Chunfang Jian

Chunfang Jian

Auto-generated profile, based on publicly available information

Chunfang Jian

Longyan First Affiliated Hospital of Fujian Medical University, Longyan, China.

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2024 in Arthroscopy Techniques
Verified
Journal Article
Open access
MZMinghua Zhang
Minghua Zhang
JLJiajing Lai
Jiajing Lai
DCDaohua Chen
Daohua Chen
CJChunfang Jian
Chunfang Jian
Achieving sufficient attachment of deep rotator cuff tissue to the footprint area on the greater tubercle of the humerus is essential for functional recovery, yet the optimal approach remains uncertain. We introduce a surgical technique for rotator cuff tear repair using a spinal needle to penetrate deep rotator cuff tissue under direct arthroscopic visualization. After trimming the torn edge, an arthroscope is inserted into the joint cavity through a posterior portal, and a hole is drilled into the humeral head cartilage margin using an upper approach, facilitating the implantation of an internal shoulder row nail. A spinal needle is used to introduce a No. 2 polydioxanone (PDS; Johnson & Johnson) line through sufficient deep rotator cuff tissue. Graspers are then used to extract the stitch and PDS together through the anterolateral opening. Once the PDS is knotted, the stitch is introduced into the rotator cuff. This process is replicated to insert additional stitches into the rotator cuff. Our proposed technique, involving a spinal needle under direct visualization, ensures sufficient coverage of the deep rotator cuff tissue over the footprint area and promotes the healing of the repaired rotator cuff. This method is safe, effective, convenient, and reproducible. Technique Video: video See video under supplementary data.

18 June 2025 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
MZMinghua Zhang
Minghua Zhang
DCDongfeng Chen
Dongfeng Chen
DCDaohua Chen
Daohua Chen
JLJiajing Lai
Jiajing Lai
CJChunfang Jian
Chunfang Jian
In arthroscopic rotator cuff repair, satisfactory postoperative outcomes can be achieved by simplifying the surgical procedure and ensuring proper integration of the deep rotator cuff tissue with the footprint area for tendon reconstruction. The purpose of this study was to evaluate the short-term efficacy of arthroscopic spinal needle sutures for the repair of rotator cuff tears. This retrospective study included a cohort of 81 patients with rotator cuff tears who underwent arthroscopic suture repair using a spinal needle between January 2021 and March 2021, with a minimum follow-up duration of 27 months. Pre- and postoperative Constant–Murley Score (CMS), University of California–Los Angeles Shoulder Score (UCLASS), Visual Analog Scale (VAS) scores, and range of motion (ROM) measurements, including active forward flexion, abduction, and lateral rotation angles, were compared to assess shoulder anatomy, function, strength, and subjective patient satisfaction. Statistically significant improvements were observed in CMS, UCLASS, VAS, and ROM postoperatively (P = 0.000). The excellent or good outcome rate was 81.48%. Age and preoperative ROM significantly influenced outcomes (P = 0.039 and P = 0.006), respectively, whereas gender and pain duration did not show a significant effect (P > 0.05). Patients older than 30 years demonstrated significantly better results (P < 0.001). The use of a spinal needle for rotator cuff tear repair under direct arthroscopic visualization is a safe, efficient, and clinically effective technique. IV Not applicable.

8 August 2025 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
MZMinghua Zhang
Minghua Zhang
DCDongfeng Chen
Dongfeng Chen
DCDaohua Chen
Daohua Chen
JLJiajing Lai
Jiajing Lai
CJChunfang Jian
Chunfang Jian

1 July 2026 in Scientific Reports
Verified
Journal Article
Open access
MZMinghua Zhang
Minghua Zhang
DCDongfeng Chen
Dongfeng Chen
CZChangrui Zhong
Changrui Zhong
DCDaohua Chen
Daohua Chen
YLYing Li
Ying Li
CJChunfang Jian
Chunfang Jian
To determine the effects of platelet-rich plasma (PRP) on pain relief, functional recovery, and graft maturation after anterior cruciate ligament reconstruction (ACLR). Therapeutic RCT. In this randomized controlled trial (RCT), 54 patients undergoing ACLR were prospectively allocated to the PRP group (n = 27) or the control group (n = 27). PRP was injected around the graft during surgery and at 1, 2, and 3 weeks postoperatively in the PRP group; the rest of the surgical and rehabilitation protocol was the same in both groups. The primary efficacy endpoint was the time to achieve significant pain relief (defined as a visual analog scale [VAS] score ≤ 3). The secondary endpoints were the Lysholm score, International Knee Documentation Committee (IKDC) score, and graft signal intensity on magnetic resonance imaging (MRI) at the 12-month follow-up. The primary endpoint-time to achieve meaningful pain relief (VAS ≤ 3)-was not met; no significant difference was found between the 2 groups (2.56 ± 1.05 vs. 2.93 ± 1.27 days, P = 0.248). However, the PRP group showed higher Lysholm scores (91.04 ± 6.44 vs. 85.74 ± 10.60, P = 0.031) and IKDC scores (92.30 ± 5.53 vs. 83.59 ± 13.11, P = 0.02), and reduced MRI signal intensity in the graft midbody (P = 0.021) and distal third (P = 0.006). The primary endpoint was not met: PRP did not accelerate early pain relief (time to VAS ≤ 3) compared with the control group. However, PRP significantly improved short-term functional outcomes and promoted graft ligamentization after ACLR, independent of graft diameter.