Wiebke Mainville

Wiebke Mainville

Auto-generated profile, based on publicly available information

Wiebke Mainville


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2026 in International Communications in Heat and Mass Transfer
Verified
Journal Article
Open access
MVMikael Vaillant
Mikael Vaillant
VFVictor Oliveira Ferreira
Victor Oliveira Ferreira
WMWiebke Mainville
Wiebke Mainville
JLJean-Michel Lamarre
Jean-Michel Lamarre
VRVincent Raymond
Vincent Raymond
BBBruno Blais
Bruno Blais

28 February 2026 in HardwareX
Verified
Journal Article
Open access
VFVictor Oliveira Ferreira
Victor Oliveira Ferreira
WMWiebke Mainville
Wiebke Mainville
VRVincent Raymond
Vincent Raymond
JLJean-Michel Lamarre
Jean-Michel Lamarre
AHAntoine Hamel
Antoine Hamel
BBBruno Blais
Bruno Blais
This work proposes an experimental unit that realizes a multi-input, multi-output manifold thermal management technology. The proposed setup is designed for experiments aimed at controlling spatiotemporal temperature distribution. Temperature control is achieved by impinging coolant fluid jets, leveraging a manifold of channels targeted to the surface. The direction of the fluid is controlled by shifting the role of channels between inputs, outputs, or closed states. Files associated with this work include Computer-Aided Design (CAD) STEP files, Gerber files to manufacture a custom Printed Circuit Board (PCB), and a Graphical User Interface (GUI) written in Python. A step-by-step guide to assembling the experimental setup is provided, alongside instructions to interact with the setup through the GUI for real-time tracking. Validation experiments characterize the dynamic performance of the system, demonstrating a temperature reduction of 6 °C in response to a 54 L min−1 step change in flow rate, with a settling time of 400 s. Setpoint tracking capability is demonstrated through a representative proportional–integral (PI) control experiment, which consistently reaches the target temperature with high reproducibility across repeated trials. Disturbance rejection performance is further validated by maintaining a 100 °C temperature setpoint under spatially varying heat loads using PI control. With a total component cost of approximately $14,000 USD, the active cooling device presents a safe, flexible, and complete design, allowing for lab-scale assessment of the performance of custom temperature control strategies using enclosed impinging jets.