Masanori Goto

Masanori Goto

Auto-generated profile, based on publicly available information

Masanori Goto

Department of Neurosurgery, Kobe City Medical Center General Hospital, Kobe, Japan

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
TSTadashi Sunohara
Tadashi Sunohara
HIHirotoshi Imamura
Hirotoshi Imamura
MGM. Goto
M. Goto
RFRyu Fukumitsu
Ryu Fukumitsu
SMS. Matsumoto
S. Matsumoto
NSN. Sakai
N. Sakai
BACKGROUND AND PURPOSE: With the increasing use of the Pipeline Embolization Device for the treatment of aneurysms, predictors of clinical and angiographic outcomes are needed. This study aimed to identify predictors of incomplete occlusion at last angiographic follow-up. MATERIALS AND METHODS: In our retrospective, single-center cohort study, 105 ICA aneurysms in 89 subjects were treated with Pipeline Embolization Devices. Patients were followed per standardized protocol. Clinical and angiographic outcomes were analyzed. We introduced a new morphologic classification based on the included angle of the parent artery against the neck location: outer convexity type (included angle, 200°), and lateral wall type (160° ≤ included angle ≤200°). This classification reflects the metal coverage rate and flow dynamics. RESULTS: Imaging data were acquired in 95.3% of aneurysms persistent at 6 months. Complete occlusion was achieved in 70.5%, and incomplete occlusion, in 29.5% at last follow-up. Multivariable regression analysis revealed that 60 years of age or older (OR, 5.70; P = .001), aneurysms with the branching artery from the dome (OR, 10.56; P = .002), fusiform aneurysms (OR, 10.2; P = .009), and outer convexity–type saccular aneurysms (versus inner convexity type: OR, 30.3; P < .001; versus lateral wall type: OR, 9.71; P = .001) were independently associated with a higher rate of incomplete occlusion at the last follow-up. No permanent neurologic deficits or rupture were observed in the follow-up period. CONCLUSIONS: The aneurysm neck located on the outer convexity is a new, incomplete occlusion predictor, joining older age, fusiform aneurysms, and aneurysms with the branching artery from the dome. No permanent neurologic deficits or rupture was observed in the follow-up, even with incomplete occlusion.


1 April 2024 in Brain Hemorrhages
Verified
Journal Article
Open access
RNRikuo Nishii
Rikuo Nishii
TOTsuyoshi Ohta
Tsuyoshi Ohta
NFNobuyuki Fukui
Nobuyuki Fukui
MKMasaomi Koyanagi
Masaomi Koyanagi
MGMasanori Goto
Masanori Goto
NSNobuyuki Sakai
Nobuyuki Sakai

1 February 2024 in Clinical Neurology and Neurosurgery
Verified
Journal Article
Closed access
YTYuki Takano
Yuki Takano
MKMasaomi Koyanagi
Masaomi Koyanagi
TTTakateru Takamatsu
Takateru Takamatsu
MTMasanori Tokuda
Masanori Tokuda
HTHikari Tomita
Hikari Tomita
TOTsuyoshi Ohta
Tsuyoshi Ohta

11 March 2023 in Heliyon
Verified
Journal Article
Open access
CSChiaki Sakai
Chiaki Sakai
NSNobuyuki Sakai
Nobuyuki Sakai
ATAriel Takayanagi
Ariel Takayanagi
HIHirotoshi Imamura
Hirotoshi Imamura
TOTsuyoshi Ohta
Tsuyoshi Ohta
Satoshi TateshimaSatoshi Tateshima
Satoshi Tateshima
Flow diverter or stent implantation to intracranial target lesion requires large inner diameter microcatheter navigation. The exchange method using stiff long wire is often necessary if it is difficult to navigate over the regular guidewire. However, this method has an intrinsic risk of vessel damage and may cause severe complications. We investigated the safety and efficacy of a new device, the Stabilizer device for navigation in a first-in-human clinical trial under the Certified Review Board agreement. The Stabilizer is a 320 cm length exchange wire with a stent for anchoring and is compatible with a 0.0165" microcatheter. The trial design is a prospective single-arm open-label registry. Inclusion criteria are elective flow diverter treatment or stent-assisted coiling, expected to be difficult to navigate a microcatheter with a regular micro guidewire, and obtained documented consent. The primary endpoint of the study was a hemorrhagic complication. Five patients were enrolled in this trial. The median age is 52 years, ranges from 41 to 70, and all patients were female. Three aneurysms were located on the internal carotid artery, one on the vertebral artery, and one on the basilar artery. Basilar artery aneurysm was treated by stent-assisted coiling and others were treated by flow diverter deployment. All cases successfully navigate microcatheter for the treatment by the trial method using Stabilizer device without any adverse event. The results from this first-in-human consecutive five cases show the safety of the Stabilizer device in neuro-endovascular therapy for navigation of devices to the intracranial target lesion.