Andressa Cartaxo de Almeida

Andressa Cartaxo de Almeida

Auto-generated profile, based on publicly available information

Andressa Cartaxo de Almeida

Faculdade de Odontologia de Pernambuco

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2019 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
KRKaline Romeiro
Kaline Romeiro
AAAndressa de Almeida
Andressa de Almeida
MCMarcely Cassimiro
Marcely Cassimiro
LGLuciana Gominho
Luciana Gominho
EDEugênia Dantas
Eugênia Dantas
DADiana Albuquerque
Diana Albuquerque

2 April 2020 in International Endodontic Journal
Verified
Journal Article
Closed access
PDF file
CTCHRISTIANNE TAVARES VELOZO TELLES
CHRISTIANNE TAVARES VELOZO TELLES
SSS. Silva
S. Silva
AAA. Almeida
A. Almeida
KRK. Romeiro
K. Romeiro
BVB. Vieira
B. Vieira
DAD. S. De Albuquerque
D. S. De Albuquerque

2 June 2017 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
MCMarcely Cassimiro
Marcely Cassimiro
KRKaline Romeiro
Kaline Romeiro
LGLuciana Gominho
Luciana Gominho
AAAndressa de Almeida
Andressa de Almeida
LCLarissa Costa
Larissa Costa
DADiana Albuquerque
Diana Albuquerque
This study aims to evaluate the frequency of dentinal defects after root canal preparation with the ProTaper NEXT, K3XF and WaveOne GOLD systems using microcomputed tomography. Sixty permanent mandibular incisors with a single canal were selected. Inspection of the teeth was performed under a stereomicroscope (15x) to observe the presence of pre-existing cracks and fractures lines. Samples were divided into three experimental groups (n = 20): ProTaper NEXT (PTN), K3XF (K3XF) and WaveOne GOLD (WOG). Specimens were scanned through high-resolution microcomputed tomography before and after the preparation of the root canal. Subsequently, all the axial images were examined by two different methods to find possible dentinal defects. Furthermore, an analysis of each millimeter of ten apical millimeters was also performed. The absence or presence of dentinal defects was screened by 3 pre-calibrated blinded examiners. After analysing all 45,720 slices, dentinal defects were observed in 48,33% (22096 slices). PTN, K3XF and WOG groups represented 11,11% (5079 slices), 17,22% (7873 slices) and 20% (n = 9144) of the cross-sectional images, respectively. At 10 apical millimeters (600 slices), 33,33% (200 slices) presented some dentinal defects, representing 7,22% (43 slices), 13,33% (80 slices) and 12,77% (77 slices) of the cross-sectional images in the PTN, K3XF and WOG groups, respectively. All the dentinal defects presented in the postoperative images existed in the images prior to instrumentation. There was no correlation between the preparation of a root canal using the PTN, K3XF and WOG systems and the formation of new dentinal defects.

17 September 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AAAndressa Almeida
Andressa Almeida
KRKaline Romeiro
Kaline Romeiro
MCMarcely Cassimiro
Marcely Cassimiro
LGLuciana Gominho
Luciana Gominho
EDEugênia Dantas
Eugênia Dantas
DADiana Albuquerque
Diana Albuquerque
This study aimed to analyze the potential occurrence of dentinal defects after the removal of a root canal filling with two different sealers using Reciproc (RC) or Reciproc Blue (RB). The mesial roots of 60 mandibular molars with a Vertucci type IV configuration were selected. The samples were initially instrumented with Reciproc (R25) and then divided into the following four experimental groups according to the endodontic sealer and retreatment instrument (n = 15): BC Sealer/Reciproc (BCRC); BC Sealer/Reciproc Blue (BCRB); AH Plus/Reciproc (AHRC); and AH Plus/Reciproc Blue (AHRB). Then, the samples were scanned under micro-CT after obturation and removal of the filling material. Two analyses were conducted. First, an evaluation was performed on all the axial images, and another analysis evaluated each millimeter of the 10 mm from the apex. Dentinal defects were observed in all the samples. All of the identified defects in the images after filling material removal were present in the corresponding images after obturation. The use of AH Plus and EndoSequence BC Sealer, and filling material removal using RC and RB instruments did not induce dentinal defects.

29 July 2024 in Revista ft
Verified
Journal Article
Closed access
RTRosana Maria Coelho Travassos Travassos
Rosana Maria Coelho Travassos Travassos
OSOrientadora: Drª Médica Veterinária Samara Silva de Souza
Orientadora: Drª Médica Veterinária Samara Silva de Souza
KRKaline Romeiro
Kaline Romeiro
LGLuciana Gominho
Luciana Gominho
ACAdriane Chaves
Adriane Chaves
PFPedro Fernandes
Pedro Fernandes
Periapical lesions are found associated with the apex of a tooth without vitality, after contamination of the root canals, characterized radiographically by the presence of a radiolucent image at the apex of the affected element. The objective of this work is to report the regression of a periapical lesion, with a diagnosis of periapical abscess without fistula, after conventional endodontic treatment, confirmed through radiographic examinations and clinical images. A 24-year-old female patient complained of pain in the right anterior region and, days before the initial consultation, reported drainage of purulent secretion through the gums. In the intraoral physical examination, edema was observed at the bottom of the vestibule close to the incisors, pain on horizontal and vertical percussion and on the periapical radiograph the presence of a radiolucent image was observed close to the apex of tooth 36. A cold pulp sensitivity test was performed, obtaining a negative result. . With the purpose of decontaminating the root canals, endodontic treatment was carried out, using a preparation technique associated with the activation of chemical irrigants and intracanal medication between sessions. After a few weeks, the remission of clinical signs of inflammation and infection was observed and, after 3 months, radiographically, the beginning of repair of the lesion with bone formation was evident. The reported case highlights the importance of effective decontamination of the root canal as a determining factor for the regression process of periapical lesions. A longer period of clinical and radiographic follow-up of the case is necessary to verify complete repair.

2 October 2021 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
FDFábio Luiz Cunha D'Assunção
Fábio Luiz Cunha D'Assunção
JSJuan Ramon Salazar Silva
Juan Ramon Salazar Silva
KAKaren Christine Lacerda Arnaud
Karen Christine Lacerda Arnaud
TLThiago Bezerra Leite
Thiago Bezerra Leite
JSJozemar Pereira dos Santos
Jozemar Pereira dos Santos
AAAndressa Cartaxo de Almeida
Andressa Cartaxo de Almeida
Objective: To evaluate the effect of 2% chlorhexidine (CHX) and 2.5% sodium hypochlorite (NaOCl) on the accuracy and repeatability of three Electronic Apex Locators (EALs). Methodology: Thirty one human teeth were connected to a platform, irrigated with 2.0% CHX, and obtained two readings, again irrigated with 2.5% NaOCl and obtained two more readings. The distance between the tip of the file and the apical constriction was measured. Repeatability was calculated using the intraclass correlation coefficient (ICC) and repeatability coefficient (CR). Results: For CHX 2%, with the Mini Apex Locator, 25 of 31 electronic measurements were accurate (80.6%), 28 of 31 measurements for iPex (90.3%) and for Root ZX II 26 (83, 9%). For 2.5% NaOCl, with the Mini Apex Locator, 25 of the 31 measurements were accurate (80.6%), 28 of the 31 measurements for the iPex (90.3%) and for the Root ZX II, 24 (77, 4%). There were no differences between the two irrigants (p>0.05). The values ​​(ICC) were 0.975 and 0.994 for the Mini Apex Locator, 0.981 and 0.971 for the i Pex and 0.994 and 0.995 for the Root ZX II. When using CHX, the (CR) was 0.196 for the Mini Apex Locator, 0.152 for the iPex and 0.088 for the Root ZX II. When using 2.5% NaOCl, the (CR) was 0.088 for the Mini Apex Locator, 0.196 for the iPex and 0.088 for the Root ZX II. Conclusions: The use of 2% CHX and 2.5% NaOCl did not affect the accuracy and repeatability of the three devices.