9 April 2019 in IEEE Transactions on Industrial Electronics
This paper proposes a new reader solenoid coil with a metal tube for use in high-temperature water, mud, and other impurities in an oil well downhole. The coil can read commands transmitted from the ground surface via inactive microtags and write the sensor data collected in the downhole into the microtags for transmission to the ground. By combining transformer theory and electromagnetic field theory, the main parameters of the reader solenoid coil in the harsh industrial environment in a downhole are calculated and the main factors responsible for RFID communication failure at 125±10 kHz of the reader solenoid coil are analyzed. Then, a mathematical model is developed to describe the relationship among the electromagnetic field density, the ac resistance of complex permittivity, and the complex permeability with water and the metal tube of the reader solenoid coil. Methods to reduce the changes in the inductance and resistance are presented. The minimum flux density of the reader solenoid coil is designed to provide a continuous energy supply to inactive microtags, and the identification rate by the reader is 100% at 125±10 kHz. Furthermore, the reader solenoid coil was tested in an industrial environment in the downholes of six oil well drilling systems for two years.
2 April 2018 in IEEE Antennas and Wireless Propagation Letters
This study investigated the effective length of the reader solenoid coil used for oil-well drilling, and the time required for the communication between rapidly moving microtags and the reader solenoid coil attached to the equipment pipeline was calculated. The effective length of the solenoid coil was computed for both static and moving microtags. Then, a mathematical model was developed to describe the relationship among the effective length of the reader solenoid coil, baud rate, number of data bits, and microtag speed. Calculations were performed to design two reader solenoid coils, which were tested experimentally with a carrier frequency of 125 ± 10 kHz. The results show that the effective length of the reader solenoid coil is proportional to the microtag speed and number of data bits but inversely proportional to the baud rate. The proposed system provides a continuous energy supply to the microtags, and the moving microtag identification rate by the reader is 100%. The experimental and calculation results were in good agreement. Furthermore, reader solenoid coils of two lengths were used in the downholes of six oil-well drilling systems over two years.