Marcin Gostyński

Marcin Gostyński

Auto-generated profile, based on publicly available information

Marcin Gostyński

University Clinical Hospital no1, Pomeranian Medical University, Szczecin, Poland

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2024 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Open access
PDF file
KRKatarzyna Radomska
Katarzyna Radomska
MMMichał Mielnik
Michał Mielnik
MGMarcin Gostyński
Marcin Gostyński
EDEdyta Dzięciołowska-Baran
Edyta Dzięciołowska-Baran
Objective: The aim of this study was to determine optimal radiological parameters for assessment of the round window approach in cochlear implantation surgery. Materials and methods: Patients undergoing cochlear implantation at the Department of Otolaryngology in Szczecin, between 2015 and 2022 inclusive, were eligible for the study. Radiological assessments were performed according to eight parameters (seven proposed in the literature) and visibility clinical assessments were made intra-operatively on a scale of 1 to 5 (1 - not visible, 5 - fully visible). Visibility assessments of the round window niche (RWN) and round window membrane (RWM) allowed the difference (RWN minus RWM) to be used as a clinical assessment of the size of the overhang over the round window. Results: Computed tomography images of 57 ears from 52 patients were analyzed in terms of round window access. The study group included 26 females and 26 males, ranging in age from 1 year to 80 years, with a median age of 41 years. In clinical assessment, round window visibility was rated as 5, after removal of the bone overhang, in 69% of patients. Cochlear access through the round window was achieved in 39 (68%) cases, extended access through the round window in 13 (23%) cases and cochleostomy was performed in 5 (9%) cases. Statistically significant ordinal correlations with round-window access were found using one parameter from the literature (Chen_Angle) and from our proposal (RWM_prediction). From parameters describing the bone overhang of the round window, positive correlations (using Kendall rank tests) were found using parameters from the literature (Sarafraz_OH and Mehanna_OH). Conclusions: Radiological measurements describing access to the round window which determine the angle based on the anatomy of the posterior wall of the auditory canal and the position of the facial nerve were found to be of the highest value. Clinical relevance statement: In the future, the use of algorithms for computed tomography evaluation and robot-assisted surgery will require parameters for assessing round window access, for surgery planning and choice of electrode. The parameters proposed by various authors are summarized, allowing researchers to assess their usefulness in further clinical practice.

26 May 2025 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
KRKatarzyna Radomska
Katarzyna Radomska
SSSandra Sadkowska
Sandra Sadkowska
MGMarcin Gostyński
Marcin Gostyński
MLMichał Lubkowski
Michał Lubkowski
JBJowita Biernawska
Jowita Biernawska
SZSławomir Janusz Zacha
Sławomir Janusz Zacha
Surgery of the thoracic and lumbar spine must employ monopolar electrical coagulation due to the necessity of bleeding control because alternative methods have too many limitations. The use of such electrocoagulation in cochlear implant (CI) users carries a high risk of damaging the assistive listening device. The objective of this paper is to present the management of 2 CI system users with advanced spinal curvature who required surgical treatment for scoliosis. A review of the literature was conducted on the use of medical procedures based on the conduction of electrical potentials within CI users. This paper presents 2 cases of surgery for spinal deformity in children who use CI. The precautions employed with regard to the utilization of monopolar coagulation are delineated. In neither case was damage to the CIs identified, despite the utilization of monopolar coagulation. A review of the literature revealed 415 documented instances of CIs being exposed to electrical current flow, of which 2 resulted in damage to the device. One case involved a patient who was defibrillated during cardiac arrest, while the other was related to dental pulp measurements on cadaveric teeth. Although monopolar electrocoagulation is considered a high-risk procedure for patients with CIs, this paper demonstrates that such procedures can be performed safely with appropriate precautions. It seems reasonable to conduct further experimental studies aimed at developing safe protocols to minimize the risk of damage to CI, ensuring that patients can undergo necessary medical procedures.