22 December 2017 in Science
Determining damping of our plates: For plate tectonics to operate, a weaker layer called the asthenosphere must underlie the rigid lithospheric plates. Quantifying the difference in strength comes down to how much each layer attenuates energy. Takeuchi et al. exploited an ocean-bottom seismic network and seismic energy from the 2011 Japanese Tohoku-oki earthquake to quantify the attenuation in each layer (see the Perspective by Dalton). The attenuation of energy in the asthenosphere lined up with previous estimates, but the lithospheric attenuation was roughly one-fifth as strong as that predicted by some previous models. Science , this issue p. 1593 ; see also p. 1536
27 September 2018 in Geochemistry, Geophysics, Geosystems
We conducted broadband dispersion survey by deploying two arrays of broadband ocean bottom seismometers in the northwestern Pacific Ocean at seafloor ages of 130 and 140 Ma. By combining ambient noise and teleseismic surface wave analyses, dispersion curves of Rayleigh waves were obtained at a period range of 5–100 s and then used to invert for one‐dimensional isotropic and azimuthally anisotropic βV (VSV) profiles beneath each array. The obtained profiles show ~2% difference in isotropic βV in the low‐velocity zone (LVZ) at a depth range of 80–150 km in spite of the small difference in seafloor ages and the horizontal distance of ~1,000 km. Forward dispersion‐curve calculation for thermal models indicates that simple cooling models cannot explain the observed difference and an additional mechanism, such as sublithospheric small‐scale convection, is required. In addition, the fastest azimuths of azimuthal anisotropy in the LVZ significantly deviate from the current plate motion direction. We infer that these observations are consistent with the presence of small‐scale convection beneath the study area. As for azimuthal anisotropy in the Lid, the peak‐to‐peak intensity is 3–4% at the depth from Moho to ~40 km. The fastest direction is almost perpendicular to magnetic lineation in area A at 130 Ma and oblique to magnetic lineations in area B at 140 Ma, suggesting complex mantle flow beneath the infant Pacific Plate surrounded by three ridge axes. The intensity of azimuthal anisotropy in the LVZ is ~2%, indicating that radial anisotropy is stronger than azimuthal anisotropy therein.
24 May 2021 in Communications Earth & Environment
The Ontong Java Plateau in the western Pacific Ocean is the world’s largest oceanic plateau. It was formed 122 million years ago by a massive volcanic event that significantly affected Earth’s environment. The cause of the magmatic event remains controversial because the upper mantle structure beneath the plateau is poorly known. Here we use passive seismic data obtained through seafloor observations, alongside existing seismic data, to determine the three-dimensional radially anisotropic shear wave velocity to depths of up to 300 km. We find that the lithosphere–asthenosphere boundary is approximately 40 km deeper beneath the centre of the Ontong Java Plateau than beneath the surrounding seafloor. Based on our results and petrological and rheological constraints, we propose that the lithosphere–asthenosphere boundary has deepened as a result of underplating of dehydrated residual material beneath the pre-existing lithosphere during formation of the Ontong Java Plateau by a thermochemical mantle plume.
6 April 2018 in Science Advances
Tsunami earthquakes are a group of enigmatic earthquakes generating disproportionally large tsunamis relative to seismic magnitude. These events occur most typically near deep-sea trenches. Tsunami earthquakes occurring approximately every 10 years near Torishima on the Izu-Bonin arc are another example. Seismic and tsunami waves from the 2015 event [Mw (moment magnitude) = 5.7] were recorded by an offshore seafloor array of 10 pressure gauges, ~100 km away from the epicenter. We made an array analysis of dispersive tsunamis to locate the tsunami source within the submarine Smith Caldera. The tsunami simulation from a large caldera-floor uplift of ~1.5 m with a small peripheral depression yielded waveforms remarkably similar to the observations. The estimated central uplift, 1.5 m, is ~20 times larger than that inferred from the seismologically determined non–double-couple source. Thus, the tsunami observation is not compatible with the published seismic source model taken at face value. However, given the indeterminacy of Mzx, Mzy, and M{tensile} of a shallow moment tensor source, it may be possible to find a source mechanism with efficient tsunami but inefficient seismic radiation that can satisfactorily explain both the tsunami and seismic observations, but this question remains unresolved.
8 January 2014 in Scientific Reports
Secondary magnetic fields are induced by the flow of electrically conducting seawater through the Earth's primary magnetic field (‘ocean dynamo effect’) and hence it has long been speculated that tsunami flows should produce measurable magnetic field perturbations, although the signal-to-noise ratio would be small because of the influence of the solar magnetic fields. Here, we report on the detection of deep-seafloor electromagnetic perturbations of 10-micron-order induced by a tsunami, which propagated through a seafloor electromagnetometer array network. The observed data extracted tsunami characteristics, including the direction and velocity of propagation as well as sea-level change, first to verify the induction theory. Presently, offshore observation systems for the early forecasting of tsunami are based on the sea-level measurement by seafloor pressure gauges. In terms of tsunami forecasting accuracy, the integration of vectored electromagnetic measurements into existing scalar observation systems would represent a substantial improvement in the performance of tsunami early-warning systems.
14 June 2019 in Geophysical Research Letters
Slow earthquake size distributions have been found to follow either a power law or an exponential law, depending on the data set. We investigated the size distribution of shallow tectonic tremor events along the Nankai trough, southwestern Japan, observed in 2009, 2015, 2016, and 2018 and estimated the seismic energy radiated during the events as a measure of event size. The obtained size distributions mostly followed a power law with a b value of about 1, but an exponential law also fits well the data of the largest events; this result indicates that the size distribution follows the Gutenberg‐Richter law with an exponential taper. If only the largest events were observed, an exponential size distribution would be obtained. This exponential taper could be attributed to a source fault limitation. Because the maximum event size differed among activity periods, the source fault size varied among them, although the source areas largely overlap.