para as veias tributárias varicosas. Este artigo relata um caso de tratamento ambulatorial de refluxo de veia safena parva e de veias tributárias em paciente do sexo feminino, de 52 anos, com síndrome pós-trombótica e queixa de dor e edema em membro inferior direito. Realizamos a técnica transfixing endovenous thermal ablation (TEThA) com termoablação da veia safena parva e de veias varicosas, combinada com espuma ecoguiada de polidocanol a 2%. Após 30 dias, no eco-Doppler de controle, havia oclusão de veia safena parva e ausência de sinais ecográficos de varizes em face posterior de perna direita e de trombose. O tratamento combinado endovenoso e perivenoso das varizes dos membros inferiores tem se mostrado seguro, rápido e eficaz.
20 August 2026 in Phlebology: The Journal of Venous Disease
Background: Long-pulsed Nd: YAG 1064 lasers are the standard of care for superficial vein transcutaneous laser treatment. The current concept suggests that the larger the laser spot size, the deeper the penetration into the skin for two reasons: First, wider spot sizes allow the use of higher pulse energy, as energy density (Fluence) decreases exponentially as the beam area widens. Second, the same pulse energy delivered by a smaller beam will be concentrated in the surface owing to the scattering effect. In this study, we examine the effect on skin penetration by changing the spot size of a long-pulsed Nd: YAG 1064 nm laser. Methods: 100 different skin samples from 5 human dermolipectomy flaps were shot with 3 consecutive long-pulsed Nd: YAG 1064 nm pulses, one of each with a different spot size (3, 5, and 7 mm), while an energy meter was placed underneath to measure energy. In the first 80 samples, the same total energy (10J) was used for all 240 shots. In the last 20 samples, the same energy density (Fluence) of 100 J/cm2 was used in all 60 shots. Results: No variations in mean energy across all spot sizes were observed (3 mm = 3.85 ± 0.89 J, 5 mm = 4.15 ± 0.83 J, 7 mm = 3.96 ± 0.73 J, p = 0.072). Regardless of the spot size, the average pulse energy attenuation was 60.1% with a standard deviation of 8.3%. The average fluence attenuation was 52.3% with a standard deviation of 5.7%. A strong correlation was found in the final energy measured in the same area, regardless of the spot size used. Conclusion: In an ex vivo human skin model, varying the spot size of a long-pulsed Nd: YAG 1064 nm laser did not significantly affect energy transmission to the subdermal tissue.