Introduction: Many studies have shown that monocyte human leukocyte antigen-DR (mHLA-DR) expression may be a good predictor for mortality in severe septic patients. On the contrary, other studies found mHLA-DR was not a useful prognostic marker in severe sepsis. Few studies have taken changes of mHLA-DR during treatment into consideration. The objective of this study was to estimate the prognostic value of changes of mHLA-DR to predict mortality in severe sepsis. Methods: In this prospective observational study, mHLA-DR was measured by flow cytometry in peripheral blood from 79 adult patients with severe sepsis. mHLA-DR levels were determined on day 0, 3, 7 after admission to the surgical intensive care unit (SICU) with a diagnosis of severe sepsis. ΔmHLA-DR3 and ΔmHLA-DR7 were defined as the changes in mHLA-DR value on day 3 and day 7 compared to that on day 0. Data were compared between 28-day survivors and non-survivors. Receiver operating characteristic (ROC) curves were plotted to measure the performance and discriminating threshold of ΔmHLA-DR3, ΔmHLA-DR7, ΔmHLA-DR7-3, mHLA-DR0, mHLA-DR3 and mHLA-DR7 in predicting mortality of severe sepsis. Results: ROC curve analysis showed that ΔmHLA-DR3 and ΔmHLA-DR7 were reliable indicators of mortality in severe sepsis. A ΔmHLA-DR3 value of 4.8% allowed discrimination between survivors and non-survivors with a sensitivity of 89.0% and a specificity of 93.7%; similarly, ΔmHLA-DR7 value of 9% allowed discrimination between survivors and non-survivors with a sensitivity of 85.7% and a specificity of 90.0%. Patients with ΔmHLA-DR3 ≤4.8% had higher mortality than those with ΔmHLA-DR3 > 4.8% (71.4% vs. 2.0%, OR 125.00, 95% CI 13.93 to 1121.67); patients with ΔmHLA-DR7 ≤9% had higher mortality than those with ΔmHLA-DR7 > 9% (52.9% vs. 2.0%, OR 54.00, 95% CI 5.99 to 486.08). The mean change of mHLA-DR significantly increased in the survivor group with the passage of time; from day 0 to day 3 and day 7, changes were 6.45 and 16.90 (P < 0.05), respectively. Conclusions: The change of mHLA-DR over time may be a reliable predictor for mortality in patients with severe sepsis.
Introduction: Severe sepsis is associated with a high mortality rate despite implementation of guideline recommendations. Adjunctive treatment may be efficient and require further investigation. In light of the crucial role of immunologic derangement in severe sepsis, thymosin alpha 1 (Tα1) is considered as a promising beneficial immunomodulatory drug. The trial is to evaluate whether Tα1 improves 28-day all-cause mortality rates and immunofunction in patients with severe sepsis. Methods: We performed a multicenter randomized controlled trial in six tertiary, teaching hospitals in China between May 12, 2008 and Dec 22, 2010. Eligible patients admitted in ICU with severe sepsis were randomly allocated by a central randomization center to the control group or Tα1 group (1:1 ratio). The primary outcome was death from any cause and was assessed 28 days after enrollment. Secondary outcomes included dynamic changes of Sequential Organ Failure Assessment (SOFA) and monocyte human leukocyte antigen-DR (mHLA-DR) on day 0, 3, 7 in both groups. All analyses were done on an intention-to-treat basis. Results: A total of 361 patients were allocated to either the control group (n = 180) or Tα1 (n = 181) group. The mortalities from any cause within 28 days in the Tα1 group and control group were 26.0% and 35.0% respectively with a marginal P value (nonstratified analysis, P = 0.062; log rank, P = 0.049); the relative risk of death in the Tα1 group as compared to the control group was 0.74 (95% CI 0.54 to 1.02). Greater improvement of mHLA-DR was observed in the Tα1 group on day 3 (mean difference in mHLA-DR changes between the two groups was 3.9%, 95% CI 0.2 to 7.6%, P = 0.037) and day 7 (mean difference in mHLA-DR changes between the two groups was 5.8%, 95% CI 1.0 to 10.5%, P = 0.017) than in the control group. No serious drug-related adverse event was recorded. Conclusions: The use of Tα1 therapy in combination with conventional medical therapies may be effective in improving clinical outcomes in a targeted population of severe sepsis. Trial registration: ClinicalTrials.gov NCT00711620.
8 September 2015 in Journal of Parenteral and Enteral Nutrition
Fluid overload is associated with increased morbidity and mortality in critically ill patients. However, researches rarely study the precise start or end point of fluid removal and no protocol was developed to control the fluid removal process. We hypothesized that individualized fluid removal with ultrasound-guided protocol could improve the efficacy and safety of fluid removal in post-resuscitated critically ill patients. A quasi-experimental, before and after trial was conducted to identify the benefits of ultrasound-guided fluid removal. Fluid removal was performed either following the doctor's experience in Control group, or abiding the ultrasound guided protocol in Ultrasound group. The study end points were the start time, end time, length of fluid removal, and the complications related to fluid removal. A total of 85 subjects were finally analyzed in this study. The fluid removal was started earlier, completed quicker and ended earlier (21.0 ± 14.6 h vs. 35.1 ± 26.5 h, 49.8 ± 32.6 vs. 93.0 ± 42.8 h, 69.0 ± 32.2 h vs. 126.4 ± 52.5 h, P < 0.05) in Ultrasound group than in Control. The subjects had more daily negative fluid balance and urine output (−990.4 ± 636.1 mL vs. −723.6 ± 549.5 mL, 2425.8 ± 886.7 mL vs. 1560.7 ± 1125.3 mL, P < 0.05) in Ultrasound group. The time of lung B-lines to reduce to zero was shorter and B-line at the end point was less (49.5 ± 36.6 h vs. 75.6 ± 58.8 h, 0[1] vs. 0[0], P < 0.05) in Ultrasound group. The length of intensive care unit stay in shock subgroup had a tendency to shorten (96.1 ± 61.5 h vs. 174.6 ± 132.0 h, P > 0.05) in Ultrasound group. We concluded that fluid removal with individualized ultrasound-guided protocol improves the efficacy and safety of dehydration in critically ill patients.
Background: An acute respiratory distress syndrome (ARDS) is still one of the major challenges in critically ill patients. This study aimed to investigate the effect of inhibiting c-Jun N-terminal kinase (JNK) on ARDS in a lipopolysaccharide (LPS)-induced ARDS rat model. Methods: Thirty-six rats were randomized into three groups: control, LPS, and LPS + JNK inhibitor. Rats were sacrificed 8 h after LPS treatment. The lung edema was observed by measuring the wet-to-dry weight (W/D) ratio of the lung. The severity of pulmonary inflammation was observed by measuring myeloperoxidase (MPO) activity of lung tissue. Moreover, the neutrophils in bronchoalveolar lavage fluid (BALF) were counted to observe the airway inflammation. In addition, lung collagen accumulation was quantified by Sircol Collagen Assay. At the same time, the pulmonary histologic examination was performed, and lung injury score was achieved in all three groups. Results: MPO activity in lung tissue was found increased in rats treated with LPS comparing with that in control (1.26 ± 0.15 U in LPS vs. 0.77 ± 0.27 U in control, P < 0.05). Inhibiting JNK attenuated LPS-induced MPO activity upregulation (0.52 ± 0.12 U in LPS + JNK inhibitor vs. 1.26 ± 0.15 U in LPS, P < 0.05). Neutrophils in BALF were also found to be increased with LPS treatment, and inhibiting JNK attenuated LPS-induced neutrophils increase in BALF (255.0 ± 164.4 in LPS vs. 53 (44.5-103) in control vs. 127.0 ± 44.3 in LPS + JNK inhibitor, P < 0.05). At the same time, the lung injury score showed a reduction in LPS + JNK inhibitor group comparing with that in LPS group (13.42 ± 4.82 vs. 7.00 ± 1.83, P = 0.001). However, the lung W/D ratio and the collagen in BALF did not show any differences between LPS and LPS + JNK inhibitor group. Conclusions: Inhibiting JNK alleviated LPS-induced acute lung inflammation and had no effects on pulmonary edema and fibrosis. JNK inhibitor might be a potential therapeutic medication in ARDS, in the context of reducing lung inflammatory.