Gianluca Cinotti

Gianluca Cinotti

Auto-generated profile, based on publicly available information

Gianluca Cinotti

Department of Anatomical, Histological, Forensic Medicine and Orthopedics Sciences, "Sapienza" University of Rome, Rome, Italy

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 1996 in Spine
Verified
Journal Article
Closed access
GCGianluca Cinotti
Gianluca Cinotti
TDThierry David
Thierry David
FPFranco Postacchini
Franco Postacchini
This study analyzed retrospectively 46 patients undergoing artificial disc replacement. To assess the clinical and radiographic outcomes of patients who had Charitè SB III disc prosthesis. Results of disc prosthesis have been reported only at very short-term follow-up periods; preoperative diagnosis and criteria used to evaluate the clinical outcomes were not reported. Forty-six patients who had had a disc prosthesis were evaluated clinically and radiographically at least 2 years after surgery. Preoperative diagnosis included disc degeneration in 22 patients and failed disc excision in 24 patients. Disc prosthesis was implanted at a single vertebral level in 36 patients and at two levels in 10 patients. Follow-up evaluation was performed after an average of 3.2 years (range, 2-5 years). Sixty-three percent of patients reported satisfactory results. The success rate was 69% in patients who underwent isolated disc replacement and 77% in those with no previous back surgeries. Seven patients who had unsatisfactory results underwent posterolateral fusion without removing the artificial disc. Two patients underwent removal of the prosthesis. No failure of the implants or loosenings or wear of the polyethylene core were found. Vertebral motion averaged 9 degrees at the operated levels and 16 degrees at the adjacent levels. A wrong surgical indication, rather than failure of the prosthesis, appears to be the main cause of unsatisfactory results of disc replacement at medium-term evaluations. Prospective and longer term studies are needed to establish whether disc prosthesis may offer advantages compared with spinal fusion.

1 January 1999 in Spine
Verified
Journal Article
Closed access
GCGianluca Cinotti
Gianluca Cinotti
SGStefano Gumina
Stefano Gumina
MRMaurizio Ripani
Maurizio Ripani
FPFranco Postacchini
Franco Postacchini
In part 1 of the study, the morphometry of thoracic pedicles and bony landmarks for pedicle screw placement were evaluated. In part 2, pedicle screws were inserted in fresh cadavers, using a different entry point in the left and right pedicles. To identify the safest entry point and screw orientation for pedicle screws in the thoracic spine. A few morphometric investigations have been performed on thoracic vertebrae, but the safest technique for screw insertion in thoracic pedicles has not been analyzed. Mean, range, and standard deviations of pedicle transverse diameter and pedicle orientation were measured in 99 dried thoracic vertebrae. We evaluated the position of the bottom of the superior facet and that of the superior border of the transverse process in relation to the center of the pedicle. The relation between the pedicle axis and the superior facet in the frontal plane was also assessed. In part 2 of the study, pedicle screws were inserted in fresh cadavers at the intersection between the superior border of the transverse process and the middle of the superior facet (entry point A) and between the former and the lateral two thirds of the facet (entry point B). The smallest transverse diameter was found at T6 (mean 4.3 mm) where pedicles measured less than 5 mm in 68% of the specimens. In the frontal plane, the pedicle axis intersected the middle of the superior facet in 15% of specimens, the lateral two-thirds in 62%, and the lateral border of the facet in 23%. Of the 126 screws inserted in fresh human cadavers, 15 (24%) of the screws inserted using entry point A and 10 (16%) of those inserted using entry point B violated the pedicle cortex (P > 0.05). Six (10%) of the screws inserted using entry point A compared with no screw inserted using entry point B penetrated the anterior vertebral cortex (P = 0.03). Pedicles between T4 and T8 may not be wide enough for screw fixation. An entry point for pedicle screws located at the intersection between the superior border of the transverse process and the lateral two thirds of the superior facet seems more likely to be in line with the pedicle axis than do other entry points. In the lower thoracic vertebrae this entry point, in combination with insertion of the screws more medially oriented than the pedicle axis, significantly reduces the risk of violating the anterior vertebral cortex.

1 November 2000 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
FPF. Postacchini
F. Postacchini
SGStefano Gumina
Stefano Gumina
GCG. Cinotti
G. Cinotti

1 February 2002 in Spine
Verified
Journal Article
Closed access
GCGianluca Cinotti
Gianluca Cinotti
PSPierfrancesco De Santis
Pierfrancesco De Santis
INItalo Nofroni
Italo Nofroni
FPFranco Postacchini
Franco Postacchini
In Study 1 the authors measured the vertical and sagittal dimensions of the intervertebral foramen in dried lumbar vertebrae. In Study 2 the dimensions of the intervertebral foramen were measured in fresh cadaveric spines in which the soft tissues forming the foraminal walls were preserved. To investigate whether disc narrowing, or other factors related to the morphometry of lumbar vertebrae, may predispose to foraminal stenosis. Predisposing factors to foraminal stenosis have been little investigated. Previous studies suggested that narrowing of the disc space might cause a reduction in the foraminal dimensions; however, it is not clear whether such a reduction is to such an extent as to compress the nerve root within the foramen. In Study 1 the vertical and sagittal dimensions of 160 intervertebral foramens were measured on dried white spines. Measurements were performed in the presence of a normal height of the disc space, obtained using a silicone rubber disc, and repeated in the same specimen after disc removal. Foraminal dimensions were then related to the sagittal diameter of the spinal canal and the pedicle length. In Study 2, the authors evaluated the dimensions of 50 intervertebral foramens of fresh cadaveric spines, in which the soft tissues forming the foraminal walls and the nerve root were preserved. In specimens showing normal or slightly decreased disc height, the foraminal dimensions were measured before and after disc excision. In Study 1 the reduction in the foraminal height after disc removal was, on average, 6.5 mm (P < 0.0001). In both Studies 1 and 2 the sagittal dimensions of the foramen were not significantly reduced after disc removal. No significant difference was found in Study 1 in the sagittal dimensions of the foramen between specimens showing normal or degenerated facet joints. In Study 2 a compression of the nerve root within the foramen was found in one specimen, showing a concomitant central stenosis at multiple levels. A significant correlation was found between the sagittal diameters of the foramen and the sagittal diameter of the spinal canal and the pedicle length. Narrowing of the disc space significantly reduces the vertical diameter of the foramen but has no significant effects on its sagittal dimensions. In contrast, the sagittal dimensions of the foramen are strictly related to the sagittal diameter of the spinal canal and the pedicle length. These results suggest that in patients with developmental or combined stenosis of the central spinal canal, a concomitant foraminal stenosis is likely to be present, or at least should be suspected.

1 September 1998 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Closed access
GCG. Cinotti
G. Cinotti
GRG. S. Roysam
G. S. Roysam
SES. M. Eisenstein
S. M. Eisenstein
FPF. Postacchini
F. Postacchini
We analysed prospectively 26 patients who had vision operations for ipsilateral recurrent radicular pain after a period of pain relief of more than six months following primary discectomy, They were assessed before the initial operation, between the two procedures and at a minimum of two years after reoperation. MRI was performed before primary discectomy and reoperation. Fifty consecutive patients who had a disc excision during the study period but did not have recurrent radicular pain, were analysed as a control group.ud ud Of the study group 42% related the onset of recurrent radicular pain to an isolated injury or a precipitating event, but none of the control group did so (p < 0.001). T2-weighted MRI performed before primary discectomy showed that patients in the study group had significantly more severe disc degeneration compared with the control group (p = 0.02). Intraoperative findings revealed recurrent disc herniation in 24 patients and bulging of the disc in two, one of whom also had lateral stenosis, Epidural scarring was found to be abundant, intraoperatively and on MRI, in eight and in nine patients, respectively.ud ud At the last follow-up, the clinical outcome was satisfactory in 85% of patients in the study group and in 88% of the control group (p > 0.05). Work or daily activities had been resumed at the same level as before the onset of symptoms by 81% of the patients in the study group and 84% of the control group. No correlation was found between the amount of epidural fibrosis, as seen intraoperatively and on MRI, and the result of surgery. The recurrence of radicular pain caused no significant changes in the psychological profile compared with the assessment before the primary discectomy

1 January 2005 in Spine
Verified
Journal Article
Closed access
GCGianluca Cinotti
Gianluca Cinotti
CRCarlo Della Rocca
Carlo Della Rocca
SRSalvatore Romeo
Salvatore Romeo
FVFranco Vittur
Franco Vittur
RTRenato Toffanin
Renato Toffanin
GTGuido Trasimeni
Guido Trasimeni
Graded endplate injuries were performed in porcine lumbar discs. The effects of such injuries were compared to control animals in which a sham operation was performed. To investigate the effects of endplate injuries on disc tissue. Studies have shown that injuries of vertebral endplates are frequently found at autopsy. However, little is known on the effects of acute injuries of vertebral endplates in vivo. Ten domestic pigs were included in the study group. Under general anesthesia, the lower three discs of the lumbar spine were exposed and randomly submitted to multiple endplate injuries, isolated endplate injury, and no treatment. A sham operation was performed in 5 pigs used as control group. Animals were killed 7 months after surgery and the harvested lumbar spine submitted to MRI investigations, histologic, and biochemical analysis. MRI showed that all but one discs treated with multiple endplate injuries were markedly degenerated while, of the discs treated with an isolated injury, one was markedly degenerated, five slightly degenerated and two were normal (P = 0.01). Histologic analysis showed severe changes in discs treated with multiple injuries. In those who had an isolated injury, changes were less severe and essentially limited to the posterior anulus or the inner anterior anulus. Biochemical analysis showed an inverse correlation between uronate content in the nucleus pulposus and severity of endplate injuries. Injuries of vertebral endplates in porcine discs were found to cause degenerative changes in the disc tissue on MRI, histologic, and biochemical investigations. The severity of such degenerative changes was related to the severity of endplate injuries. Injuries of vertebral endplate may be one of the pathomechanisms leading to early changes in the disc matrix and eventually to abnormal biomechanical behavior of the whole disc. The present animal model seems to be a suitable experimental model for disc degeneration.