Russell L. Woods

Russell L. Woods

Auto-generated profile, based on publicly available information

Russell L. Woods

Schepens Eye Research Institute, Massachusetts Eye and Ear, Boston, MA, USA

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2011 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
FDFrançois Delori
François Delori
JGJonathan P. Greenberg
Jonathan P. Greenberg
RWRussell L. Woods
Russell L. Woods
JFJörg Fischer
Jörg Fischer
TDTobias Duncker
Tobias Duncker
RSR Theodore Smith
R Theodore Smith
Purpose.: To evaluate the feasibility and reliability of a standardized approach for quantitative measurements of fundus autofluorescence (AF) in images obtained with a confocal scanning laser ophthalmoscope (cSLO). Methods.: AF images (30°) were acquired in 34 normal subjects (age range, 20–55 years) with two different cSLOs (488-nm excitation) equipped with an internal fluorescent reference to account for variable laser power and detector sensitivity. The gray levels (GLs) of each image were calibrated to the reference, the zero GL, and the magnification, to give quantified autofluorescence (qAF). Images from subjects and fixed patterns were used to test detector linearity with respect to fluorescence intensity, the stability of qAF with change in detector gain, field uniformity, effect of refractive error, and repeatability. Results.: qAF was independent of detector gain and laser power over clinically relevant ranges, provided that detector gain was adjusted to maintain exposures within the linear detection range (GL < 175). Field uniformity was better than 5% in a central 20°-diameter circle but decreased more peripherally. The theoretical inverse square magnification correction was experimentally verified. Photoreceptor bleaching for at least 20 seconds was performed. Repeatability (95% confidence interval) for same day and different-day retests of qAF was ±6% to ±14%. Agreement (95% confidence interval) between the two instruments was <11%. Conclusions.: Quantitative AF imaging appears feasible. It may enhance understanding of retinal degeneration, serve as a diagnostic aid and as a sensitive marker of disease progression, and provide a tool to monitor the effects of therapeutic interventions.

1 May 2014 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
TBTomas R. Burke
Tomas R. Burke
TDTobias Duncker
Tobias Duncker
RWRussell L. Woods
Russell L. Woods
JGJonathan P. Greenberg
Jonathan P. Greenberg
JZJana Zernant
Jana Zernant
FDFrançois C. Delori
François C. Delori
Purpose.: To quantify fundus autofluorescence (qAF) in patients with recessive Stargardt disease (STGD1). Methods.: A total of 42 STGD1 patients (ages: 7–52 years) with at least one confirmed disease-associated ABCA4 mutation were studied. Fundus AF images (488-nm excitation) were acquired with a confocal scanning laser ophthalmoscope equipped with an internal fluorescent reference to account for variable laser power and detector sensitivity. The gray levels (GLs) of each image were calibrated to the reference, zero GL, magnification, and normative optical media density to yield qAF. Texture factor (TF) was calculated to characterize inhomogeneities in the AF image and patients were assigned to the phenotypes of Fishman I through III. Results.: Quantified fundus autofluorescence in 36 of 42 patients and TF in 27 of 42 patients were above normal limits for age. Young patients exhibited the relatively highest qAF, with levels up to 8-fold higher than healthy eyes. Quantified fundus autofluorescence and TF were higher in Fishman II and III than Fishman I, who had higher qAF and TF than healthy eyes. Patients carrying the G1916E mutation had lower qAF and TF than most other patients, even in the presence of a second allele associated with severe disease. Conclusions.: Quantified fundus autofluorescence is an indirect approach to measuring RPE lipofuscin in vivo. We report that ABCA4 mutations cause significantly elevated qAF, consistent with previous reports indicating that increased RPE lipofuscin is a hallmark of STGD1. Even when qualitative differences in fundus AF images are not evident, qAF can elucidate phenotypic variation. Quantified fundus autofluorescence will serve to establish genotype-phenotype correlations and as an outcome measure in clinical trials.

1 August 2013 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
JGJonathan P. Greenberg
Jonathan P. Greenberg
TDTobias Duncker
Tobias Duncker
RWRussell L. Woods
Russell L. Woods
RSR Theodore Smith
R Theodore Smith
JSJanet R. Sparrow
Janet R. Sparrow
FDFrançois C. Delori
François C. Delori
Purpose.: Fundus autofluorescence was quantified (qAF) in subjects with healthy retinae using a standardized approach. The objective was to establish normative data and identify factors that influence the accumulation of RPE lipofuscin and/or modulate the observed AF signal in fundus images. Methods.: AF images were acquired from 277 healthy subjects (age range: 5–60 years) by employing a Spectralis confocal scanning laser ophthalmoscope (cSLO; 488-nm excitation; 30°) equipped with an internal fluorescent reference. For each image, mean gray level was calculated as the average of eight preset regions, and was calibrated to the reference, zero-laser light, magnification, and optical media density from normative data on lens transmission spectra. Relationships between qAF and age, sex, race/ethnicity, eye color, refraction/axial length, and smoking status were evaluated as was measurement repeatability and the qAF spatial distribution. Results.: qAF levels exhibited a significant increase with age. qAF increased with increasing eccentricity up to 10° to 15° from the fovea and was highest superotemporally. qAF values were significantly greater in females, and, compared with Hispanics, qAF was significantly higher in whites and lower in blacks and Asians. No associations with axial length and smoking were observed. For two operators, between-session repeatability was ±9% and ±12%. Agreement between the operators was ±13%. Conclusions.: Normative qAF data are a reference tool essential to the interpretation of qAF measurements in ocular disease.

1 July 1997 in Optometry and Vision Science
Verified
Journal Article
Closed access
DADavid A. Atchison
David A. Atchison
WCW Neil Charman
W Neil Charman
RWRussell L. Woods
Russell L. Woods

1 July 2007 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
RGRobert B. Goldstein
Robert B. Goldstein
RWRussell L. Woods
Russell L. Woods
EPEli Peli
Eli Peli

1 January 1997 in Clinical and Experimental Optometry
Verified
Journal Article
Closed access
PDF file
ABAlex Black
Alex Black
JLJan E Lovie‐Kitchin
Jan E Lovie‐Kitchin
RWRussell L Woods
Russell L Woods
NANicole Arnold
Nicole Arnold
JBJohn Byrnes
John Byrnes
JMJane Murrish
Jane Murrish