S. Semychayevsky

S. Semychayevsky

Auto-generated profile, based on publicly available information

S. Semychayevsky

Institute of Public Administration and Research in Civil Protection

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Scientific bulletin: Сivil protection and fire safety
Verified
Journal Article
Closed access
PDF file
SSS Semychayevsky
S Semychayevsky
VPV Prisyajnyuk
V Prisyajnyuk
MYM Yakimenko
M Yakimenko
MOM Osadchuk
M Osadchuk
Among the technical means intended for transportation of fire extinguishing substances to the fire center, the main role is definitely played by delivery fire hoses. At present, the Civil Protection Rescue Service units use mainly pressure fire hoses type "T" (for fire-rescue vehicles) with a diameter of 51 mm and 77 mm, the technical condition of which often does not meet the established requirements, which may not withstand the pressure developing pumps, even traditionally used fire-rescue vehicles during firefighting. The use of such hoses in extinguishing real fires can lead to limited opportunities, reduce the effectiveness of operational and tactical actions of the Civil Protection Rescue Service units, as well as expose personnel to danger. The requirements of the State Standard of Ukraine 2273:2006 in Ukraine are outdated and do not meet the practical needs of today. Given the fact that in the leading countries of the world there are new types of fire hoses and technologies for their creation, as well as due to the fact that adopted in Ukraine State Standard of Ukraine EN 15889: 2017 does not apply to fire-fighting layflat delivery hoses for fire-rescue vehicles, the issue of developing a national standard for this type of fire hoses is relevant. In addition, the European normative document CEN / TR 16099 states that there is no single standard in the European Union that would establish technical requirements for "fire-fighting layflat delivery attack", ie those used with fire and rescue vehicle pumps. In EU countries, this issue is regulated by separate national standards of member states. Confirmation of this approach is the German national standard DIN 14811-2008 / A1-2012, A2-2014. The urgency of developing a national standard regulating the general technical requirements and test methods for fire-fighting layflat delivery hoses for fire-rescue vehicles is given. The modern approaches of the European Union to the establishment of technical requirements and methods for assessing the quality of such hoses are analyzed. The possibility of applying these approaches at the national level has been identified. .

30 June 2026 in Science Technologies Innovation
Verified
Journal Article
Closed access
VPV. V. Prysiazhniuk
V. V. Prysiazhniuk
SSS. V. Semychaievskyi
S. V. Semychaievskyi
MYM. L. Yakimenko
M. L. Yakimenko
MOM. V. Osadchuk
M. V. Osadchuk
VSV. L. Sydorenko
V. L. Sydorenko
The article substantiates the need to conduct research aimed at determining and assessing ergonomic quality indicators of firefighter protective equipment in accordance with the European classification and modern approaches to the evaluation of personal protective equipment. Particular attention is paid to the analysis of structural elements of protective equipment in order to improve its effectiveness during operation by operational units of the State Emergency Service of Ukraine. The main structural parameters that should be taken into account when assessing ergonomic indicators are identified to ensure an adequate level of protection and to reduce the negative impact on the health of firefighters and rescuers during the performance of assigned tasks. The main quality indicators and criteria used for the assessment of ergonomic properties of firefighter protective equipment are presented. It is established that the key ergonomic indicators include wearing comfort, reliability and functionality of fasteners, clarity and visibility during work, compatibility with other personal protective equipment, freedom of movement, and proper fit. It is determined that the assessment of ergonomic properties is carried out through practical testing of protective equipment involving the performance of typical firefighting and rescue activities. The main reasons for declaring firefighter protective equipment unacceptable based on the results of ergonomic testing are identified. The results of ergonomic studies of firefighter helmets conducted by American scientists are presented. Deficiencies in the current regulatory documents regarding the regulation of ergonomic testing of firefighter and rescuer helmets, firefighter gloves, hoods, and protective and heat-reflective firefighter clothing are revealed. Directions for further research aimed at improving the requirements for the quality indicators of these products and developing national standards of Ukraine harmonized with European standards at the IDT (identical) level are outlined.

26 March 2021 in Municipal economy of cities
Verified
Journal Article
Closed access
PDF file
VPV. Prisyajnyuk
V. Prisyajnyuk
SSS. Semychayevsky
S. Semychayevsky
MYM. Yakimenko
M. Yakimenko
MOM. Osadchuk
M. Osadchuk
During the elimination of emergencies, fires and their consequences, units of the State Emergency Service of Ukraine work in a specific environment, which is due to adverse factors affecting them. Fire hazards are manifestations that cause or may lead to burns, poisoning by volatile combustion products or injury or death, causing material and other damage. Dangerous factors of fire include: fever, smoke, deterioration of the gas environment. To date, a number of different (both in terms of technical characteristics and type) special protective equipment is used to perform the tasks assigned by the State Emergency Service of Ukraine, which may not always protect the firefighter from the effects of certain dangerous factors that occur in a fire. The current national standards in Ukraine set only the minimum technical requirements for such equipment, which are insufficient to identify substandard products that fall into the equipment of these units. Therefore, in order to prevent the use of such low-quality protective equipment, it is necessary to study all possible risks and dangers that arise during emergency response by the State Emergency Service of Ukraine and develop reasonable requirements for special protective equipment and appropriate test methods. The above determines the relevance of the study aimed at implementing in Ukraine modern requirements for quality indicators of special protective equipment for firefighters, methods and procedures for their evaluation. This is necessary to implement the requirements of the Technical Regulations for construction products, buildings and structures in order to ensure the safety of rescue teams during firefighting. In order to assist in solving this problem at the Institute of Public Administration and Research on Civil Protection by order of the State Emergency Service of Ukraine plans to conduct research on "Substantiation of quality indicators and methods of assessing special protective equipment firefighter" (topic code: Protective equipment - indicators quality "), which will develop a draft national standard of Ukraine, which sets requirements for quality indicators of special protective equipment for firefighters, methods and procedures for their evaluation.

26 March 2021 in Municipal economy of cities
Verified
Journal Article
Closed access
PDF file
VPV. Prisyajnyuk
V. Prisyajnyuk
SSS. Semychayevsky
S. Semychayevsky
MYM. Yakimenko
M. Yakimenko
MOM. Osadchuk
M. Osadchuk
The danger to society caused by the consequences of natural disasters tends to increase despite the general technical progress and the application of measures to prevent them and combat them. Every year the number of victims, in particular, from floods increases by an average of 6%. Flooding in certain areas can occur due to floods and inundations. Floods are natural processes that occur in the biosphere and affect the planet for millennia. Flood is a significant flooding of the area due to rising water levels in rivers, lakes, reservoirs, caused by downpours, spring snowmelt, wind surges, destruction of dams, dams and more. Floods cause great material damage and casualties. The water level in reservoirs depends on many different factors. All over the world, experts conduct long-term observations, tracking all seasonal changes, and collect data for forecasting. Floods and their causes are well studied. The main causes of these disasters are: - prolonged rains; - melting snow; - raising the bottom; - strong winds and storms; - groundwater; Thus, the issue of using modern technical means of protection against flooding of territories and objects of various purposes is relevant. A number of publications consider current trends in effective flood risk management planning in the European Union and describe the catastrophic consequences of floods and ways to combat them, and so on. At the same time, these studies do not contain data on testing and implementation in Ukraine of modern technical means to combat floods in the EU. To address these issues, the Institute of Public Administration and Research on Civil Defense commissioned by the State Service of Ukraine for Emergencies has developed a method of testing water-absorbing devices designed for: - flood protection; - changes in the direction of water flow during floods, torrential rains, melting snow, etc. - removal of water from flooded areas (basements, garages, etc.); - elimination of environmental accidents (spills of oil, diesel fuel and other chemicals). Developed by the Institute of Public Administration and Research on Civil Protection, the method of testing water-absorbing means will allow in the future to test and assess the suitability of such technical means for use by fire and rescue units when performing tasks to remove water from flooded areas and create barriers to water. time of protection against floods, changes in the direction of water flow during floods, torrential rains, melting snow, etc.

27 June 2018 in Scientific Bulletin of UNFU
Verified
Journal Article
Open access
VPV. V. Prisyazhnuk
V. V. Prisyazhnuk
SSS. V. Semichaevsky
S. V. Semichaevsky
MOM. V. Osadchuk
M. V. Osadchuk
OMO. V. Milyutin
O. V. Milyutin
BKB. I. Krivoshey
B. I. Krivoshey
Розглянуто актуальність питання застосування підрозділами ОРСЦЗ ДСНС України переносних засобів димо- та тепловидалення (пожежних димососів). Встановлено, що нагнітання свіжого повітря у приміщення є найефективнішим порівняно з відсмоктуванням загазованого повітря. Зазначено, що застосування комбінованого способу управління газовими потоками за допомогою пожежних димососів дає змогу знизити температурний вплив на людину на основних шляхах евакуації. З'ясовано фактори, що підвищують ефективність гасіння пожеж із застосуванням пожежних димососів. Наведено основні ознаки, за якими класифікують пожежні димососи. Встановлено основні критерії для вирішення питання компоновки переносного засобу димо- та тепловидалення (пожежного димососу). Оптимальні параметри за масою, габаритні розміри та характеристики двигуна буде визначено за результатами аналізу зарубіжних розробок у цій галузі. Наведено порівняння основних технічних характеристик пожежних димососів часів Радянського Союзу із відповідними сучасними зразками, які застосовують у провідних країнах світу. Зазначено потреба виконання науково-дослідної роботи, щоб обґрунтувати технічні вимоги до сучасних переносних пожежних димососів і розробити пропозиції з підвищення ефективності гасіння пожеж з їх застосуванням. Визначено основні завдання, які необхідно вирішити в рамках виконання науково-дослідної роботи.

1 October 2021 in Municipal economy of cities
Verified
Journal Article
Open access
PDF file
VPV. Prisyajnyuk
V. Prisyajnyuk
SSS. Semychayevsky
S. Semychayevsky
VSV. Svirsky
V. Svirsky
OKO. Kornienko
O. Kornienko
Pressure fire hoses are one of the main types of fire-fighting equipment, on the serviceable condition of which depends the operational activities of fire and rescue units and successful firefighting. At present, Ukraine has entered into force with (01.08.2021) the national standard, which contains modern European requirements for assessing the quality of flat-hose fire hoses for fire and rescue vehicles. This standard was developed by the Institute of Public Administration and Research in Civil Defense in the framework of research work "Fire hoses – test methods" and adopted by order of SE "UkrNDNC" from 23.03.2021 № 107. In order to assist in solving this problem, the Institute of Public Administration and Research in Civil Defense put into operation, tested and verified the installation for testing fire pressure hoses, which will check the quality of pressure flat hose for fire and rescue vehicles in accordance with modern European requirements. The installation is intended for tests of pressure fire hoses carried out on the following quality indicators: working, test and burst pressure; abrasion resistance; resistance to hot objects; resistance to open flame. The unit is operated at air temperature from 10 ° С to 25 ° С and relative humidity from 15% to 90%. The installation is a metal table, which consists of two levels (upper and lower). The main part of the tests is to be performed at the upper level with the help of three removable modules. The lower level provides one stationary module on which tests for working, test and burst pressure are carried out. The upper level of the installation is designed to test pressure fire hoses for the following quality indicators: resistance to surface abrasion, resistance to point abrasion, resistance to hot objects and resistance to open flames. For versatility and convenience of work on installation on the top level of a table the possibility of change of modules depending on their need is provided. The lower level of the installation is intended for carrying out tests of pressure fire hoses on quality indicators – working and test pressure, bursting pressure. At the lower level of the metal table is a rectangular metal box, which has a closing lid. During the tests, the sample of the test sleeve is automatically filled with water, which drains after the test. To fix the samples of fire hoses of different diameters (25, 32, 38, 51, 66, 77, 100, 125 and 150) mm, the installation includes special cones and plates.