Takefumi Ogawa

Takefumi Ogawa

Auto-generated profile, based on publicly available information

Takefumi Ogawa

The University of Tokyo, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2024 in IEEE Access
Verified
Journal Article
Open access
LZLingfeng Zhang
Lingfeng Zhang
ZWZunian Wan
Zunian Wan
YDYepeng Ding
Yepeng Ding
THTao Hu
Tao Hu
TOTakefumi Ogawa
Takefumi Ogawa
Hiroyuki SatoHiroyuki Sato
Hiroyuki Sato
Surface electromyography (sEMG), the electrical signals generated by muscle activity, plays an important role in prosthetics, orthotics, and human-computer interaction because of its non-invasive signal acquisition, real-time responsiveness, and ability to provide rich information for decoding complex movements. However, the complexity and nonlinear characteristics of sEMG signals present challenges in implementing sEMG-based tasks, such as hand gesture classification. Motivated by effectively addressing the challenges and extending the applicability of sEMG signals, we propose a nearest-centroid-based hand gesture classification framework using sEMG signals. We utilize the Dynamic Time Warping Barycenter Averaging (DBA) algorithm to generate centroids of sEMG signals and leverage Dynamic Time Warping (DTW) to measure signal discrepancies. Our pipeline features an effective data preprocessing approach and a heuristic, repeatable, optimal parameter search process. Additionally, our framework supports interpretability analysis using Shapley values. Through our extensive experiments, we demonstrate that our framework has achieved an average accuracy of 90.0% and a peak accuracy of 91.25% on a public dataset Mendeley data-sEMG, which outperforms the surveyed existing methods and establishes our framework as state-of-the-art on such dataset.

7 October 2024
Verified
Conference Paper
Open access
YTYota Takahara
Yota Takahara
ANArinobu Niijima
Arinobu Niijima
CPChanho Park
Chanho Park
TOTakefumi Ogawa
Takefumi Ogawa
This study aims to support eyes-free target acquisition in virtual reality by enhancing the user’s three-dimensional spatial awareness through sonification mapping pan, frequency, and amplitude to the x, y, and z axes, respectively. Our method provides two types of changing sounds. When multiple targets are sparsely arranged, the sound changes based on the distance between the user’s hand and the targets. When multiple targets are densely arranged, the sound changes based on the distance between the user’s hand and the central coordinate of the target group. Our two user studies, in which the targets were arranged sparsely and densely, respectively, showed that changing the sound exponentially and discretely minimized errors in eyes-free target acquisition.

13 April 2026
Verified
Conference Paper
Open access
ANArinobu Niijima
Arinobu Niijima
YPYixin Peng
Yixin Peng
CPChanho Park
Chanho Park
TOTakefumi Ogawa
Takefumi Ogawa
Electrical muscle stimulation (EMS) has been explored in HCI to support motor activities such as sports training and musical performance. Because contraction strength increases with stimulation intensity, EMS can modulate applied force and may support fine motor tasks such as brush-pressure control in calligraphy. However, conventional step-type EMS (StepEMS) applies the target intensity abruptly, often eliciting an involuntary onset twitch that distorts stroke trajectories. We propose RampEMS, which ramps pulse width to the target level over 1 s. This onset profile suppresses sudden movements while maintaining brush-pressure modulation. In a user study, we compared RampEMS and StepEMS in a calligraphy task and measured brush-pressure change and stroke deviation. Results indicate that RampEMS enables pressure modulation while significantly reducing stroke disturbance relative to StepEMS.

27 October 2024
Verified
Conference Paper
Open access
HMHana Mizukami
Hana Mizukami
ANArinobu Niijima
Arinobu Niijima
CPChanho Park
Chanho Park
TOTakefumi Ogawa
Takefumi Ogawa
In balance training, such as ballet, observing one’s posture in a mirror makes it easier to maintain balance. By using projectors, it is possible to show the user’s posture from different angles, magnify specific body parts, and display the Center of Pressure (COP) trajectory in real time. This gives the user more visual feedback information than a mirror can provide, helping to improve balance. However, the appropriate projection position and size to enhance the effect of such visual feedback remains unclear. This study focuses on relevé in ballet and examines the effects of different types and positions of visual feedback on balance improvement. We conducted a user study and calculated balance metrics from COP data obtained from a balance board. The results indicate that only visual feedback projected directly at eye level in front of the user during relevé contributes to balance improvement. In contrast, visual feedback projected above eye level to the right did not show a clear effect on balance improvement.

8 July 2025 in IEEE Access
Verified
Journal Article
Open access
HMHana Mizukami
Hana Mizukami
ANArinobu Niijima
Arinobu Niijima
CPChanho Park
Chanho Park
TOTakefumi Ogawa
Takefumi Ogawa
Providing real-time visual feedback during standing balance training has been shown to enhance balance ability. For example, displaying images of the trainee’s body or center-of-pressure (COP) trajectories while maintaining a standing posture facilitates the detection of postural sway, thereby improving balance. However, it remains unclear whether the spatial arrangement of such visual feedback influences the degree of balance improvement. Therefore, this study examined whether varying the display configuration of identical visual feedback affects balance enhancement. Specifically, we employed two fundamental ballet movements, “relevé” and “plié,” to investigate how different arrangements of body images and COP trajectories influence balance. Experimental results revealed that: (1) when a single visual feedback element was provided, placing it at eye level in front led to greater improvements in balance, and (2) when two visual feedback elements were presented simultaneously, arranging them side by side or overlapping yielded better balance outcomes. These findings highlight the significance of considering visual feedback arrangement to optimize balance enhancement.

29 July 2026
Verified
Book Chapter
Closed access
PDF file
MTMasaharu Takemura
Masaharu Takemura
ANArinobu Niijima
Arinobu Niijima
CPChanho Park
Chanho Park
TOTakefumi Ogawa
Takefumi Ogawa