Yuanzheng Lyu

Yuanzheng Lyu

Auto-generated profile, based on publicly available information

Yuanzheng Lyu

State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DYDachuan Yu
Dachuan Yu
NZNiangcheng Zhou
Niangcheng Zhou
JLJianquan Liao
Jianquan Liao
QWQianggang Wang
Qianggang Wang
YLYuanzheng Lyu
Yuanzheng Lyu
The precise identification of fault locations in multiterminal dc (MTDC) transmission systems using traveling waves (TWs) is imperative for ensuring the secure and stable operation of power systems. The presence of wave impedance discontinuity in overhead-cable hybrid transmission lines (OCHTLs) causes significant changes in TW velocity. Traditional TW-based fault location methods struggle to adapt to these changes. This article introduces an innovative fault location approach tailored for OCHTL, with the primary aim of enhancing fault-ranging accuracy. Initially, a typical OCHTL equivalent model is established, and the propagation characteristics of the OCHTLs’ fault voltage TW (VTW) are analyzed. The variational mode decomposition-Teager energy operator (VMD-TEO) algorithm is then employed to determine the arrival time of the VTW wavefront. To optimize VMD parameters, the Kullback–Leibler (K–L) divergence method is applied, addressing modal aliasing. Additionally, we explore TW velocity attenuation characteristics across segments and introduce a frequency-modified algorithm for faulty segment identification. A high-precision fault location algorithm is then proposed based on two-terminal information, and its robustness and accuracy are validated through simulations using a PSCAD-built MTDC system with OCHTLs.

30 August 2024 in Electric Power Systems Research
Verified
Journal Article
Closed access
YLYuanzheng Lyu
Yuanzheng Lyu
YLYongjie Luo
Yongjie Luo
ZJZan Jia
Zan Jia
SFSihao Fu
Sihao Fu
YTYu Tang
Yu Tang
YZYu Zeng
Yu Zeng

5 February 2025 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
ZXZ. Xuefei
Z. Xuefei
ZNZ. Niancheng
Z. Niancheng
LYL. Yongjie
L. Yongjie
WQW. Qianggang
W. Qianggang
JLJianquan Liao
Jianquan Liao
LYL. Yuanzheng
L. Yuanzheng

24 October 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SFSihao Fu
Sihao Fu
Luona XuLuona Xu
Luona Xu
QWQianggang Wang
Qianggang Wang
Yongjie LuoYongjie Luo
Yongjie Luo
NZNiangcheng Zhou
Niangcheng Zhou
YTYu Tang
Yu Tang
Actively commutated current source converter based high-voltage direct current transmission (CSC-HVDC) with state-of-the-art high power IGCTs is a promising candidate due to its merits such as fault ride-through capability and small footprint. The existing dc fault models of CSC either focus on 3-level CSC topology or neglect the transient process and commutation of the converter after fault, not suitable for accurate dc fault analysis of CSC-HVDC. Moreover, the elimination of ac-filters at the point of common coupling (PCC) will lead to severe PCC voltage distortion of weak-grid connected CSC-HVDC after fault. The interaction between the valve-groups caused by the voltage distortion and its influence on the fault characteristics is yet to be studied. In this article, two dc fault analysis models for CSC-HVDC connected to ac grid with different strengths are proposed. Based on quasi-steady state assumptions and substitution theorem, a simplified model by decoupling the valve-groups at the PCC and its adaptability under different grid strengths are proposed for analytical studies of dc fault. For weak-grid connected CSC-HVDC, a fault analysis model is further derived based on the quantitative analysis of the interaction between valve-groups. The proposed models are validated through PSCAD simulations and HIL experiments.

16 July 2024
Verified
Preprint
Open access
YLYuanzheng Lyu
Yuanzheng Lyu
YLYongjie Luo
Yongjie Luo
ZJZan Jia
Zan Jia
SFSihao Fu
Sihao Fu
YTYu Tang
Yu Tang
YZYu Zeng
Yu Zeng
As offshore wind power development extends into deeper and farther seas, several new AC/DC transmission schemes have been proposed. Each of these schemes has its own technical advantages. However, with the increasing complexity of transmission conditions, selecting the optimal techno-economic transmission system for different scenarios has become an urgent issue that needs to be addressed. Current single-dimension evaluation methods for offshore wind power systems lack comprehensive parameters and sufficient accuracy, making it difficult to accurately select systems for complex operating conditions. To address the above issues, this study first establishes a TLCC-BEP offshore wind power cost indicator that integrates multiple parameters such as water depth and taxes, combined with power generation benefits, environmental, and carbon indicators, proposing a comprehensive benefit evaluation system. Next, the characteristics of the main indicators in the constructed evaluation system are presented based on the results of model sensitivity analysis. Subsequently, using actual scenario GPS data, the VIKOR method based on prospect theory is applied to comprehensively evaluate four schemes—HVAC, FFTS, VSC, and CSC—under multiple conditions, obtaining a more accurate applicability range for each transmission scheme.