7 August 2016 in Journal of Sensors
Attitude estimation is often inaccurate during highly dynamic motion due to the external acceleration. This paper proposes extended Kalman filter-based attitude estimation using a new algorithm to overcome the external acceleration. This algorithm is based on an external acceleration compensation model to be used as a modifying parameter in adjusting the measurement noise covariance matrix of the extended Kalman filter. The experiment was conducted to verify the estimation accuracy, that is, one-axis and multiple axes sensor movement. Five approaches were used to test the estimation of the attitude: (1) the KF-based model without compensating for external acceleration, (2) the proposed KF-based model which employs the external acceleration compensation model, (3) the two-step KF using weighted-based switching approach, (4) the KF-based model which uses thethreshold-basedapproach, and (5) the KF-based model which uses the threshold-based approach combined with a softened part approach. The proposed algorithm showed high effectiveness during the one-axis test. When the testing conditions employed multiple axes, the estimation accuracy increased using the proposed approach and exhibited external acceleration rejection at the right timing. The proposed algorithm has fewer parameters that need to be set at the expense of the sharpness of signal edge transition.
18 February 2019 in Journal of Sensors and Sensor Systems
This paper examines the new study of hand orientation as a substitute for computer-mouse movement and is evaluated based on ISO/TS 9241 part 411: Ergonomics of human–system interaction-evaluation methods for the design of physical input devices. Two pairs of hand-orientation candidates were evaluated, using, for example, pitch–roll and pitch–yaw to substitute for up–down and left–right mouse-cursor movements. The up–down cursor movement was generated from the pitch orientation, while the left–right cursor movement was generated from the roll or yaw orientation, depending on the evaluation of the proposed gesture. The research employed a standard computer mouse as a baseline comparison for the study. The empirical study was conducted to evaluate quantitative performance such as throughput and movement time. The best impression resulted when the throughput had the greatest value as well as the shortest movement time. The performance test was based on Fitts's law using a multi-directional tapping test as suggested by ISO/TS 9241-411. The test was divided into several levels of difficulty, including high, medium, low, and very low. The other assessment is qualitative and was performed using the comfort-rating scale questionnaire and rating of perceived exertion of comfortability and fatigue. The quantitative results show that pitch–yaw throughput is slightly higher than for the pitch–roll gesture, and that the movement time in pitch–yaw is slightly less than in pitch–roll, although there is no statistically significant difference between the two. We also found that pitch–yaw movements have a higher level of comfort based on the comfort-rating scale test. Since the test was divided into levels of difficulty, we identified those gestures suitable for the task with a low and very low level of difficulty based on throughput, movement time, and error-rate results. Finally, this study suggests that pitch–roll and pitch–yaw movements of the hand can be used as substitutes for the mouse, and that pitch–yaw movements are superior in regard to causing less fatigue than pitch–roll movements. Furthermore, this study provides a new suggestion for a suitable level of difficulty when using an inertial sensor as an emulator for the movement of a mouse cursor in the field of human–computer interaction.
1 March 2019 in Journal of Physics: Conference Series
Some disabilities caused by sensory malfunction, accident, or congenital disorder could cause people difficulty in grasping the computer mouse. A well-known substitute uses an inertial sensor to monitor the body's orientation. This paper evaluates the efficiency and effectiveness of different methods of holding the sensor. There are two modes of holding the sensor, the grasping mode and the attached mode; we also evaluate a mouse as a baseline. The attached mode works by placing the sensor on the back of user's hand. The quantitative and qualitative evaluation procedure is based on ISO/TS 9241 part 411: Ergonomics of human-system interaction standard. The test consists of four levels of difficulty and indicates that the throughput and task completion times were not statistically different between grasping and attached mode. We also found that grasping mode and attached mode did not show significantly statistical differences in comfort and fatigue based on the questionnaires. The results also suggest that the orientation of the hand used in grasping and attached modes is suitable only for lower-impact computer use.