Nelcí Helena Maia Gutierrez

Nelcí Helena Maia Gutierrez

Auto-generated profile, based on publicly available information

Nelcí Helena Maia Gutierrez

Universidade Estadual de Maringá, Brasil

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2021 in Soils and Rocks
Verified
Journal Article
Closed access
PDF file
RZRenan F. B. Zanin
Renan F. B. Zanin
APAna C. C. Padilha
Ana C. C. Padilha
FPFlávia G. P. Pelaquim
Flávia G. P. Pelaquim
NGNelcí H. M. Gutierrez
Nelcí H. M. Gutierrez
RTRaquel S. Teixeira
Raquel S. Teixeira
Different fluids can permeate the soil collapsing at various levels of severity depending on their physicochemical characteristics. This work evaluated the effect of pH and electrical conductivity (ECf) of different soaking fluids on the collapsible behavior of a lateritic silty clay. Double and single oedometer tests were performed using four chemically distinct soaking fluids (water, leachate and two laboratory solutions, one alkaline and one acid). The collapse index (I) was evaluated according to two criteria. In addition, physical-chemical analysis of the soil and measurements of pH and ECf were done. According to the results, the soil is collapsible for the four soaking fluids. No single relationship was found between fluid pH and collapse index, although, the highest values of collapse index were found in the tests soaked with alkaline and acid solutions. Finally, a unique direct relationship was found between the collapse index and the ECf, that is, the higher this parameter, the higher the collapse index value.

1 January 2025 in Ambiente Construído
Verified
Journal Article
Open access
PDF file
FVFernanda Assunção Valim
Fernanda Assunção Valim
NGNelci Helena Maia Gutierrez
Nelci Helena Maia Gutierrez
KZKatia Cristina Zanatta
Katia Cristina Zanatta
LSLeonardo Martins e Silva
Leonardo Martins e Silva
WSWhite José dos Santos
White José dos Santos
The application of recycled sand from construction and demolition waste (CDW) in the soil-cement mixture for the manufacture of modular bricks for structural masonry was investigated, evaluating bricks and prisms. Firstly, the optimum moisture content was analyzed by analyzing the additions of CDW with 20%, 40%, 50% and 60%, by mass, in the soil mixture with 10% cement. The bricks were evaluated for their geometric characteristics, compressive strength, density and water absorption. The compressive strength of the bricks was analyzed at different ages (7, 14, 28, 56 and 530 days). The prisms (250.75mm x 126.41 mm x 137.16 mm), with a conventional 5 mm mortar joint, were evaluated for compressive strength, modulus of elasticity and failure mode, aged 530 days. The results demonstrated the feasibility of using CDW, which increases the compressive strength of the bricks, but makes molding difficult, as it reduces initial cohesion. The efficiency factor of the prisms was 57%. The failure mode observed was tension in the bricks and subsequent propagation of cracks in the joints - behavior similar to materials with brittle rupture. Brazilian standards approached the mechanical behavior of the material.

5 December 2023 in Geosul
Verified
Journal Article
Open access
PDF file
AOAndressa Oliveira
Andressa Oliveira
NGNelcí Helena Maia Gutierrez
Nelcí Helena Maia Gutierrez
GNGuilherme Tsuyoshi Nonose
Guilherme Tsuyoshi Nonose
As propriedades de um solo são influenciadas pelas condições geológicas, climáticas locais e mineralogia. O perfil de solo analisado, resultante de basalto, é constituído por dois conjuntos: superior (solo evoluído – Latossolo) e inferior (saprolito). Com o aumento da profundidade, os valores de NSPT e umidade tenderam a crescer e os teores de argila reduziram, enquanto os índices de plasticidade aumentaram, pressupondo a existência de um bloqueio da argila no conjunto superior. O solo evoluído exibiu uma distribuição de poros bimodal com predomínio de poros interagregados (70%) e redução no tamanho dos poros maiores com o aumento da profundidade. Essas peculiaridades são úteis na definição de parâmetros geotécnicos e justificam valores, nem sempre condizentes com os esperados, para os solos finos.

25 October 2023 in ENCONTRO NACIONAL DE APROVEITAMENTO DE RESÍDUOS NA CONSTRUÇÃO
Verified
Conference Paper
Open access
PDF file
FVFernanda Valim
Fernanda Valim
WSWhite José dos Santos
White José dos Santos
NGNelci Gutierrez
Nelci Gutierrez
LSLeonardo Martins e Silva
Leonardo Martins e Silva
KZKatia Cristina Zanatta
Katia Cristina Zanatta
Nesta pesquisa investigou-se a resistência à compressão e o módulo de elasticidade de prismas confeccionados com tijolos vazados de solo-cimento-RCD (50%-10%-50%, em massa), com idade avançada (530 dias), unidos por uma junta de argamassa de assentamento convencional de 5 mm. Realizou-se a caracterização do solo e da mistura do Solo-Cimento-RCD. Avaliou-se a resistência à compressão, módulo de elasticidade e o modo de falha dos prismas. O fator de eficiência dos prismas foi de 57%, valor esperado e condizente com outros autores. O modo de falha observado foi de tração nos tijolos e posterior propagação de trincas nas juntas, apresentando comportamento similar a materiais de ruptura frágil. As equações propostas pela normalização brasileira para tijolos de concreto foram as que obtiveram maior proximidade com os valores encontrados nessa pesquisa. Ressalta-se, contudo, que o comportamento mecânico desse tipo de alvenaria precisa, ainda, ser melhor estudado.