Elizabeth Russell Esposito

Elizabeth Russell Esposito

Auto-generated profile, based on publicly available information

Elizabeth Russell Esposito

Center for the Intrepid, Brooke Army Medical Center, Fort Sam Houston, TX, USA

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2011 in Footwear Science
Verified
Journal Article
Closed access
JHJoseph Hamill
Joseph Hamill
ERElizabeth M. Russell
Elizabeth M. Russell
AGAllison H. Gruber
Allison H. Gruber
RMRoss Miller
Ross Miller
Increased impact characteristics are often cited as a cause of running injuries. One method that has been used to reduce impact characteristics is to increase the thickness of the midsole of running footwear with the intention of attenuating greater shock from the foot-ground collision. A second method that has been suggested is to run barefoot. The purpose of this study was to compare the impact characteristics of running footwear of different midsole thickness to a barefoot condition. Three-dimensional kinematic and kinetic data were collected as participants ran at their preferred running speed and at a fixed speed. Impact characteristics (impact peak, time to impact peak and vertical loading rate) were derived from the vertical ground reaction force component. Ankle and knee joint stiffness during the loading phase of support were derived from the change in moment divided by the change in angle. The impact parameters were statistically analyzed using a two-way, repeated measures ANOVA. There were no significant speed by footwear condition interactions. For impact peak, ankle stiffness and knee stiffness, there was no difference among the shod conditions but there were significant differences between the shod and barefoot conditions. Based on their strike index, participants in this study appeared to alter their footfall pattern from a rearfoot to a midfoot pattern when changing from running shod to barefoot. It may be concluded that the change in the impact characteristics is a result of changing footfall pattern rather than midsole thickness.

1 September 2014 in Clinical Biomechanics
Verified
Journal Article
Closed access
NHNicole G. Harper
Nicole G. Harper
EEElizabeth Russell Esposito
Elizabeth Russell Esposito
JWJason M. Wilken
Jason M. Wilken
RNRichard R. Neptune
Richard R. Neptune

1 June 2016 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
EEElizabeth Russell Esposito
Elizabeth Russell Esposito
JWJennifer M Aldridge Whitehead
Jennifer M Aldridge Whitehead
JWJason M Wilken
Jason M Wilken
Individuals with leg amputations who use passive prostheses have greater metabolic demands than non-amputees likely due to limited net positive work compared to a biological ankle. New powered ankle–foot prostheses can perform net positive mechanical work to aid push-off capabilities, which may reduce metabolic demands. Compare step-to-step transition work and metabolic demand during level and inclined walking using passive and powered ankle-foot prostheses. Repeated measures. Six individuals with transtibial amputation and six able-bodied controls walked at a standardized speed across level ground and up a 5° incline. Calculated measures included mechanical work during step-to-step transitions from the trailing prosthetic to leading intact limb, steady state metabolic rate, and ankle joint kinetics and kinematics. The powered prosthesis generated 63% greater trailing limb step-to-step transition work than the passive during level walking only (p = 0.004). Metabolic rate was lower with the powered prosthesis during level (p = 0.006) but not inclined walking (p = 0.281). The powered prosthesis increased ankle power compared to the passive, to the extent that power was normalized to controls during inclined walking and greater than controls during level walking. The powered prosthesis improved ankle power, metabolic rate, and step-to-step transition work on level ground, with few negative consequences on inclines. These results may be used to guide the development and use of actively powered prosthetic devices in high-functioning individuals. Overall, powered devices offer biomechanical and metabolic benefits over passive energy storage and return designs on level ground and perform as well as a passive model on inclines. The lower metabolic demand when using the powered device may delay fatigue for individuals with transtibial amputation when walking over level ground.

1 October 2014 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
EEElizabeth Russell Esposito
Elizabeth Russell Esposito
RBRyan V. Blanck
Ryan V. Blanck
NHNicole G. Harper
Nicole G. Harper
JHJoseph R. Hsu
Joseph R. Hsu
JWJason M. Wilken
Jason M. Wilken
Ankle-foot orthoses (AFOs) are commonly prescribed during rehabilitation after limb salvage. AFO stiffness is selected to help mitigate gait deficiencies. A new custom dynamic AFO, the Intrepid Dynamic Exoskeletal Orthosis (IDEO), is available to injured service members but prescription guidelines are limited. In this study we ask (1) does dynamic AFO stiffness affect gait parameters such as joint angles, moments, and powers; and (2) can a given dynamic AFO stiffness normalize gait mechanics to noninjured control subjects? Thirteen patients with lower limb salvage (ankle arthrodesis, neuropathy, foot/ankle reconstruction, etc) after major lower extremity trauma and 13 control subjects who had no lower extremity trauma and wore no orthosis underwent gait analysis at a standardized speed. Patients wore their custom IDEO with posterior struts of three different stiffnesses: nominal (clinically prescribed stiffness), compliant (20% less stiff), and stiff (20% stiffer). Joint angles, moments, powers, and ground reaction forces were compared across the varying stiffnesses of the orthoses tested and between the patient and control groups. An increase in AFO compliance resulted in 20% to 26% less knee flexion relative to the nominal (p = 0.003) and stiff (p = 0.001) conditions, respectively. Ankle range of motion and power generation were, on average, 56% (p < 0.001) and 63% (p < 0.001), respectively, less than controls as a result of the relatively fixed ankle position. Patients with limb salvage readily adapted to different dynamic AFO stiffnesses and demonstrated few biomechanical differences among conditions during walking. None of the stiffness conditions normalized gait to controls. The general lack of differences across a 40% range of strut stiffness suggests that orthotists do not need to invest large amounts of time identifying optimal device stiffness for patients who use dynamic AFOs for low-impact activities such as walking. However, choosing a stiffer strut may more readily translate to higher-impact activities and offer less chance of mechanical failure.

1 September 2016 in Gait & Posture
Verified
Journal Article
Closed access
KKKenton Kaufman
Kenton Kaufman
EMEmily Miller
Emily Miller
TKTrevor Kingsbury
Trevor Kingsbury
EEElizabeth Russell Esposito
Elizabeth Russell Esposito
EWErik Wolf
Erik Wolf
MWMarilynn Wyatt
Marilynn Wyatt

1 April 2006 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Closed access
WSWilliam Sands
William Sands
JMJeni R. Mcneal
Jeni R. Mcneal
MSMichael H. Stone
Michael H. Stone
ERElizabeth M. Russell
Elizabeth M. Russell
MJMonem Jemni
Monem Jemni
The most popular method of stretching is static stretching. Vibration may provide a means of enhancing range of motion beyond that of static stretching alone. This study sought to observe the effects of vibration on static stretching to determine whether vibration-aided static stretching could enhance range of motion acquisition more than static stretching alone in the forward split position. Ten highly trained male volunteer gymnasts were randomly assigned to experimental (N = 5) and control (N = 5) groups. The test was a forward split with the rear knee flexed to prevent pelvic misalignment. Height of the anterior iliac spine of the pelvis was measured at the lowest split position. Athletes stretched forward and rearward legs to the point of discomfort for 10 s followed by 5 s of rest, repeated four times on each leg and split position (4 min total). The experimental group stretched with the device turned on; the control group stretched with the device turned off. A pretest was followed by an acute phase posttest, then a second posttest measurement was performed following 4 wk of treatment. Difference scores were analyzed. The acute phase showed dramatic increases in forward split flexibility for both legs (P < 0.05), whereas the long-term test showed a statistically significant increase in range of motion on the right rear leg split only (P < 0.05). Effect sizes indicated large effects in all cases. This study showed that vibration can be a promising means of increasing range of motion beyond that obtained with static stretching in highly trained male gymnasts.