Accurate quantification of noise exposure in military environments is challenging due to movement of listeners and noise sources, spectral and temporal noise characteristics, and varied use of hearing protection. This study evaluates a wearable recording device designed to measure on-body and in-ear noise exposure, specifically in an environment with significant impulse noise resulting from firearms. A commercial audio recorder was augmented to obtain simultaneous measurements inside the ear canal behind an integrated hearing protector, and near the outer ear. Validation measurements, conducted with an acoustic test fixture and shock tube, indicated high impulse peak insertion loss with a proper fit of the integrated hearing protector. The recording devices were worn by five subjects during a live-fire data collection at Marine Corps Base Quantico where Marines fired semi-automatic rifles. The field test demonstrated the successful measurement of high-level impulse waveforms with the on-body and in-ear recording system. Dual channels allowed for instantaneous fit estimates for the hearing protection component, and the device worked as intended in terms of hearing protection and noise dosimetry. Accurate measurements of noise exposure and hearing protector fit should improve the ability to model and assess the risks of noise-induced hearing loss.
17 December 2019 in International Journal of Audiology
Objective: In occupational hearing conservation programmes, age adjustments may be used to subtract expected age effects. Adjustments used in the U.S. came from a small dataset and overlooked important demographic factors, ages, and stimulus frequencies. The present study derived a set of population-based age adjustment tables and validated them using a database of exposed workers. Design: Cross-sectional population-based study and retrospective longitudinal cohort study for validation. Study sample: Data from the U.S. National Health and Nutrition Examination Survey (unweighted n = 9937) were used to produce these tables. Male firefighters and emergency medical service workers (76,195 audiograms) were used for validation. Results: Cross-sectional trends implied less change with age than assumed in current U.S. regulations. Different trends were observed among people identifying with non-Hispanic Black race/ethnicity. Four age adjustment tables (age range: 18–85) were developed (women or men; non-Hispanic Black or other race/ethnicity). Validation outcomes showed that the population-based tables matched median longitudinal changes in hearing sensitivity well. Conclusions: These population-based tables provide a suitable replacement for those implemented in current U.S. regulations. These tables address a broader range of worker ages, account for differences in hearing sensitivity across race/ethnicity categories, and have been validated for men using longitudinal data.
1 June 1995 in The Journal of the Acoustical Society of America
The dynamic aspects of the suppression of spontaneous otoacoustic emissions by external tones are evaluated. A Van der Pol oscillator driven by an external tone is used as an interpretive model for data on the pulsed suppression of spontaneous emissions obtained from six female subjects. Typical results for both the onset of, and recovery from suppression yield 1/r1 (where −r1 is the negative linear component of the damping function) in the range of 2–25 ms. In accordance with the predictions of the model, (a) the relaxation time for the onset of suppression increases with the amount of suppression induced by the external tone, (b) the values of r1 and the amplitudes of the unsuppressed emissions exhibit an inverse correlation, (c) the values inferred for r1 are not significantly dependent on the frequency of the pulsed suppressor tone, and (d) the inferred r1 values are not significantly dependent upon the amount of suppression.
1 August 2022 in The Journal of the Acoustical Society of America
National and international regulatory and consensus standards setting bodies have previously proposed derating hearing protector ratings to provide a better match between ratings determined in a laboratory and the real-world measurements of attenuation for workers. The National Institute for Occupational Safety and Health has proposed a derating scheme that depends upon the type of protector. This paper examines four real-world studies where personal attenuation ratings (PARs) were measured at least twice, before and after an intervention in earplug fitting techniques. Results from these studies indicate that individualized earplug fitting training dramatically improves a worker’s achieved PAR value. Additionally, derating schemes fail to accurately predict the majority of achieved PARs. Because hearing protector fit testing systems are now readily available for use in the workplace, personal attenuation ratings provide a better estimate of worker noise exposures and are able to identify those persons who need additional instruction in fitting hearing protection devices.
1 May 2009 in The Journal of the Acoustical Society of America
The National Institute for Occupational Safety and Health and the Environmental Protection Agency sponsored the completion of an interlaboratory study to compare two fitting protocols specified by ANSI S12.6-1997 (R2002) [(2002). American National Standard Methods for the Measuring Real-Ear Attenuation of Hearing Protectors, American National Standards Institute, New York]. Six hearing protection devices (two earmuffs, foam, premolded, custom-molded earplugs, and canal-caps) were tested in six laboratories using the experimenter-supervised, Method A, and (naïve) subject-fit, Method B, protocols with 24 subjects per laboratory. Within-subject, between-subject, and between-laboratory standard deviations were determined for individual frequencies and A-weighted attenuations. The differences for the within-subject standard deviations were not statistically significant between Methods A and B. Using between-subject standard deviations from Method A, 3–12 subjects would be required to identify 6-dB differences between attenuation distributions. Whereas using between-subject standard deviations from Method B, 5–19 subjects would be required to identify 6-dB differences in attenuation distributions of a product tested within the same laboratory. However, the between-laboratory standard deviations for Method B were −0.1to3.0dB less than the Method A results. These differences resulted in considerably more subjects being required to identify statistically significant differences between laboratories for Method A (12–132 subjects) than for Method B (9–28 subjects).
1 January 2023 in Proceedings of Meetings on Acoustics
Knowledge about the relationship between hearing protector attenuation and hearing protector fit has evolved over the decades, as has the accessibility to Knowledge about the relationship between hearing protector attenuation and hearing protector fit has evolved over the decades, as has the accessibility to