Alexis Morgan

Alexis Morgan

Auto-generated profile, based on publicly available information

Alexis Morgan

National Heart and Lung Institute, Imperial College London, London, United Kingdom

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2024 in Science Advances
Verified
Journal Article
Open access
RXRuoxiao Xie
Ruoxiao Xie
YCYuanxiong Cao
Yuanxiong Cao
RSRujie Sun
Rujie Sun
RWRichard Wang
Richard Wang
AMAlexis Morgan
Alexis Morgan
MSMolly M. Stevens
Molly M. Stevens
3D soft bioscaffolds have great promise in tissue engineering, biohybrid robotics, and organ-on-a-chip engineering applications. Though emerging three-dimensional (3D) printing techniques offer versatility for assembling soft biomaterials, challenges persist in overcoming the deformation or collapse of delicate 3D structures during fabrication, especially for overhanging or thin features. This study introduces a magnet-assisted fabrication strategy that uses a magnetic field to trigger shape morphing and provide remote temporary support, enabling the straightforward creation of soft bioscaffolds with overhangs and thin-walled structures in 3D. We demonstrate the versatility and effectiveness of our strategy through the fabrication of bioscaffolds that replicate the complex 3D topology of branching vascular systems. Furthermore, we engineered hydrogel-based bioscaffolds to support biohybrid soft actuators capable of walking motion triggered by cardiomyocytes. This approach opens new possibilities for shaping hydrogel materials into complex 3D morphologies, which will further empower a broad range of biomedical applications.

1 September 2023 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
NSNicolas Steenbergen
Nicolas Steenbergen
IBIvan Busha
Ivan Busha
AMAlexis Morgan
Alexis Morgan
CMCollin Mattathil
Collin Mattathil
APArieh Levy Pinto
Arieh Levy Pinto
Rylie A.  GreenRylie A. Green
Rylie A. Green
Conventional wet Ag/AgCl electrodes are widely used in electrocardiography, electromyography (EMG), and electroencephalography (EEG) and are considered the gold standard for biopotential measurements. However, these electrodes require substantial skin preparation, are single use, and cannot be used for continuous monitoring (>24 h). For these reasons, dry electrodes are preferable during surface electromyography (sEMG) due to their convenience, durability, and longevity. Dry conductive elastomers (CEs) combine conductivity, flexibility, and stretchability. In this study, CEs combining poly(3,4-ehtylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS) in polyurethane are explored as dry, skin contacting EMG electrodes. This study compares these CE electrodes to commercial wet Ag/AgCl electrodes in five subjects, classifying four movements: open hand, fist, wrist extension, and wrist flexion. Classification accuracy is tested using a backpropagation artificial neural network. The control Ag/AgCl electrodes have a 98.7% classification accuracy, while the dry conductive elastomer electrodes have a classification accuracy of 99.5%. As a conclusion, PEDOT based dry CEs were shown to successfully function as on-skin electrodes for EMG recording, matching the performance of Ag/AgCl electrodes, while addressing the need for minimal skin prep, no gel, and wearable technology.

1 May 2023
Verified
Conference Paper
Closed access
RSRajiv Nagin Shah
Rajiv Nagin Shah
AMA.D. Morgan
A.D. Morgan
PGP.M. George
P.M. George
JQJennifer Kathleen Quint
Jennifer Kathleen Quint