Loreen Ruhm

Loreen Ruhm

Auto-generated profile, based on publicly available information

Loreen Ruhm

High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in NeuroImage
Verified
Journal Article
Open access
LRLoreen Ruhm
Loreen Ruhm
NANikolai Avdievich
Nikolai Avdievich
TZTheresia Ziegs
Theresia Ziegs
ANArmin M. Nagel
Armin M. Nagel
HFHenk M. De Feyter
Henk M. De Feyter
AHAnke Henning
Anke Henning
To present first highly spatially resolved deuterium metabolic imaging (DMI) measurements of the human brain acquired with a dedicated coil design and a fast chemical shift imaging (CSI) sequence at an ultrahigh field strength of B0 = 9.4 T. 2H metabolic measurements with a temporal resolution of 10 min enabled the investigation of the glucose metabolism in healthy human subjects. The study was performed with a double-tuned coil with 10 TxRx channels for 1H and 8TxRx/2Rx channels for 2H and an Ernst angle 3D CSI sequence with a nominal spatial resolution of 2.97 ml and a temporal resolution of 10 min. The metabolism of [6,6′-2H2]-labeled glucose due to the TCA cycle could be made visible in high resolution metabolite images of deuterated water, glucose and Glx over the entire human brain. X-nuclei MRSI as DMI can highly benefit from ultrahigh field strength enabling higher temporal and spatial resolutions.

5 September 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
EREulalia Serés Roig
Eulalia Serés Roig
HFHenk M. De Feyter
Henk M. De Feyter
TNTerence W. Nixon
Terence W. Nixon
LRLoreen Ruhm
Loreen Ruhm
ANAnton V. Nikulin
Anton V. Nikulin
RGRobin A. de Graaf
Robin A. de Graaf

29 June 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
NANikolai I. Avdievich
Nikolai I. Avdievich
ANAnton V. Nikulin
Anton V. Nikulin
LRLoreen Ruhm
Loreen Ruhm
AMArthur W. Magill
Arthur W. Magill
FGFelix Glang
Felix Glang
KSKlaus Scheffler
Klaus Scheffler
Purpose: To improve whole‐brain SNR at 7 Tesla, a novel 32‐element hybrid human head array coil was developed, constructed, and tested.Methods: Our general design strategy is based on 2 major ideas: Firstly, following suggestions of previous works based on the ultimate intrinsic SNR theory, we combined loops and dipoles for improvement of SNR near the head center. Secondly, we minimized the total number of array elements by using a hybrid combination of transceive (TxRx) and receive (Rx) elements. The new hybrid array consisted of 8 folded‐end TxRx‐dipole antennas and 3 rows of 24 Rx‐loops all placed in a single layer on the surface of a tight‐fit helmet.Results: The developed array significantly improved SNR in vivo both near the center (∼20%) and at the periphery (∼20% to 80%) in comparison to a common commercial array coil with 8 transmit (Tx) and 32 Rx‐elements. Whereas 24 loops alone delivered central SNR very similar to that of the commercial coil, the addition of complementary dipole structures provided further improvement. The new array also provided ∼15% higher Tx efficiency and better longitudinal coverage than that of the commercial array.Conclusion: The developed array coil demonstrated advantages in combining complementary TxRx and Rx resonant structures, that is, TxRx‐dipoles and Rx‐loops all placed in a single layer at the same distance to the head. This strategy improved both SNR and Tx‐performance, as well as simplified the total head coil design, making it more robust.

25 February 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
NANikolai I. Avdievich
Nikolai I. Avdievich
GSGeorgiy Solomakha
Georgiy Solomakha
LRLoreen Ruhm
Loreen Ruhm
AHAnke Henning
Anke Henning
KSKlaus Scheffler
Klaus Scheffler
Purpose: To develop an unshielded dipole transceiver array for human head imaging at 9.4 Tesla and to improve decoupling of adjacent dipole elements, a novel array design with modified passive dipole antennas was developed, evaluated, and tested.Methods: The new array consisted of 8 bent folded‐end dipole elements placed in a single row and surrounding the head. Adjacent elements of RF transceiver arrays are usually decoupled by introducing circuits electrically connected to elements. These methods are difficult to use for dipole arrays because of the distant location of the adjacent antennas. A recently developed decoupling technique using passive dipoles is simple and does not require any electrical connection. However, common parallel passive dipoles can produce destructive interference with the RF field of the array itself. To minimize this interference, we placed the passive dipoles perpendicularly to the active dipoles and positioned them at the ends of the array. We also evaluated the effect of different passive dipoles on the array transmit performance. Finally, we optimized the array transmit performance by varying the length of the dipole folded portion.Results: By rotating the passive dipoles 90º and moving them toward the ends of the array, we minimized the destructive interference to an acceptable level without compromising decoupling and the transmit efficiency.Conclusion: While keeping the benefits of the passive dipole decoupling method, the new modified dipoles produce substantially less destructive interference with the RF field of the array than the common design. The constructed transceiver array demonstrated good decoupling and whole‐brain coverage.

4 July 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
LRLoreen Ruhm
Loreen Ruhm
JDJohanna Dorst
Johanna Dorst
NANikolai Avdievitch
Nikolai Avdievitch
AWAndrew Martin Wright
Andrew Martin Wright
AHAnke Henning
Anke Henning
Purpose: To present 31P whole brain MRSI with a high spatial resolution to probe quantitative tissue analysis of 31P MRSI at an ultrahigh field strength of 9.4 Tesla.Methods: The study protocol included a 31P MRSI measurement with an effective resolution of 2.47 mL. For SNR optimization, the nuclear Overhauser enhancement at 9.4 Tesla was investigated. A sensitivity correction was achieved by applying a low rank approximation of the γ‐adenosine triphosphate signal. Group analysis and regression on individual volunteers were performed to investigate quantitative concentration differences between different tissue types.Results: Differences in gray and white matter tissue 31P concentrations could be investigated for 12 different 31P resonances. In addition, the first highly resolved quantitative MRSI images measured at B0 = 9.4 Tesla of 31P detectable metabolites with high SNR could be presented.Conclusion: With an ultrahigh field strength B0 = 9.4 Tesla, 31P MRSI moves further toward quantitative metabolic imaging, and subtle differences in concentrations between different tissue types can be detected.

11 January 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
JDJohanna Dorst
Johanna Dorst
LRLoreen Ruhm
Loreen Ruhm
NANikolai Avdievich
Nikolai Avdievich
WBWolfgang Bogner
Wolfgang Bogner
AHAnke Henning
Anke Henning
Purpose: In this study, different single‐voxel localization sequences were implemented and systematically compared for the first time for phosphorous MRS (31P‐MRS) in the human brain at 9.4 T.Methods: Two multishot sequences, image‐selected in vivo spectroscopy (ISIS) and a conventional slice‐selective excitation combined with localization by adiabatic selective refocusing (semiLASER) variant of the spin‐echo full intensity–acquired localized spectroscopy (SPECIAL‐semiLASER), and two single‐shot sequences, semiLASER and stimulated echo acquisition mode (STEAM), were implemented and optimized for 31P‐MRS in the human brain at 9.4 T. Pulses and coil setup were optimized, localization accuracy was tested in phantom experiments, and absolute SNR of the sequences was compared in vivo. The SNR per unit time (SNR/t) was derived and compared for all four sequences and verified experimentally for ISIS in two different voxel sizes (3 × 3 × 3 cm3, 5 × 5 × 5 cm3, 10‐minute measurement time). Metabolite signals obtained with ISIS were quantified. The possible spectral quality in vivo acquired in clinically feasible time (3:30 minutes, 3 × 3 × 3 cm3) was explored for two different coil setups.Results: All evaluated sequences performed with good localization accuracy in phantom experiments and provided well‐resolved spectra in vivo. However, ISIS has the lowest chemical shift displacement error, the best localization accuracy, the highest SNR/t for most metabolites, provides metabolite concentrations comparable to literature values, and is the only one of the sequences that allows for the detection of the whole 31P spectrum, including β–adenosine triphosphate, with the used setup. The SNR/t of STEAM is comparable to the SNR/t of ISIS. The semiLASER and SPECIAL‐semiLASER sequences provide good results for metabolites with long T2.Conclusion: At 9.4 T, high‐quality single‐voxel localized 31P‐MRS can be performed in the human brain with different localization methods, each with inherent characteristics suitable for different research issues.