Zhenyue Chen

Zhenyue Chen

Auto-generated profile, based on publicly available information

Zhenyue Chen

Institute of Precision Optical Engineering, School of Physics Science and Engineering, Tongji University, Shanghai, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
ZCZhenyue Chen
Zhenyue Chen
XDXosé Luís Deán-Ben
Xosé Luís Deán-Ben
SGSven Gottschalk
Sven Gottschalk
DRDaniel Razansky
Daniel Razansky
Fluorescent contrast agents are widely employed in biomedical research. While many studies have reported deep tissue imaging of fluorescent moieties using either fluorescence-based or absorption-based (optoacoustic) imaging systems, no systematic comparison has been performed regarding the actual performance of these imaging modalities in detecting deep-seated fluorescent agents. Herein, an integrated imager combining epi-fluorescence and volumetric optoacoustic imaging capabilities has been employed in order to evaluate image degradation with depth for several commonly-used near-infrared dyes in both modes. We performed controlled experiments in tissue-mimicking phantoms containing deeply embedded targets filled with different concentrations of Alexa Fluor 700, Alexa Fluor 750, indocyanine green (ICG) and IRDye 800CW. The results are further corroborated by multi-modal imaging of ICG through mouse tissues in vivo. It is shown that optoacoustics consistently provides better sensitivity in differentiating fluorescent targets located at depths beyond 2 mm in turbid tissues, as quantified by evaluating image contrast, signal to noise ratio and spatial resolution performance.

10 December 2021 in Science Advances
Verified
Journal Article
Open access
HEHector Estrada
Hector Estrada
JRJustine Robin
Justine Robin
AÖAli Özbek
Ali Özbek
ZCZhenyue Chen
Zhenyue Chen
AMAnne Marowsky
Anne Marowsky
DRDaniel Razansky
Daniel Razansky
Precision targeting and monitoring of preclinical focused ultrasound enabled by fluorescence-guided transcranial ultrasound.

7 July 2022 in Advanced Science
Verified
Journal Article
Open access
ZCZhenyue Chen
Zhenyue Chen
QZQuanyu Zhou
Quanyu Zhou
XDXosé Luís Deán‐Ben
Xosé Luís Deán‐Ben
IGIrmak Gezginer
Irmak Gezginer
RNRuiqing Ni
Ruiqing Ni
DRDaniel Razansky
Daniel Razansky
Modern optical neuroimaging approaches are expanding the ability to elucidate complex brain function. Diverse imaging contrasts enable direct observation of neural activity with functional sensors along with the induced hemodynamic responses. To date, decoupling the complex interplay of neurovascular coupling and dynamical physiological states has remained challenging when employing single‐modality functional neuroimaging readings. A hybrid fluorescence optoacoustic tomography platform combined with a custom data processing pipeline based on statistical parametric mapping is devised, attaining the first noninvasive observation of simultaneous calcium and hemodynamic activation patterns using optical contrasts. Correlated changes in the oxy‐ and deoxygenated hemoglobin, total hemoglobin, oxygen saturation, and rapid GCaMP6f fluorescence signals are observed in response to peripheral sensory stimulation. While the concurrent epifluorescence serves to corroborate and complement the functional optoacoustic observations, the latter further aids in decoupling the rapid calcium responses from the slowly varying background in the fluorescence recordings mediated by hemodynamic changes. The hybrid imaging platform expands the capabilities of conventional neuroimaging methods to provide more comprehensive functional readings for studying neurovascular and neurometabolic coupling mechanisms and related diseases.

23 December 2019 in Laser & Photonics Reviews
Verified
Journal Article
Open access
PDF file
ZCZhenyue Chen
Zhenyue Chen
BLBenedict Mc Larney
Benedict Mc Larney
JRJohannes Rebling
Johannes Rebling
XDXosé Luis Deán‐Ben
Xosé Luis Deán‐Ben
QZQuanyu Zhou
Quanyu Zhou
DRDaniel Razansky
Daniel Razansky
Scanning optical microscopy techniques are commonly restricted to a sub‐millimeter field‐of‐view (FOV) or otherwise employ slow mechanical translation, limiting their applicability for imaging fast biological dynamics occurring over large areas. A rapid scanning large‐field multifocal illumination (LMI) fluorescence microscopy technique is devised based on a beam‐splitting grating and an acousto‐optic deflector synchronized with a high‐speed camera to attain real‐time fluorescence microscopy over a centimeter‐scale FOV. Owing to its large depth of focus, the approach allows noninvasive visualization of perfusion across the entire mouse cerebral cortex, not achievable with conventional wide‐field fluorescence microscopy methods. The new concept can readily be incorporated into conventional wide‐field microscopes to mitigate image blur due to tissue scattering and attain optimal trade‐off between spatial resolution and FOV. It further establishes a bridge between conventional wide‐field macroscopy and laser scanning confocal microscopy, thus it is anticipated to find broad applicability in functional neuroimaging, in vivo cell tracking, and other applications looking at large‐scale fluorescent‐based biodynamics.

24 November 2022 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
ZCZhenyue Chen
Zhenyue Chen
IGIrmak Gezginer
Irmak Gezginer
MAMark-Aurel Augath
Mark-Aurel Augath
WRWuwei Ren
Wuwei Ren
YLYu-Hang Liu
Yu-Hang Liu
DRDaniel Razansky
Daniel Razansky
Multi-modal imaging is essential for advancing our understanding of brain function and unraveling pathophysiological processes underlying neurological and psychiatric disorders. Magnetic resonance (MR) and optoacoustic (OA) imaging have been shown to provide highly complementary contrasts and capabilities for preclinical neuroimaging. True integration between these modalities can thus offer unprecedented capabilities for studying the rodent brain in action. We report on a hybrid magnetic resonance and optoacoustic tomography (MROT) system for concurrent noninvasive structural and functional imaging of the mouse brain. Volumetric OA tomography was designed as an insert into a high-field MR scanner by integrating a customized MR-compatible spherical transducer array, an illumination module, and a dedicated radiofrequency coil. A tailored data processing pipeline has been developed to mitigate signal crosstalk and accurately register image volumes acquired with T1-weighted, angiography, and blood oxygenation level-dependent (BOLD) sequences onto the corresponding vascular and oxygenation data recorded with the OA modality. We demonstrate the concurrent acquisition of dual-mode anatomical and angiographic brain images with the scanner, as well as real-time functional readings of multiple hemodynamic parameters from animals subjected to oxygenation stress. Our approach combines the functional and molecular imaging advantages of OA with the superb soft-tissue contrast of MR, further providing an excellent platform for cross-validation of functional readings by the two modalities.

11 August 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
RNRuiqing Ni
Ruiqing Ni
ZCZhenyue Chen
Zhenyue Chen
JGJuan A. Gerez
Juan A. Gerez
GSGloria Shi
Gloria Shi
QZQuanyu Zhou
Quanyu Zhou
JKJan Klohs
Jan Klohs
Current intravital microscopy techniques visualize tauopathy with high-resolution, but have a small field-of-view and depth-of-focus. Herein, we report a transcranial detection of tauopathy over the entire cortex of P301L tauopathy mice using large-field multifocal illumination (LMI) fluorescence microscopy technique and luminescent conjugated oligothiophenes. In vitro assays revealed that fluorescent ligand h-FTAA is optimal for in vivo tau imaging, which was confirmed by observing elevated probe retention in the cortex of P301L mice compared to non-transgenic littermates. Immunohistochemical staining further verified the specificity of h-FTAA to detect tauopathy in P301L mice. The new imaging platform can be leveraged in pre-clinical mechanistic studies of tau spreading and clearance as well as longitudinal monitoring of tau targeting therapeutics.