9 November 2016 in Journal of Medical Imaging and Radiation Oncology
LHLois Charlotte Holloway
MJMichael Geoffrey Jameson
+1
8 September 2016 in Journal of Applied Clinical Medical Physics
The purpose of this study was to determine the impact of magnetic resonance imaging (MRI) geometric distortions when using MRI for target delineation and planning for whole-breast, intensity-modulated radiotherapy (IMRT). Residual system distortions and combined systematic and patient-induced distortions are considered. This retrospective study investigated 18 patients who underwent whole-breast external beam radiotherapy, where both CT and MRIs were acquired for treatment planning. Distortion phantoms were imaged on two MRI systems, dedicated to radiotherapy planning (a wide, closed-bore 3T and an open-bore 1T). Patient scans were acquired on the 3T system. To simulate MRI-based planning, distortion maps representing residual system distortions were generated via deformable registration between phantom CT and MRIs. Patient CT images and structures were altered to match the residual system distortion measured by the phantoms on each scanner. The patient CTs were also registered to the corresponding patient MRI scans, to assess patient and residual system effects. Tangential IMRT plans were generated and optimized on each resulting CT dataset, then propagated to the original patient CT space. The resulting dose distributions were then evaluated with respect to the standard clinically acceptable DVH and visual assessment criteria. Maximum residual systematic distortion was measured to be 7.9 mm ( ) and 11.9 mm ( ) for the 3T and 1T scanners, respectively, which did not result in clinically unacceptable plans. Eight of the plans accounting for patient and systematic distortions were deemed clinically unacceptable when assessed on the original CT. For these plans, the mean difference in PTV (volume receiving 95% prescription dose) was and for right- and left-sided patients, respectively. Residual system distortions alone had minimal impact on the dosimetry for the two scanners investigated. The combination of MRI systematic and patient-related distortions can result in unacceptable dosimetry for whole-breast IMRT, a potential issue when considering MRI-only radiotherapy treatment planning. PACS number(s): 87.61.-c, 87.57.cp, 87.57.nj, 87.55.D-
1 December 2020 in Technical Innovations & Patient Support in Radiation Oncology
While there is evidence to show the positive effects of automation, the impact on radiation oncology professionals has been poorly considered. This study examined radiation oncology professionals’ perceptions of automation in radiotherapy planning. An online survey link was sent to the chief radiation therapists (RT) of all Australian radiotherapy centres to be forwarded to RTs, medical physicists (MP) and radiation oncologists (RO) within their institution. The survey was open from May-July 2019. Participants were 204 RTs, 84 MPs and 37 ROs (response rates ∼10% of the overall radiation oncology workforce). Respondents felt automation resulted in improvement in consistency in planning (90%), productivity (88%), quality of planning (57%), and staff focus on patient care (49%). When asked about perceived impact of automation, the responses were; will change the primary tasks of certain jobs (66%), will allow staff to do the remaining components of their job more effectively (51%), will eliminate jobs (20%), and will not have an impact on jobs (6%). 27% of respondents believe automation will reduce job satisfaction. 71% of respondents strongly agree/agree that automation will cause a loss of skills, while only 25% strongly agree/agree that the training and education tools in their department are sufficient. Although the effect of automation is perceived positively, there are some concerns on loss of skillsets and the lack of training to maintain this. These results highlight the need for continued education to ensure that skills and knowledge are not lost with automation.
1 November 2016 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
13 August 2015 in Journal of Medical Imaging and Radiation Oncology
18 June 2022 in Journal of Medical Radiation Sciences
Introduction: The magnitude and impact of rotational error is unclear in rectal cancer radiation therapy. This study evaluates rotational errors in rectal cancer patients, and investigates the feasibility of planning target volume (PTV) margin reduction to decrease organs at risk (OAR) irradiation.Methods: In this study, 10 patients with rectal cancer were retrospectively selected. Rotational errors were assessed through image registration of daily cone beam computed tomography (CBCT) and planning CT scans. Two reference treatment plans (TPR) with PTV margins of 5 mm and 10 mm were generated for each patient. Pre‐determined rotational errors (±1°, ±3°, ±5°) were simulated to produce six manipulated treatment plans (TPM) from each TPR. Differences in evaluated dose‐volume metrics between TPR and TPM of each rotation were compared using Wilcoxon Signed‐Rank Test. Clinical compliance was investigated for statistically significant dose‐volume metrics.Results: Mean rotational errors in pitch, roll and yaw were −0.72 ± 1.81°, −0.04 ± 1.36° and 0.38 ± 0.96° respectively. Pitch resulted in the largest potential circumferential displacement of clinical target volume (CTV) at 1.42 ± 1.06 mm. Pre‐determined rotational errors resulted in statistically significant differences in CTV, small bowel, femoral heads and iliac crests (P < 0.05). Only small bowel and iliac crests failed clinical compliance, with majority in the PTV 10 mm margin group.Conclusion: Rotational errors affected clinical compliance for OAR dose but exerted minimal impact on CTV coverage even with reduced PTV margins. Both PTV margin reduction and rotational correction decreased irradiated volume of OAR. PTV margin reduction to 5 mm is feasible, and rotational corrections are recommended in rectal patients to further minimise OAR irradiation.