Michael Walsh

Michael Walsh

Auto-generated profile, based on publicly available information

Michael Walsh

ITER Organization 6 , Route de Vinon sur Verdon, CS 90 046, 13067 Saint Paul Lez Durance Cedex

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Atoms
Verified
Journal Article
Open access
PDF file
MHManfred von Hellermann
Manfred von Hellermann
MBMaarten de Bock
Maarten de Bock
Oleksandr MarchukOleksandr Marchuk
Oleksandr Marchuk
RDReiter Detlev
Reiter Detlev
SSStanislav Serov
Stanislav Serov
MWMichael Walsh
Michael Walsh
The concept and structure of the Simulation of Spectra (SOS) code is described starting with an introduction to the physics background of the project and the development of a simulation tool enabling the modeling of charge-exchange recombination spectroscopy (CXRS) and associated passive background spectra observed in hot fusion plasmas. The generic structure of the code implies its general applicability to any fusion device, the development is indeed based on over two decades of spectroscopic observations and validation of derived plasma data. Four main types of active spectra are addressed in SOS. The first type represents thermal low-Z impurity ions and the associated spectral background. The second type of spectra represent slowing-down high energy ions created from either thermo-nuclear fusion reactions or ions from injected high energy neutral beams. Two other modules are dedicated to CXRS spectra representing bulk plasma ions (H+, D+, or T+) and beam emission spectroscopy (BES) or Motional Stark Effect (MSE) spectrum appearing in the same spectral range. The main part of the paper describes the physics background for the underlying emission processes: active and passive CXRS emission, continuum radiation, edge line emission, halo and plume effect, or finally the charge exchange (CX) cross-section effects on line shapes. The description is summarized by modeling the fast ions emissions, e.g., either of the α particles of the fusion reaction or of the beam ions itself.

11 June 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DSDmitry Samsonov
Dmitry Samsonov
AKAndrey Kamshilin
Andrey Kamshilin
GMGennadii Marinin
Gennadii Marinin
DTDenis Terentev
Denis Terentev
IKIvan Kirienko
Ivan Kirienko
MWMichael Walsh
Michael Walsh
Basic principles are discussed of a First Mirrors Unit (FMU) design for ITER optical diagnostics, equipped with an RF capacitive coupled discharge cleaning subsystem. A non-tunable RF pre-matcher device is shown to be desirable in the proximity to the discharge load to avoid excessive heating of an in-vessel RF feeder part. A possibility of satisfactory RF pre-matching with a simple non-tunable L-shaped circuit is demonstrated for the experimentally measured RF discharge impedance variation. The structure of an FMU RF power distribution circuit is suggested, consisting of an RF pre-matcher, an RF power meter, and, when required, an RF decoupler of a DC-grounded water-cooled mirror. Planar implementation of an RF pre-matching device is recognized as the most feasible and universal, as a result of analysis of various base element types. Three options of RF-decoupled mirror cooling manifolds are discussed, revealing an optimal selection of their electric and dimensional parameters. A structural implementation of a planar RF pre-matcher ceramic parts fastening is suggested, taking into account their integrity under inertial, neutron and thermal loads expected during ITER operation. Successful pilot tests of the RF pre-matcher performance and structural integrity demonstrate the promise of the described design approach.

19 May 2011 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
SSSergei Shibaev
Sergei Shibaev
GNGraham Naylor
Graham Naylor
RSRory Scannell
Rory Scannell
GMGraham J. McArdle
Graham J. McArdle
MWMichael J. Walsh
Michael J. Walsh
The MAST (Mega-Amp Spherical Tokamak) Thomson scattering diagnostic provides measurements of electron temperature and density at 130 spatial points with ~10 mm resolution across the plasma. Eight 30 Hz 1.6J Nd:YAG lasers have been combined to produce an average sampling rate of 240 Hz with minimum interval >;1 μs. The scattered light signals are registered as polychromator outputs at 1 GHz rate in a short interval around each laser pulse. There are two tasks when real-time system capability is needed: 1) triggering of lasers and acquisition on plasma events to provide higher time resolution; 2) output physical data, electron temperature and density, in real-time for plasma control and other applications. In a standard mode the system works with postshot data acquisition; the physical data are produced as a result of intensive processing including results from other diagnostics. The real-time mode requires a fast processing algorithm and a fast way for gathering and dispatching data. This paper presents the implementation of real-time capabilities and first results of their usage.

1 June 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
DMDidier Mazon
Didier Mazon
MCMaryna Chernyshova
Maryna Chernyshova
AJAxel Jardin
Axel Jardin
YPY. Peysson
Y. Peysson
AWA. Wojenski
A. Wojenski
WTWest Team
West Team
Since the advent of tungsten walls in ITER, the problem of precisely reconstructing the distribution of tungsten (W) concentration in the plasma has become all the more relevant. Among the different possible approaches, those using x-ray measurements seem particularly promising. Indeed, essential plasma parameters can be inferred from x-ray line-integrated measurements such as magnetic equilibrium, electron temperature, concentration of impurities, and their spatial distribution after tomographic inversion. Despite being extremely rich in information, the access to continuous spectral measurements is nevertheless a technical challenge rarely implemented in actual tokamaks. In this work, we review recent work on different techniques dedicated to the inference of the W impurity distribution in WEST plasmas, based on x-ray tomography diagnostics with or without energy discrimination, in particular with semiconductor and gas detectors. For this purpose, synthetic diagnostic tools have been developed for the different used detectors to validate the measurements in the presence of partially ionized W impurities in the core plasma and provide prediction for future applications in ITER.

1 August 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MBMette Bybjerg Brock
Mette Bybjerg Brock
ACAmalia Chambon
Amalia Chambon
CBChristian R. H. Bahl
Christian R. H. Bahl
Antonino PietropaoloAntonino Pietropaolo
Antonino Pietropaolo
MWMichael Walsh
Michael Walsh
AWAnders C. Wulff
Anders C. Wulff
We propose a scalable system of compact, superconducting neutron monitors, which can be embedded in any existing cryogenic infrastructure of a fusion system. The pixel-based nature of the detectors allows them to be placed at intervals following the circumference of a cooled zone, e.g., a field coil, thus allowing for a tomographic measurement of the neutron flux surrounding the plasma. An early stage prototype of the superconducting bolometer is described, and the key results of a previous feasibility study of this prototype performed with cold neutrons are summarized. The bolometer can be adapted for use with fast neutrons by altering the composition and geometry of the neutron-to-heat conversion layer. This paper describes the initial feasibility considerations for implementation in a superconducting tokamak. The sensor is based on a high-temperature superconductor, making it possible to select the operation temperature in the range 1–90 K. Neutron flux numbers were found using the ITER MCNP reference model, and these were embedded in a TOPAS model to find the expected signal measured by the bolometer at the position of a toroidal field coil. The results at the coil position indicate suitable operation levels in terms of the magnitude of the measured signal, with a measurable signal of several ohm, which is much smaller than the saturation energy of the detector. Radiation hardness is estimated and found to be on the order of at least 40 years for the relevant radiation levels. The upcoming investigation activities of the project are described for both radiation testing and analytical modeling.

8 October 2026 in Fusion Engineering and Design
Verified
Journal Article
Closed access
TLTarundeep Kaur Lamba
Tarundeep Kaur Lamba
LML. Moser
L. Moser
MKMartin Kocan
Martin Kocan
MVMartin Vincent
Martin Vincent
YRYan Rong
Yan Rong
MRMukesh Ranjan
Mukesh Ranjan