Chi Leng Leong

Chi Leng Leong

Auto-generated profile, based on publicly available information

Chi Leng Leong

Department of Bioengineering, Imperial College, London, UK

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
ANAdrian Nightingale
Adrian Nightingale
CLChi Leng Leong
Chi Leng Leong
RBRachel A. Burnish
Rachel A. Burnish
SHSammer Ul Hassan
Sammer Ul Hassan
YZYu Zhang
Yu Zhang
XNXize Niu
Xize Niu
Knowing how biomarker levels vary within biological fluids over time can produce valuable insight into tissue physiology and pathology, and could inform personalised clinical treatment. We describe here a wearable sensor for monitoring biomolecule levels that combines continuous fluid sampling with in situ analysis using wet-chemical assays (with the specific assay interchangeable depending on the target biomolecule). The microfluidic device employs a droplet flow regime to maximise the temporal response of the device, using a screw-driven push-pull peristaltic micropump to robustly produce nanolitre-sized droplets. The fully integrated sensor is contained within a small (palm-sized) footprint, is fully autonomous, and features high measurement frequency (a measurement every few seconds) meaning deviations from steady-state levels are quickly detected. We demonstrate how the sensor can track perturbed glucose and lactate levels in dermal tissue with results in close agreement with standard off-line analysis and consistent with changes in peripheral blood levels.

22 October 2016 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Open access
MRMichelle L Rogers
Michelle L Rogers
CLChi Leng Leong
Chi Leng Leong
SGSally An Gowers
Sally An Gowers
ISIsabelle C Samper
Isabelle C Samper
SJSharon L Jewell
Sharon L Jewell
MBMartyn G Boutelle
Martyn G Boutelle
Spreading depolarizations occur spontaneously and frequently in injured human brain. They propagate slowly through injured tissue often cycling around a local area of damage. Tissue recovery after an spreading depolarization requires greatly augmented energy utilisation to normalise ionic gradients from a virtually complete loss of membrane potential. In the injured brain, this is difficult because local blood flow is often low and unreactive. In this study, we use a new variant of microdialysis, continuous on-line microdialysis, to observe the effects of spreading depolarizations on brain metabolism. The neurochemical changes are dynamic and take place on the timescale of the passage of an spreading depolarization past the microdialysis probe. Dialysate potassium levels provide an ionic correlate of cellular depolarization and show a clear transient increase. Dialysate glucose levels reflect a balance between local tissue glucose supply and utilisation. These show a clear transient decrease of variable magnitude and duration. Dialysate lactate levels indicate non-oxidative metabolism of glucose and show a transient increase. Preliminary data suggest that the transient changes recover more slowly after the passage of a sequence of multiple spreading depolarizations giving rise to a decrease in basal dialysate glucose and an increase in basal dialysate potassium and lactate levels.

10 April 2013 in ACS Chemical Neuroscience
Verified
Journal Article
Open access
MRMichelle L. Rogers
Michelle L. Rogers
DFDelphine Feuerstein
Delphine Feuerstein
CLChi Leng Leong
Chi Leng Leong
MTMasatoshi Takagaki
Masatoshi Takagaki
XNXize Niu
Xize Niu
MBMartyn G. Boutelle
Martyn G. Boutelle
Microfluidic glucose biosensors and potassium ion selective electrodes were used in an in vivo study to measure the neurochemical effects of spreading depolarizations (SD), which have been shown to be detrimental to the injured human brain. A microdialysis probe implanted in the cortex of rats was connected to a microfluidic PDMS chip containing the sensors. The dialysate was also analyzed using our gold standard, rapid sampling microdialysis (rsMD). The glucose biosensor performance was validated against rsMD with excellent results. The glucose biosensors successfully monitored concentration changes, in response to SD wave induction, in the range of 10–400 μM with a second time-resolution. The data show that during a SD wave, there is a time delay of 62 ± 24.8 s (n = 4) between the onset of the increase in potassium and the decrease in glucose. This delay can be for the first time demonstrated, thanks to the high-temporal resolution of the microfluidic sensors sampling from a single tissue site (the microdialysis probe), and it indicates that the decrease in glucose is due to the high demand of energy required for repolarization.

28 November 2013 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
RKRaghuram Reddy Kothur
Raghuram Reddy Kothur
JHJessica Hall
Jessica Hall
BPBhavik Anil Patel
Bhavik Anil Patel
CLChi Leng Leong
Chi Leng Leong
MBMartyn G. Boutelle
Martyn G. Boutelle
Peter CraggPeter Cragg
Peter Cragg
An esterified pillar[5]arene, incorporated into a PVC membrane, displays a non-Nernstian response to changes in pH.

30 October 2017 in Analytical Chemistry
Verified
Journal Article
Closed access
MBMarsilea A. Booth
Marsilea A. Booth
SGSally A. N. Gowers
Sally A. N. Gowers
CLChi Leng Leong
Chi Leng Leong
MRMichelle L. Rogers
Michelle L. Rogers
ISIsabelle C. Samper
Isabelle C. Samper
MBMartyn G. Boutelle
Martyn G. Boutelle

10 July 2019 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
SGSally A. N. Gowers
Sally A. N. Gowers
MRMichelle L. Rogers
Michelle L. Rogers
MBMarsilea A. Booth
Marsilea A. Booth
CLChi L. Leong
Chi L. Leong
ISIsabelle C. Samper
Isabelle C. Samper
MBMartyn G. Boutelle
Martyn G. Boutelle
Modular platform providing the building blocks to translate specialised microfluidics from the laboratory to a clinical environment.