Ying Xiong

Ying Xiong

Auto-generated profile, based on publicly available information

Ying Xiong

Beijing Tongren Hospital, Beijing Tongren Eye Center, Capital Medical University, Beijing, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2023 in Asia-Pacific Journal of Ophthalmology
Verified
Journal Article
Open access
HHHai-Long He
Hai-Long He
YLYi-Xin Mbbs Liu
Yi-Xin Mbbs Liu
XCXuan-Yu Mbbs Chen
Xuan-Yu Mbbs Chen
SLSai-Guang Ling
Sai-Guang Ling
YQYue Qi
Yue Qi
ZJZi-Bing Jin
Zi-Bing Jin
Purpose: The study aimed to quantitatively evaluate the fundus tessellated density (FTD) in different categories of pathologic myopia (PM) using fundus photographs with the application of artificial intelligence. Methods: A retrospective review of 407 PM (META-PM, Category 2–Category 4) eyes was conducted, employing a biomimetic mechanism of human vision and integrated image processing technologies for FTD extraction and calculation. Different regions of interest were analyzed, including circle O4.5 (optic disc centered, diameter of 4.5 mm) and circle M1.0, M3.0, M6.0 (macular centered, diameter of 1.0, 3.0, and 6.0 mm), using 2 partitioning methods (“X” and “+”). The density of patchy (Category 3) or macular atrophy (Category 4) areas was quantified. Univariate and multivariate linear regression analyses were performed to assess the association with FTD. Results: The mean FTD of total PM eyes was 0.283, ranging from 0.002 to 0.500, and demonstrating a negative correlation with the PM category. In multivariate analysis, age was found to be significantly associated with FTD (P<0.05), while axial length did not show a significant association. Fundus tessellation of circle O4.5 and circle M6.0 displayed associations with the FTD across different PM categories. The “X” partitioning method better fit the circle M6.0 region, while both methods were suitable for the circle O4.5 region. After excluding the patchy and macular atrophic areas, the mean FTD values were 0.346 in Category 2, 0.261 in Category 3, and 0.186 in Category 4. Conclusions: The study revealed a decreasing trend in FTD values across different categories of PM, regardless of the presence or absence of patchy or macular atrophic areas. Quantifying FTD in PM could be a valuable tool for improving the existing PM classification system and gaining insights into the origin of posterior staphyloma and visual field defects in high myopia.

14 March 2019 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
SJShanshan Jin
Shanshan Jin
DFDavid S. Friedman
David S. Friedman
KCKai Cao
Kai Cao
MYMayinuer Yusufu
Mayinuer Yusufu
JZJingshang Zhang
Jingshang Zhang
XWXiu-Hua Wan
Xiu-Hua Wan
To compare the clinical performance of bifocal and trifocal intraocular lenses (IOLs) in cataract surgery, a meta-analysis on randomized controlled trials was conducted. A comprehensive literature retrieval of PubMed, Science Direct and EMBASE was performed in this systematic review. Clinical outcomes included visual acuity (VA), contrast sensitivity (CS), spectacle independence, postoperative refraction and surgical satisfaction. There were 8 RCTs included in this study. The difference of uncorrected near VA (UNVA) between the bifocal IOLs and trifocal IOLs had no significance [MD = 0.02, 95%CI: (− 0.03,0.06)]. There was no significant difference in the distant-corrected near VA (DCNVA) with MD of 0.04 [95%CI (− 0.02, 0.10)]. Compared with trifocal group, the uncorrected intermediate visual acuity (UIVA) [MD = 0.09,95%CI:(0.01,0.17)] was significantly worse in the bifocal group. No difference was found in distance-corrected intermediate VA (DCIVA) [MD = 0.09, 95%CI: (− 0.04, 0.23)] between two groups. Analysis on AT LISA subgroup indicated the bifocal group had worse intermediate VA than trifocal group (AT LISA tri 839 M) [MD = 0.18, 95%CI: (0.12, 0.24) for UIVA and MD = 0.19, 95%CI: (0.13, 0.25) for DCIVA]. However, there was no statistically significant difference between the two groups in the uncorrected distance VA (UDVA) and corrected distance visual acuity (CDVA) [MD = 0.01, 95%CI: (− 0.01,0.04) for UDVA; MD = 0.00, 95%CI: (− 0.01,0.01) for CDVA]. The postoperative refraction of bifocal group was similar to that of trifocal group [MD = -0.08, 95% CI: (− 0.19, 0.03) for spherical equivalent; MD = -0.09, 95%CI: (− 0.21, 0.03) for cylinder; MD = -0.09, 95% CI: (− 0.27, 0.08) for sphere]. No difference was found for spectacle independence, posterior capsular opacification (PCO) incidence and patient satisfaction between bifocal IOLs and trifocal IOLs. [RR = 0.89, 95% CI: (0.71, 1.12) for spectacle independence; RR = 1.81, 95% CI: (0.50, 6.54) for PCO incidence; RR = 0.98, 5% CI: (0.86, 1.12) for patient satisfaction]. Patients receiving trifocal IOLs, especially AT LISA tri 839 M, have a better intermediate VA than those receiving bifocal IOLs. Near and distance visual performance, spectacle independence, postoperative refraction and surgical satisfaction of bifocal IOLs were similar to those of trifocal IOLs.

4 July 2017 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
JWJin Da Wang
Jin Da Wang
JZJing Shang Zhang
Jing Shang Zhang
YXYing Xiong
Ying Xiong
JLJing Li
Jing Li
XLXiao Xia Li
Xiao Xia Li
XWXiu-Hua Wan
Xiu-Hua Wan
This study evaluates patients with congenital aniridia and cataract who underwent phacoemulsification, capsular tension ring placement, and foldable intraocular lens implantation. In this prospective case series, 10 patients (17 eyes) underwent cataract surgery via a 3.2 mm clear corneal incision. A continuous circular capsulorhexis with <6 mm diameter was employed. A capsular tension ring and HOYA yellow foldable posterior chamber intraocular lens was implanted. All patients wore color contact lenses postoperatively. Paired t test was used to compare visual acuity, intraocular pressure, and corneal endothelial changes before and after surgery. A single surgeon performed all surgeries. The best-corrected visual acuity improved from value 1.03 ± 0.27LogMAR preoperatively to value 0.78 ± 0.26LogMAR postoperatively (p = 0.000). The photophobic symptoms improved significantly after surgery. The mean corneal endothelial cell density before and after surgery was 3280 ± 473 cells/mm2 and 2669 ± 850 cells/mm2, respectively (p = 0.006). None of the patients developed corneal endothelial decompensation or secondary glaucoma after surgery. Treatment of congenital aniridia and coexistent cataract by phacoemulsification, posterior chamber foldable lens implantation, capsular tension ring placement was safe and effective. Use of colored contact lenses in the postoperative period can reduce photophobic symptoms in this group of patients. ChiCTR-OOC-17011638 (retrospectively registered at 12,June,2017)

18 May 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
YXYing Xiong
Ying Xiong
JLJing Li
Jing Li
NWNingli Wang
Ningli Wang
XLXue Liu
Xue Liu
ZWZhao Wang
Zhao Wang
XWXiu-Hua Wan
Xiu-Hua Wan
To determine corneal Q value and its related factors in Chinese subjects older than 30 years. Cross sectional study. 1,683 participants (1,683 eyes) from the Handan Eye Study were involved, including 955 female and 728 male with average age of 53.64 years old (range from 30 to 107 years). The corneal Q values of anterior and posterior surfaces were measured at 3.0, 5.0 and 7.0mm aperture diameters using Bausch & Lomb Orbscan IIz (software version 3.12). Age, gender and refractive power were recorded. The average Q values of the anterior surface at 3.0, 5.0 and 7.0mm aperture diameters were -0.28±0.18, -0.28±0.18, and -0.29±0.18, respectively. The average Q value of the anterior surface at the 5.0mm aperture diameter was negatively correlated with age (B = -0.003, p<0.01) and the refractive power (B = -0.013, p = 0.016). The average Q values of the posterior surface at 3.0, 5.0, and 7.0mm were -0.26±0.216, -0.26±0.214, and -0.26±0.215, respectively. The average Q value of the posterior surface at the 5.0mm aperture diameter was positively correlated with age (B = 0.002, p = 0.036) and the refractive power (B = 0.016, p = 0.043). The corneal Q value of the elderly Chinese subjects is different from that of previously reported European and American subjects, and the Q value appears to be correlated with age and refractive power.

16 October 2021 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
YXYing Xiong
Ying Xiong
YMYingyan Mao
Yingyan Mao
JLJing Li
Jing Li
XWXiuhua Wan
Xiuhua Wan
MLMeng Li
Meng Li
XSXiuli Sun
Xiuli Sun
Background: Achieving an appropriate vault is the main concern after the implantation of Implantable Collamer Lens (ICLs) for surgical correction of high myopia. The vault will vary with time and optical parameters, such as accommodation and pupil size. This research is to evaluate the vault change in Myopic and Toric ICLs under different lighting conditions; and to analyze the relationship between vault changes and pupillary responses to light. Methods: We enrolled and analyzed 68 eyes from 68 patients who were implanted with Myopic EVO ICLs; we also included 60 eyes from 60 patients who were implanted with Toric EVO ICLs. The anterior chamber depth, pupil size and the post-operative vault were evaluated, 1 week after the operation, using a Visante Optical Coherence Tomography (OCT) under different lighting conditions. For each eye that was assessed, we calculated the vault change, which is defined as the difference between vault under mesopic condition and photopic condition; and the rate of vault change, which is defined as the vault change divided by mesopic vault. Results: No significant difference was noted with the anterior chamber depth between mesopic and photopic conditions in either group. A significant decrease in vault and pupil size was detected under photopic condition in both groups. We found no difference in vault change between Myopic and Toric EVO ICLs under different lighting conditions. Moreover, the rate of vault change had a significant decrease with increased mesopic vault (baseline value). Conclusions: Too low a mesopic vault has a big rate of vault change, which may cause the contact of ICL with crystalline lens in photopic state; Too high a mesopic vault would constrict the posterior movement of pupil. The findings of the study suggest that, for patients with high or low vault, we should be more careful and must perform checks in different lighting conditions.

24 March 2022 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
XYXiong Ying
Xiong Ying
YLYu Li
Yu Li
FZFengju Zhang
Fengju Zhang