Ahmad Sakaamini

Ahmad Sakaamini

Auto-generated profile, based on publicly available information

Ahmad Sakaamini

Radiation Oncology, University of Pennsylvania, 3620 Hamilton Walk, John Morgan Building, Philadelphia, Pennsylvania, 19104-6243, UNITED STATES

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MPManish Patel
Manish Patel
ASAhmad Sakaamini
Ahmad Sakaamini
MHMatthew Harvey
Matthew Harvey
AMAndrew James Murray
Andrew James Murray
A modular, customizable, and low-cost experimental control system for electron spectrometers is described. LabVIEW is used to interface with a suite of Arduino-controlled power supplies, detectors, and stepper motors enabling a variety of different types of measurements to be performed. The structure of the LabVIEW control system and the general design of the Arduino-controlled modules are described. Examples of results from electron scattering and electron impact ionization experiments performed using this control system are presented.

16 May 2019 in The Journal of Chemical Physics
Verified
Journal Article
Open access
PDF file
EAEsam Ali
Esam Ali
CGCarlos Granados
Carlos Granados
ASAhmad Sakaamini
Ahmad Sakaamini
MHMatthew Harvey
Matthew Harvey
LALorenzo Ugo Ancarani
Lorenzo Ugo Ancarani
DMDon Madison
Don Madison
We report an experimental and theoretical investigation of electron-impact single ionization of the highest occupied molecular orbital 1t2 and the next highest occupied molecular orbital 2a1 states of CH4 at an incident electron energy of 250 eV. Triple differential cross sections measured in two different laboratories were compared with results calculated within the molecular 3-body distorted wave and generalized Sturmian function theoretical models. For ionization of the 1t2 state, the binary peak was observed to have a single maximum near the momentum transfer direction that evolved into a double peak for increasing projectile scattering angles, as has been seen for ionization of atomic p-states. A detailed investigation of this evolution was performed. As expected because of its s-type character, for ionization of the 2a1 state, only a single binary peak was observed. Overall, good agreement was found between experiment and theory.

19 November 2019 in The Journal of Chemical Physics
Verified
Journal Article
Closed access
PDF file
MHMatthew Harvey
Matthew Harvey
ASAhmad Sakaamini
Ahmad Sakaamini
MPManish Patel
Manish Patel
SASadek Amami
Sadek Amami
DMDon Madison
Don Madison
AMAndrew James Murray
Andrew James Murray
A new study of electron-impact single ionization of the HOMO 1t2 state of CH4 has been conducted at incident electron energies 20 eV and 40 eV above the ionization energy of the state. Triple differential cross sections were measured from a coplanar symmetric geometry, where scattered and ionized electrons were detected at equal angles, through to the perpendicular geometry where the outgoing electrons emerged orthogonal to the incident electron beam. At the lower energy, the electrons were detected with equal energies of 10 eV, whereas at the higher energy, data were obtained for equal energies of 20 eV and for unequal energies of 5 eV and 35 eV. The results are compared to a molecular 3-body distorted wave approximation that used a full averaging procedure to allow for the random orientation of the target, an orientation averaged molecular orbital model that averages the target wavefunction over all orientations prior to the collision, and a distorted wave Born approximation that does not include postcollisional interactions.

23 March 2022 in Physical Review A
Verified
Journal Article
Closed access
PDF file
MPManish Patel
Manish Patel
MHMatthew Harvey
Matthew Harvey
ASAhmad Sakaamini
Ahmad Sakaamini
AMAndrew James Murray
Andrew James Murray
New (e,2e) differential cross-section measurements from xenon are presented as the scattering geometry changes from coplanar to the perpendicular plane. Measurements were taken at energies of 60 eV, 80 eV, and 100 eV above the ionization potential. These new data are compared to measurements collected for the first four noble gases and to that from xenon at lower energies. The ratio of relative cross sections between xenon and helium have been measured using a xenon-helium mixture. With this data absolute differential cross sections of xenon can be determined once the helium cross sections have been calculated.

2 September 2021 in Atoms
Verified
Journal Article
Open access
PDF file
ASAhmad Sakaamini
Ahmad Sakaamini
JFJean-Baptiste Faure
Jean-Baptiste Faure
MKMurtadha A Khakoo
Murtadha A Khakoo
OZOleg Zatsarinny
Oleg Zatsarinny
Klaus R BartschatKlaus R Bartschat
Klaus R Bartschat
Benchmark intensity ratio measurements of the energy loss lines of krypton for excitation of the 4p61S0→4p55s[3/2]2, 4p55s[3/2]1, 4p55s′[1/2]0, and 4p55s′[1/2]1 transitions are reported, these being the lowest electronic excitations for krypton. The importance of these ratios as stringent tests of theoretical electron scattering models for the noble gases is discussed, as well as the role of spin-exchange and direct processes regarding the angular dependence of these ratios. The experimental data are compared with predictions from fully-relativistic B-spline R-matrix (close-coupling) calculations.

14 July 2023 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
ASAhmad Sakaamini
Ahmad Sakaamini
ASAlexander Van Slyke
Alexander Van Slyke
JPJulien Partouche
Julien Partouche
TWTianming Wu
Tianming Wu
RWRodney D Wiersma
Rodney D Wiersma
Objective. Quality assurance (QA) testing must be performed at regular intervals to ensure that medical devices are operating within designed specifications. Numerous QA phantoms and software packages have been developed to facilitate measurements of machine performance. However, due to the hard-coded nature of geometric phantom definition in analysis software, users are typically limited to the use of a small subset of compatible QA phantoms. In this work, we present a novel AI-based universal Phantom (UniPhan) algorithm that is not phantom specific and can be easily adapted to any pre-existing image-based QA phantom. Approach. Extensible Markup Language Scalable Vector Graphics (XML-SVG) was modified to include several new tags describing the function of embedded phantom objects for use in QA analysis. Functional tags include contrast and density plugs, spatial linearity markers, resolution bars and edges, uniformity regions, and light-radiation field coincidence areas. Machine learning was used to develop an image classification model for automatic phantom type detection. After AI phantom identification, UniPhan imported the corresponding XML-SVG wireframe, registered it to the image taken during the QA process, performed analysis on the functional tags, and exported results for comparison to expected device specifications. Analysis results were compared to those generated by manual image analysis. Main results. XML-SVG wireframes were generated for several commercial phantoms including ones specific to CT, CBCT, kV planar imaging, and MV imaging. Several functional objects were developed and assigned to the graphical elements of the phantoms. The AI classification model was tested for training and validation accuracy and loss, along with phantom type prediction accuracy and speed. The results reported training and validation accuracies of 99%, phantom type prediction confidence scores of around 100%, and prediction speeds of around 0.1 s. Compared to manual image analysis, Uniphan results were consistent across all metrics including contrast-to-noise ratio, modulation-transfer function, HU accuracy, and uniformity. Significance. The UniPhan method can identify phantom type and use its corresponding wireframe to perform QA analysis. As these wireframes can be generated in a variety of ways this represents an accessible automated method of analyzing image-based QA phantoms that is flexible in scope and implementation.