Makaram Singaperumal

Makaram Singaperumal

Auto-generated profile, based on publicly available information

Makaram Singaperumal

Indian Institute of Technology

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2007 in Industrial Robot: the international journal of robotics research and application
Verified
Journal Article
Closed access
PDF file
SMSreekumar Muthuswamy
Sreekumar Muthuswamy
TNT. Nagarajan
T. Nagarajan
MSM. Singaperumal
M. Singaperumal
MZMatteo Zoppi
Matteo Zoppi
RMR. Molfino
R. Molfino
Purpose – The purpose of this paper is to review the current application areas of shape memory alloy (SMA) actuators in intelligent robotic systems and devices. Design/methodology/approach – This paper analyses how actuation and sensing functions of the SMA actuator have been exploited and incorporated in micro and macro robotic devices, developed for medical and non-medical applications. The speed of response of SMA actuator mostly depends upon its shape and size, addition and removal of heat and the bias force applied. All these factors have impact on the overall size of the robotic device and the degree of freedom (dof) obtained and hence, a comprehensive survey is made highlighting these aspects. Also described are the mechatronic aspects like the software and hardware used in an industrial environment for the control of such nonlinear actuator and the type of sensory feedback devices incorporated for obtaining better control, positioning accuracy and fast response. Findings – SMA actuators find wide applications in various facets of robotic equipments. Selecting a suitable shape, fast heating and cooling method and better intelligent control technique with or without feedback devices could optimize its performance. Research limitations/implications – The frequency of SMA actuation purely depends on the rate of heat energy added to and removed from the actuator, which in turn depends upon interrelated nonlinear parameters. Practical implications – For increasing the dof of robots, number of actuators also have to be increased that leads to complex control problems. Originality/value – Explains the suitability of SMA as actuators in smart robotic systems, possibility of miniaturisation. It also highlights the difficulties faced by the SMA research community.

1 February 2010 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
SKS. Karunanidhi
S. Karunanidhi
MSM. Singaperumal
M. Singaperumal


14 February 2000 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
GUGanesha Udupa
Ganesha Udupa
MSM Singaperumal
M Singaperumal
RSR S Sirohi
R S Sirohi
MKM P Kothiyal
M P Kothiyal
Surface topography and, in particular, roughness and form, plays an important role in determining the functional performance of engineering parts. The measurement and understanding of surface topography is rapidly attracting the attention of the physicist, the biologist and the chemist as well as the engineer. Optics in general played an important role in measurement and, with the advent of opto-mechatronics, it is once again at the forefront of measurement. In this paper, the principles and performance of a confocal microscope, together with the measurement system, are described. Suitable fixtures are developed and integrated with the computer system for generating three-dimensional surface and form data. Software for data acquisition, analysis of various parameters including new parameters and visualization of surface geometrical features has been developed. Both the intensity and the auto-focus methods are used to measure two-dimensional surface roughness by use of the system and results are presented. The measurement and characterization of three-dimensional surface topography and form error will be presented in part II of this paper.

1 April 2007 in Journal of Zhejiang University-SCIENCE A
Verified
Journal Article
Closed access
PDF file
SMSreekumar Muthuswamy
Sreekumar Muthuswamy
MSM. Singaperumal
M. Singaperumal
TNT. Nagarajan
T. Nagarajan
MZMatteo Zoppi
Matteo Zoppi
RMR. Molfino
R. Molfino
This paper reviews recent developments in nonlinear control technologies for shape memory alloy (SMA) actuators in robotics and their related applications. SMA possesses large hysteresis, low bandwidth, slow response, and non-linear behavior, which make them difficult to control. The fast response of the SMA actuator mostly depends upon, (1) type of controller, (2) rate of addition and removal of heat, and (3) shape or form of the actuator. Though linear controllers are more desirable than nonlinear ones, the review of literature shows that the results obtained using nonlinear controllers were far better than the former one. Therefore, more emphasis is made on the nonlinear control technologies taking into account the intelligent controllers. Various forms of SMA actuator along with different heating and cooling methods are presented in this review, followed by the nonlinear control methods and the control problems encountered by the researchers.

5 March 2014 in Materials and Manufacturing Processes
Verified
Journal Article
Closed access
RSR. K. Sahu
R. K. Sahu
SHSomashekhar S. Hiremath
Somashekhar S. Hiremath
PMP V Manivannan
P V Manivannan
MSM. Singaperumal
M. Singaperumal
The present article describes the generation of copper nanoparticles in the base fluid using developed micro-electrical discharge machining (micro-EDM) process. Micro-EDM was performed with various operating parameters such as voltage, current, pulse width and duty factor. To prevent agglomeration and coagulation of nanoparticles, polyvinyl alcohol (PVA) and polyethylene glycol (PEG) are used as stabilizers. The characterization of the generated copper nanofluid is done by energy dispersive analysis by X-rays, selected area electron diffraction pattern and transmission electron microscope followed by the study of thermal conductivity and viscosity of nanofluid using KD-2 pro device and falling ball type viscometer. The viscosity measurement enables to determine the dispersion stability of copper nanofluids. The experimental results show that the mean size of generated spherical copper nanoparticles is found to be less than 10 nm. It was observed that the thermal conductivity of copper–de-ionized (DI) water, copper–DI water with PVA and PEG nanofluids are 6%, 14% and 15% are higher than that of pure DI water. Also, it was found that there is a reduction of 96% and 99.9% in the sedimentation velocity of copper nanoparticles in copper–DI water with PVA and PEG nanofluid when compared to copper–DI water nanofluid resulting in excellent dispersion stability of the nanoparticles in copper–DI water with PEG nanofluid rather than PVA nanofluid.