27 September 2022 in Circulation: Arrhythmia and Electrophysiology
Background: Pulsed field ablation (PFA) is a novel energy modality for treatment of cardiac arrhythmias. The impact of electrode-tissue proximity on lesion formation by PFA has not been conclusively assessed. The objective of this investigation was to evaluate the effects of electrode-tissue proximity on cardiac lesion formation with a biphasic, bipolar PFA system. Methods: PFA was delivered on the ventricular epicardial surface in an isolated porcine heart model (n=8) via a 4-electrode prototype catheter. An offset tool was designed to control the distance between electrodes and target tissue; deliveries were placed 0 mm (0 mm offset), 2 mm (2 mm offset), and 4 mm away from the tissue (4 mm offset). Lesions were assessed using tetrazolium chloride staining. Numerical models for the experimental setup with and without the offset tool validated and supported results. Results: Cardiac lesion dimensions decreased proportional to the distance between epicardial surface and electrodes. Lesion depth averaged 4.3±0.4 mm, 2.7±0.4 mm, and 1.3±0.4 mm for the 0, 2, and 4 mm and lesion width averaged 9.4±1.1 mm, 7.5±0.8 mm and 5.8±1.4 mm for the 0, 2, and 4 mm offset distances, respectively. Numerical modeling matched ex vivo results well and predicted lesion creation with and without the offset tool. Conclusions: Using a biphasic, bipolar PFA system resulted in cardiac lesions even in the 0 mm offset distance case. The relationship between lesion depth and offset distance was linear, and the deepest lesions were created with 0 mm offset distance, that is, with electrodes in contact with tissue. Therefore, close electrode-tissue proximity increases the likelihood of achieving transmural lesions by maximizing the electric field penetration into the target tissue.
2 March 2021 in Journal of Cardiovascular Electrophysiology
Background: Pulsed field ablation (PFA) has been identified as an alternative to thermal‐based ablation systems for treatment of atrial fibrillation patients. The objective of this Good Laboratory Practice (GLP) study was to characterize the chronic effects and safety of overlapping lesions created by a PFA system at intracardiac locations in a porcine model.Methods: A circular catheter with nine gold electrodes was used for overlapping low‐ or high‐dose PFA deliveries in the superior vena cava (SVC), right atrial appendage (RAA), and right superior pulmonary vein (RSPV) in six pigs. Electrical isolation was evaluated acutely and chronic lesions were assessed via necropsy and histopathology after 4‐week survival. Acute and chronic safety data were recorded peri‐ and post‐procedurally.Results: No animal experienced ventricular arrhythmia during PFA delivery, and there was no evidence of periprocedural PFA‐related adverse events. Lesions created in all anatomies resulted in electrical isolation postprocedure. Lesions were circumferential, contiguous, and transmural, with all converting into consistent lines of chronic replacement fibrosis, regardless of trabeculated or smooth endocardial surface structure. Ablations were non‐thermally generated with only minimal post‐delivery temperature rises recorded at the electrodes. There was no evidence of extracardiac damage, stenosis, aneurysms, endocardial disruption, or thrombus.Conclusion: PFA deliveries to the SVC, RAA, and RSPV resulted in complete circumferential replacement fibrosis at 4‐week postablation with an excellent chronic myocardial and collateral tissue safety profile. This GLP study evaluated the safety and efficacy of a dosage range in preparation for a clinical trial and characterized the non‐thermal nature of PFA.
1 September 2020 in Circulation: Arrhythmia and Electrophysiology
Background: Pulmonary vein (PV) stenosis is a highly morbid condition that can result after catheter ablation for PV isolation. We hypothesized that pulsed field ablation (PFA) would reduce PV stenosis risk and collateral injury compared with irrigated radiofrequency ablation (IRF). Methods: IRF and PFA deliveries were randomized in 8 dogs with 2 superior PVs ablated using one technology and 2 inferior PVs ablated using the other technology. IRF energy (25–30 W) or PFA was delivered (16 pulse trains) at each PV in a proximal and in a distal site. Contrast computed tomography scans were collected at 0, 2, 4, 8, and 12-week (termination) time points to monitor PV cross-sectional area at each PV ablation site. Results: Maximum average change in normalized cross-sectional area at 4-weeks was −46.1±45.1% post-IRF compared with −5.5±20.5% for PFA ( P ≤0.001). PFA-treated targets showed significantly fewer vessel restrictions compared with IRF ( P ≤0.023). Necropsy showed expansive PFA lesions without stenosis in the proximal PV sites, compared with more confined and often incomplete lesions after IRF. At the distal PV sites, only IRF ablations were grossly identified based on focal fibrosis. Mild chronic parenchymal hemorrhage was noted in 3 left superior PV lobes after IRF. Damage to vagus nerves as well as evidence of esophagus dilation occurred at sites associated with IRF. In contrast, no lung, vagal nerve, or esophageal injury was observed at PFA sites. Conclusions: PFA significantly reduced risk of PV stenosis compared with IRF postprocedure in a canine model. IRF also caused vagus nerve, esophageal, and lung injury while PFA did not.
1 June 2022 in Circulation: Arrhythmia and Electrophysiology
Background: Phrenic nerve palsy is a well-known complication of cardiac ablation, resulting from the application of direct thermal energy. Emerging pulsed field ablation (PFA) may reduce the risk of phrenic nerve injury but has not been well characterized. Methods: Accelerometers and continuous pacing were used during PFA deliveries in a porcine model. Acute dose response was established in a first experimental phase with ascending PFA intensity delivered to the phrenic nerve (n=12). In a second phase, nerves were targeted with a single ablation level to observe the effect of repetitive ablations on nerve function (n=4). A third chronic phase characterized assessed histopathology of nerves adjacent to ablated cardiac tissue (n=6). Results: Acutely, we observed a dose-dependent response in phrenic nerve function including reversible stunning (R 2 =0.965, P <0.001). Furthermore, acute results demonstrated that phrenic nerve function responded to varying levels of PFA and catheter proximity placements, resulting in either: no effect, effect, or stunning. In the chronic study phase, successful isolation of superior vena cava at a dose not predicted to cause phrenic nerve dysfunction was associated with normal phrenic nerve function and normal phrenic nerve histopathology at 4 weeks. Conclusions: Proximity of the catheter to the phrenic nerve and the PFA dose level were critical for phrenic nerve response. Gross and histopathologic evaluation of phrenic nerves and diaphragms at a chronic time point yielded no injury. These results provide a basis for understanding the susceptibility and recovery of phrenic nerves in response to PFA and a need for appropriate caution in moving beyond animal models.
1 November 2022 in Circulation: Arrhythmia and Electrophysiology
Background: Irreversible electroporation is an energy form utilizing high-voltage pulsed electric field, leading to cellular homeostasis disruption and cell death. Recently, irreversible electroporation has shown promising results for the treatment of cardiac arrhythmias. However, reversible and irreversible effects of pulsed electric field on cardiac myocytes remain poorly understood. Here, we evaluated the influence of a monophasic single electric pulse (EP) on the contractility, Ca 2+ homeostasis and recovery of cardiac myocytes. Methods: Isolated rat left ventricular myocytes were electroporated using single monophasic EP of different durations and voltages. Sarcomere length and intracellular Ca 2+ were simultaneously monitored for up to 20 minutes after EP application in Fura-2 loaded left ventricular myocytes. Lethal voltage thresholds were determined using 100 µs and 10 ms pulses and by discriminating cell orientation with respect to the electric field. Results: Electroporation led to an immediate increase in intracellular Ca 2+ which was dependent upon the voltage delivered to the cell. Intermediate-voltage EP (140 V, 100 µs) increased sarcomere shortening, Ca 2+ transient amplitude, and diastolic Ca 2+ level measured 1 minute post-EP. Although sarcomere shortening returned to pre-EP level within 5 minutes, Ca 2+ transient amplitude decreased further below pre-EP level and diastolic Ca 2+ level remained elevated within 20 minutes post-EP. Spontaneous contractions were observed after sublethal EP application but their frequency decreased progressively within 20 minutes. Lethal EP voltage threshold was lower in myocytes oriented perpendicular than parallel to the electric field using 100 µs pulses while an opposite effect was found using 10 ms pulses. Conclusions: Sublethal EP affected rat left ventricular myocytes contractility and disrupted Ca 2+ homeostasis as a function of the EP voltage. Moreover, EP-induced lethality was preceded by a large increase in intracellular Ca 2+ and was dependent upon the EP duration, amplitude and left ventricular myocytes orientation with respect to the electric field. These findings provide new insights into the effect of pulsed electric field on cardiac myocytes.