Vladimír Boža

Vladimír Boža

Auto-generated profile, based on publicly available information

Vladimír Boža

Powerful Medical

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2021 in IEEE/ACM Transactions on Computational Biology and Bioinformatics
Verified
Journal Article
Open access
VBVladimír Boža
Vladimír Boža
PPPeter Perešíni
Peter Perešíni
BBBroňa Brejová
Broňa Brejová
Tomas VinarTomas Vinar
Tomas Vinar
In nanopore sequencing, electrical signal is measured as DNA molecules pass through the sequencing pores. Translating these signals into DNA bases (base calling) is a highly non-trivial task, and its quality has a large impact on the sequencing accuracy. The most successful nanopore base callers to date use convolutional neural networks (CNN) to accomplish the task. Convolutional layers in CNNs are typically composed of filters with constant window size, performing best in analysis of signals with uniform speed. However, the speed of nanopore sequencing varies greatly both within reads and between sequencing runs. Here, we present dynamic pooling, a novel neural network component, which addresses this problem by adaptively adjusting the pooling ratio. To demonstrate the usefulness of dynamic pooling, we developed two base callers: Heron and Osprey. Heron improves the accuracy beyond the experimental high-accuracy base caller Bonito developed by Oxford Nanopore. Osprey is a fast base caller that can compete in accuracy with Guppy high-accuracy mode, but does not require GPU acceleration and achieves a near real-time speed on common desktop CPUs. Availability: https://github.com/fmfi-compbio/osprey, https://github.com/fmfi-compbio/heron

1 September 2024 in medRxiv
Verified
Preprint
Open access
PDF file
ADAnthony Demolder
Anthony Demolder
Viera Maslej KrešňákováViera Maslej Krešňáková
Viera Maslej Krešňáková
MHMichal Hojcka
Michal Hojcka
VBVladimir Boza
Vladimir Boza
AIAndrej Iring
Andrej Iring
RHRobert Herman
Robert Herman
Background The digitization of electrocardiograms (ECGs) is an important process in modern healthcare, enabling the preservation, transmission, and advanced analysis of ECG data. Traditional methods for digitizing ECGs from paper formats face significant challenges, particularly in real-world scenarios with varying image quality, paper distortions, and overlapping signals. Existing solutions often require manual input and are limited by their dependence on high-quality images and standardized layouts. Methods This study introduces a fully automated, deep learning-based approach for high-precision ECG digitization, imple- menting a two-stage process. In the ECG normalization phase, image distortions are corrected, axes are calibrated, and a standardized grid structure is generated. The ECG reconstruction phase uses deep learning techniques to extract and digitize the leads, with subsequent post-processing to refine the digital signal. The tool was evaluated using a custom-built PMcardio ECG Image Database (PM-ECG-ID) comprising 6,000 ECG images generated from 100 unique ECGs, subjected to various augmentations to simulate real-world challenges. Performance was assessed using Pearson’s correlation coefficient (PCC), root mean squared error (RMSE), and signal-to-noise ratio (SNR). Results The digitization tool demonstrated an average PCC consistently exceeding 91% across all leads, SNR above 12.5 dB and an RMSE below 0.10 mV. The time to ECG digitization was consistently less than 10 seconds. The failure rate was low, averaging 6.62%, with most failures occurring under extreme conditions such as severe blurring or significant image degradation. The tool maintained robust performance even under challenging scenarios, such as low-resolution images, distorted grids, and overlapping signals. Performance metrics indicated slight variations across different leads, with leads V3-V5 showing marginally higher RMSE and lower PCC, reflecting the complexity of digitizing large amplitude signals. Conclusion Our deep learning-based approach for ECG digitization delivers high precision and reliability, effectively addressing real-world challenges such as image distortions, lighting variations, and overlapping signals. This fully automated method enhances the accessibility and utility of ECG data, supporting advanced AI-driven analysis in cardiac healthcare.

15 July 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
VBVladimír Boža
Vladimír Boža
EBEduard Batmendijn
Eduard Batmendijn
PPPeter Perešíni
Peter Perešíni
VHViktória Hodorová
Viktória Hodorová
HLHana Lichancová
Hana Lichancová
Tomas VinarTomas Vinar
Tomas Vinar
Base calling in nanopore sequencing is a difficult and computationally intensive problem, typically resulting in high error rates. In many applications of nanopore sequencing, analysis of raw signal is a viable alternative. Dynamic time warping (DTW) is an important building block for raw signal analysis. In this paper, we propose several improvements to DTW class of algorithms to better account for specifics of nanopore signal modeling. We have implemented these improvements in a new signal-to-reference alignment tool Nadavca. We demonstrate that Nadavca alignments improve unsupervised methylation detection over Tombo. We also demonstrate that by providing additional information about the discriminative power of positions in the signal, an otherwise unsupervised method can approach the accuracy of supervised models. Availability and implementation: Nadavca is available under MIT license at https://github.com/fmfi-compbio/nadavca . Nanopore sequencing data sets are available from ENA bioproject PRJEB64246. Jaminaea angkorensis reference genome assembly is available from Zenodo https://doi.org/10.5281/zenodo.8145315 .