Zhiru Zhou

Zhiru Zhou

Auto-generated profile, based on publicly available information

Zhiru Zhou

Worcester Polytechnic Institute

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
ZZZhiru Zhou
Zhiru Zhou
FCFeiyun Cui
Feiyun Cui
QWQi Wen
Qi Wen
SZSusan Zhou
Susan Zhou
Cancer cell migration through tissue pores and tracks into the bloodstream is a critical biological step for cancer metastasis. Although in vivo studies have shown that expression of vimentin can induce invasive cell lines, its role in cell cytoskeleton reorganization and cell motility under in vitro physical confinement remains unknown. Here, a microfluidic device with cell culture chamber and collagen-coated microchannels was developed as an in vitro model for physiological confinement environments. Using this microchannel assay, we demonstrated that the knockdown of vimentin decreases 3T3 fibroblast cell directional migration speed in confined microchannels. Additionally, as cells form dynamic membranes that define the leading edge of motile cells, different leading edge morphologies of 3T3 fibroblast and 3T3 vimentin knockdown cells were observed. The leading edge morphology change under confinement can be explained by the effect of vimentin on cytoskeletal organization and focal adhesion. The microfluidic device integrated with a time-lapse microscope provided a new approach to study the effect of vimentin on cell adhesion, migration, and invasiveness.

1 September 2019 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
ZZZhiru Zhou
Zhiru Zhou
SZSusan Zhou
Susan Zhou
We successfully fabricated Cu-CuO/TNT electrode by coating the Cu-CuO nanoparticles onto TiO2 nanotube arrays surface through electrochemical deposition method, which is easy to operate and fast procedure. After the electrochemical deposition, Cu-CuO nanoparticles with a diameter of ~200nm were well dispersed onto TNT surface, which then given a smooth interaction surface and a 3D nanostructure with high uniformity. The as prepared Cu-CuO/TNT electrode was then used for non-enzymatic in vitro detection of glucose in sodium hydroxide (NaOH) solution. The non-enzymatic glucose sensor exhibits great analytical performance with wide linear range between 0.2-90mM, high sensitivity of 234 μA mM-1cm-2and low limit of detection of 0.019. Other than that, it also shows great selectivity toward glucose in presence of other interference species such as ascorbic acid(AA), dopamine(DA), uric acid(UA), lactose, sucrose, and fructose. The wide linear range between 0.2-90mM of the sensor is really potential to be used for clinical and biopharmaceutical application. For diabetic patient, blood glucose concentrations can increase up to 40mM after glucose intake. For biopharmaceutical industry, glucose concentration can increase up to 80mM in the cell culture bioreactor. Current sensing platform described in a large part of scientific publication have little if no chance for application as their linear range is often outside the physiological range. In light of this information, the proposed non-enzymatic glucose sensor can be used for continuous monitoring of glucose in most applications. Figure 1

1 May 2020 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
FCFeiyun Cui
Feiyun Cui
ZZZhiru Zhou
Zhiru Zhou
HFHanping Feng
Hanping Feng
SZSusan Zhou
Susan Zhou
A polyurethane (PU) nanospiked gold electrode-based label-free electrochemical immunosensor for Clostridium difficile (C. difficile) toxin B detection was developed. Different from nanomaterials-modified electrode, the PU nanospiked gold electrode was fricated by soft lithography directly. The morphology of the nanospiked electrode was characterized by scanning electron microscope (SEM), and its good electrochemical performance was demonstrated by cyclic voltammetry (CV) as well as differential pulse voltammetry (DPV). Then, the PU nanospiked gold electrode-based immunosensor was developed by fixing anti-toxin B single domain antibody on the electrode surface as the receptor. DPV was used as a detection technology for C. difficile toxin B detection. It revealed that the immunosensor has good specificity, repeatability, and stability. Even in a label-free style, the limit of detection for toxin B was 0.5 pg/mL. With the increase of the concentration of toxin B from 1 pg/mL to 130 pg/mL, a linear relationship was observed between the peak current and toxin concentration. Compared with flat PU electrode-based immunosensor, the detection signal of PU nanospiked gold electrode-based immunosensor was amplified about 6 times. Benefitted from its low cost and simple processing, the PU nanospiked gold electrode-based immunosensor can be used a disposable electrochemical sensor for toxin B rapid detection.