Christopher Mark Lund

Christopher Mark Lund

Auto-generated profile, based on publicly available information

Christopher Mark Lund

McGill University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
LMLogan Montgomery
Logan Montgomery
CLChristopher Mark Lund
Christopher Mark Lund
ALAnthony Landry
Anthony Landry
JKJohn Kildea
John Kildea
Neutron exposure poses a unique radiation protection concern because neutrons have a large, energy-dependent relative biological effectiveness (RBE) for stochastic effects. Recent computational studies on the microdosimetric properties of neutron dose deposition have implicated clustered DNA damage as a likely contributor to this marked energy dependence. So far, publications have focused solely on neutron RBE for inducing clusters of DNA damage containing two or more DNA double strand breaks (DSBs). In this study, we have conducted a novel assessment of neutron RBE for inducing all types of clustered DNA damage that contain two or more lesions, stratified by whether the clusters contain DSBs (complex DSB clusters) or not (non-DSB clusters). This assessment was conducted for eighteen initial neutron energies between 1 eV and 10 MeV as well as a reference radiation of 250 keV x-rays. We also examined the energy dependence of cluster length and cluster complexity because these factors are believed to impact the DNA repair process. To carry out our investigation, we developed a user-friendly TOPAS-nBio application that includes a custom nuclear DNA model and a novel algorithm for recording clustered DNA damage. We found that neutron RBE for inducing complex DSB clusters exhibited similar energy dependence to the canonical neutron RBE for stochastic radiobiological effects, at multiple depths in human tissue. Qualitatively similar results were obtained for non-DSB clusters, although the quantitative agreement was lower. Additionally we identified a significant neutron energy dependence in the average length and complexity of clustered lesions. These results support the idea that many types of clustered DNA damage contribute to the energy dependence of neutron RBE for stochastic radiobiological effects and imply that the size and constituent lesions of individual clusters should be taken into account when modeling DNA repair. Our results were qualitatively consistent for (i) multiple radiation doses (including a low-dose 0.1 Gy irradiation), (ii) variations in the maximal lesion separation distance used to define a cluster, and (iii) two distinct collections of physics models used to govern particle transport. Our complete TOPAS-nBio application has been released under an open-source license to enable others to independently validate our work and to expand upon it.

1 May 2020 in Physica Medica
Verified
Journal Article
Closed access
CLC.M. Lund
C.M. Lund
GFG. Famulari
G. Famulari
LML. Montgomery
L. Montgomery
JKJohn Kildea
John Kildea

4 October 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
JBJulien Bancheri
Julien Bancheri
ACAndrew Currell
Andrew Currell
AKAnatoly Krasnykh
Anatoly Krasnykh
MMMorgan Maher
Morgan Maher
CLChristopher Lund
Christopher Lund
JSJan Seuntjens
Jan Seuntjens

10 January 2025 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
CLChristopher M. Lund
Christopher M. Lund
PJPaul M. Jung
Paul M. Jung
MMMorgan J. Maher
Morgan J. Maher
JBJulien Bancheri
Julien Bancheri
TPThomas Planche
Thomas Planche
JSJan Seuntjens
Jan Seuntjens
Proton therapy presents an interesting and important challenge to accelerator physics. Practical restrictions such as room size, gantry weight, and cost have led to a demand for more compact and affordable devices. Success would benefit a significant number of patients every year. Dielectric wall accelerators could provide this breakthrough, but there is limited work available regarding their feasibility or possible integration into medical devices, and no solutions exist for longitudinal beam control. In this work, we discuss the development of a linear beam dynamics model for dielectric wall accelerators. The model is implemented as part of the open-source code . It is tested against the rf LINAC subroutine in and is used to study bunch injection and transport. Building on recent work, the effect of time-varying fields on beam dynamics is also investigated. Conditions for limiting transverse beam size and maintaining longitudinal stability are discussed, and considerations are given to accelerator and beamline design.

12 May 2025 in Medical Physics
Verified
Journal Article
Open access
MMMorgan J. Maher
Morgan J. Maher
CLChristopher M. Lund
Christopher M. Lund
JBJulien Bancheri
Julien Bancheri
DCDavid G. Cooke
David G. Cooke
JSJan Seuntjens
Jan Seuntjens
Background: Proton therapy (PT) is a beneficial modality for treating certain cancers but remains under utilized due in part to the high cost of existing PT devices. Dielectric wall accelerators (DWAs) are a proposed class of coreless induction accelerators that may present a suitable option for compact and affordable PT. To realize a compact device, acceleration modules must be designed to achieve field strengths approaching 100 MV/m delivered as pulses on the order of nanoseconds. Purpose: Here, we examine pulse injection into radial parallel plate waveguides as a means of producing high‐intensity, pulsed accelerating fields. We present an approach for understanding the impact of waveguide properties on electromagnetic dispersion as well as a means of accounting for this dispersion to produce suitable accelerating fields. Methods: Geometric and material properties for a set of waveguides were identified based on existing literature and commonly available materials. An analytic model is presented to describe how waveguide geometry and material affect electromagnetic dispersion in a waveguide. Simulations performed in COMSOL Multiphysics are used to calculate a transfer function for the set of waveguides, which provide a means of determining the waveguides output for arbitrary inputs and vice versa. The simulation results are compared to the analytic solution and used to explore alternate matching conditions at the beampipe of the accelerator. Results: Overall, radial waveguides provide a passive enhancement of the injected pulse, with enhancement of high‐frequency components found to be proportional to the square root of the ratio of outer radius to inner radius of the waveguide. Dispersion in the waveguide caused by the radial propagation of the pulse depends on multiple waveguide properties (outer radius, inner radius, material) and leads to reduced enhancement at lower frequencies. The field enhancement in the waveguides reduces the peak voltage required to achieve the desired accelerating field strength. However, dispersion alters the temporal profile of the applied pulse, resulting in a distorted field at the inner radius. Using the transfer function, it is possible to determine the shape of the pulse required to achieve a suitable accelerating field for a given waveguide design. Conclusions: Passive field enhancement occurred in all waveguides and across all frequencies studied in this work. As such, radial parallel plate waveguides could help to reduce the high voltages required from upstream switching networks. The analytic model can be used to select waveguide parameters that provide a suitable enhancement of the upstream voltage pulse to achieve the high field strengths required for a compact accelerator. However, pulse dispersion must be accounted for. If upstream pulse shaping can be achieved to account for electromagnetic dispersion in the waveguide, pulse injection into radial parallel plate waveguides could be a suitable mechanism for field generation in a DWA.

10 September 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
CBChau Giang Bui
Chau Giang Bui
CLChristopher M Lund
Christopher M Lund
JNJamiel Nasser
Jamiel Nasser
MMMorgan Maher
Morgan Maher
JBJulien Bancheri
Julien Bancheri
JSJan Seuntjens
Jan Seuntjens
Objective. The dielectric wall accelerator (DWA) is proposed as a low-cost, compact system for proton therapy. It offers additional degrees of freedom over conventional accelerators for controlling beam parameters. This study seeks to determine clinically desirable proton beam characteristics by evaluating their implications for treatment plan quality; particularly, the influence of variations in lateral spot size and beam energy spread were investigated. Approach. A linear optics model of the DWA, developed in TRANSOPTR , was used to define realistic beam parameters at the accelerator exit, from which an analytical method selected those yielding the desired spot sizes and energy spreads at isocenter. These parameters were subsequently passed through a generic nozzle model in TOPAS. Lateral spot size was varied from 1 to 10 mm. Beam energy spread was varied from 0.00005 % and 15 % . Robustly optimized treatment plans were generated in RayStation for a homogeneous water phantom and a sample pediatric central nervous system cancer case. Results were validated against conventional proton beam data. Main results. In the water phantom study, lower energy spreads decreased the normalized surface dose and increased the depth of maximum dose. In both phantom and patient cases, reducing the lateral spot size yielded greater organs-at-risk (OAR) sparing while maintaining comparable target coverage, which is in agreement with the literature. A similar trend of improved OAR sparing was observed with reduced beam energy spread for all cases; albeit, the effect was less pronounced. For realistic optimization of the DWA system, the beam parameters identified as most favorable were a lateral spot size of approximately 1 mm and an energy spread on the order of 0.05 % to 0.5% for 20 to 226 MeV. Significance. These results should prove useful to both hardware and numerical efforts, and form the basis for future studies of the clinical characteristics of prospective DWA machines.