Micro(nano)plastics are considered an emerging threat to human health because they can interact with biological systems. In fact, these materials have already been found in the human body, such as in the lungs. However, limited data are available on the behavior of these materials under biological conditions and their impact on human cells, specifically on alveolar epithelial cells. In this study, micro(nano)plastics were exposed to various simulated biological fluids (artificial lysosomal fluids and Gamble's solution) for 2-80 h. Pristine and treated plastic particles were characterized based on their surface chemistry, zeta potentials, and elemental composition. Various toxicological endpoints (mitochondrial membrane potential, lactate dehydrogenase, protein, and antioxidant levels) were examined using A549 lung carcinoma cells. The surface characteristics of the treated micro(nano)plastics and the toxicological endpoints of A549 cells were found to be influenced by the simulated biological media, specifically with high concentrations of the treated micro(nano)plastics and increasing exposure under biological conditions. Moreover, the toxicological endpoints were strongly linked to the chemistry of plastics and included multiple processes in response to the plastics; different biological pathways were obtained in artificial lysosomal fluid and Gamble's solution.
Surface-enhanced Raman scattering (SERS) is an emerging spectroscopy technique for detecting and characterizing chemical or biological structures in the vicinity of plasmonic nanostructures. Colloidal, solid, and flexible nanostructures are widely used in SERS experiments to enhance the Raman intensity. The nanostructure used in SERS is one of the main influencing parameters and a growing research area. Fabrication of simple and cheap SERS substrates with a high enhancement factor is desired. In this study, we fabricated a reproducible, cheap, and flexible SERS active strip by coating natural diatomite (biosilica) with silver nanoparticles (AgNPs) using the layer-by-layer assembly method and the fabricated strip is used for the label-free identification of circulating cancer protein biomarkers. SERS active strips were fabricated having different numbers of AgNP layers on natural diatomite and comprehensive characterization techniques such as X-ray diffraction (XRD), scanning electron microscopy (SEM), and UV/vis absorption spectrophotometry were used. SERS activities of the strips depending on the number of layers were evaluated using 4-aminothiophenol (4-ATP) and rhodamine 6G (Rh6G) molecules. We found that the SERS intensity is strongly dependent on the number of AgNP layers, with the maximum SERS intensity obtained from the strip with 5 layers of AgNPs, having a 2.0 × 105 enhancement factor. The strip with the highest SERS activity was used for the label-free identification of circulating cancer protein biomarkers (HER2, CA15-3, PSA, MUC4, and CA27-29). The results demonstrate that the fabricated strip can help in the effective label-free identification of circulating protein biomarkers and open new directions for SERS-based label-free biosensing applications.
Rapid and reliable microbial contamination detection is essential for hygiene monitoring in food production, healthcare, and environmental settings. Although ATP-based bioluminescence assays are widely used for rapid cleanliness assessment, conventional luminometer-based systems are limited by high cost, large sample volume requirements, limited dynamic range, and lack of bacterial specificity. In this work, we present an improved CMOS-based bioluminescent biosensing platform for quantitative ATP detection and species-selective detection of Escherichia coli. The platform integrates SuperSnap ATP chemistry and MicroSnap E. coli enzyme-specific assays with a CMOS image sensor housed in a light-tight optical enclosure, enabling chemiluminescence detection using sample volumes as low as 10 μL. Quantitative ATP measurements in SuperSnap buffer exhibited strong linearity and good agreement with a commercial luminometer, achieving a limit of detection of 3.51 nM ATP. When normalized to absolute ATP amount, the CMOS platform demonstrated sensitivity comparable to that of the luminometer despite operating with a 30-fold smaller sample volume. In contrast to the luminometer, which saturated at approximately 75 nM ATP, the CMOS platform maintained linear response up to 200 nM ATP, demonstrating a substantially broader dynamic range without requiring sample dilution. Selective E. coli detection achieved a limit of detection of approximately 412 CFU mL-1 following 6-h enrichment and 10 min detection, while maintaining selective response in mixed bacterial samples containing Staphylococcus epidermidis. Performance was further validated through representative surface sampling and controlled surface contamination experiments. Overall, the CMOS-based platform provides a low-cost and portable alternative to conventional luminometers for both rapid hygiene monitoring and targeted microbial detection at the point-of-need.
Detection of microbial contamination is essential for hygiene monitoring in food production, healthcare, and environmental settings. While ATP-based bioluminescence assays are widely used for assessing cleanliness, commercial luminometers are costly, require large sample volumes, are non-specific for bacteria, and exhibit low dynamic range that limit their use. We report here a compact biosensing platform for sensitive ATP quantification and species-selective detection of Escherichia coli by integrating SuperSnap ATP chemistry and MicroSnap E. coli enzyme-specific assays. We use a backside-illuminated CMOS image sensor operated in contact-mode, allowing efficient detection of chemiluminescence from sample volumes as low as 10 µL. ATP measurements in SuperSnap buffer exhibit strong linearity and good agreement with commercial luminometers both at low and high concentration ranges, with limits of detection down to 3.51 nM ATP. When normalized to total ATP amount, the CMOS-based platform achieves sensitivity close to the luminometer, despite 30-fold smaller sample volume. Importantly, while the luminometer response saturates at ~75 nM ATP, the CMOS-based system maintains quantification up to 200 nM, demonstrating significantly larger dynamic range, which is a key practical advantage for real-world hygiene monitoring. Species-selective detection of E. coli was demonstrated using MicroSnap chemistry, achieving a detection limit of approximately 412 CFU mL⁻¹ following a 6-hour enrichment and a 10-minute detection step. Selectivity was preserved in mixed bacterial samples containing Staphylococcus epidermidis, confirming enzyme-mediated specificity. These results establish CMOS-based bioluminescent biosensing as a low-cost, portable, and versatile tool for rapid hygiene monitoring and targeted microbial detection at the point-of-need.