1 July 2017 in Journal of Voice
1 January 2012 in Journal of Voice
MMMárcia Helena Moreira Menezes
Márcia Helena Moreira Menezes
1 December 2013 in Optical Engineering
SASergio Lopera Aristizabal
Sergio Lopera Aristizabal
GCGiuseppe Antonio Cirino
ASAparecido Arruda Sobrinho
Aparecido Arruda Sobrinho
+1
This work presents the fabrication of a contiguous Fresnel microlens array (MLA) by employing a low-cost home-built maskless exposure lithographic system based on a digital light projector technology by using Texas Instruments’ digital micromirror device chip. A continuous diffractive phase relief structure was generated on a photoresist-coated silicon wafer, replicated in polydimethylsiloxane (PDMS) and electrostatically bonded to a glass substrate. The whole exposure time takes 10.8 min to expose a MLA, with a resolution of 2.5 μm. This exposure time is relatively short, enabling high throughput or fast prototyping. Optical characterization was carried out using a He-Ne laser source (), by evaluating the maximum intensity of each spot generated at the MLA focal plane, Imax, as well as its sharpness by measuring their full width at half maximum (FWHM) intensity values. The resulting FWHM and maximum intensity spot average values were and , respectively. The quality of replication was evaluated by profile characterization of the resulting mold and replica based on step height measurement along 180 μm. The maximum obtained difference was 32 nm, corresponding to 2.5% of the total mold height or . AFM measurements were also carried out to quantify the roughness quality between mold and replica. The resulting RMS roughness was 4.73 nm () and 6.66 nm () for mold and replica, respectively. A comparison between theoretical and measured intensity profiles at the MLA focal plane was also carried out. A good correspondence between the results was found. Such an MLA can be applied as a Shack–Hartmann wavefront sensor in optical interconnects and to enhance the efficiency of detector arrays.
2 April 2014 in International Archives of Otorhinolaryngology
CICamila Cristina Ishikawa
MTMarystella Tomoe Takahashi
Marystella Tomoe Takahashi
Introduction The study of the dynamic properties of vocal fold vibration is important for understanding the vocal production mechanism and the impact of organic and functional changes. The advent of high-speed videolaryngoscopy (HSV) has provided the possibility of seeing the real cycle of vocal fold vibration in detail through high sampling rate of successive frames and adequate spatial resolution. Objective To describe the technique, advantages, and limitations of using HSV and digital videokymography in the diagnosis of vocal pathologies. Methods We used HSV and digital videokymography to evaluate one normophonic individual and four patients with vocal fold pathologies (nodules, unilateral paralysis of the left vocal fold, intracordal cyst, and adductor spasmodic dysphonia). The vocal fold vibration parameters (glottic closure, vibrational symmetry, periodicity, mucosal wave, amplitude, and glottal cycle phases) were assessed. Results Differences in the vocal vibration parameters were observed and correlated with the pathophysiology. Conclusion HSV is the latest diagnostic tool in visual examination of vocal behavior and has considerable potential to refine our knowledge regarding the vocal fold vibration and voice production, as well as regarding the impact of pathologic conditions have on the mechanism of phonation.
25 April 2011 in Clinical Physiology and Functional Imaging
1 February 2008 in Radiologia Brasileira
MHMaria Aparecida Coelho de Arruda Henry
Maria Aparecida Coelho de Arruda Henry
+3
OBJETIVO: Apresentar um software que permita uma análise detalhada da dinâmica da deglutição. MATERIAIS E MÉTODOS: Participaram deste estudo dez indivíduos após acidente vascular encefálico, sendo seis do gênero masculino, com idade média de 57,6 anos. Foi realizada videofluoroscopia da deglutição e as imagens foram digitalizadas em microcomputador, com posterior análise do tempo do trânsito faríngeo da deglutição, por meio de um cronômetro e do software. RESULTADOS: O tempo médio do trânsito faríngeo da deglutição apresentou-se diferente quando comparados os métodos utilizados (cronômetro e software). CONCLUSÃO: Este software é um instrumento de análise dos parâmetros tempo e velocidade da deglutição, propiciando melhor compreensão da dinâmica da deglutição, com reflexos tanto na abordagem clínica dos pacientes com disfagia como para fins de pesquisa científica.