Qifeng Lu

Qifeng Lu

Auto-generated profile, based on publicly available information

Qifeng Lu

Shanghai EBIT Laboratory, Key Laboratory of Nuclear Physics and Ion-Beam Application (MOE), Institute of Modern Physics, Fudan University, Shanghai 200433, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2021 in Physical Review A
Verified
Journal Article
Closed access
PDF file
QLQ. Lu
Q. Lu
CYC. L. Yan
C. L. Yan
JMJ. Meng
J. Meng
GXG. Q. Xu
G. Q. Xu
YYY. Yang
Y. Yang
YZY. Zou
Y. Zou
To provide spectroscopic data for lowly charged tungsten ions relevant to fusion research, this work focuses on the W8+ ion. Six visible spectra lines from W8+ in the range of 420–660 nm are observed with a compact electron-beam ion trap in Shanghai. Furthermore, transition energies are calculated for the 30 lowest levels of the 4f145s25p4, 4f135s25p5, and 4f125s25p6 configurations of W8+ by using the flexible atomic code (fac) and grasp package. Reasonably good agreement is found between our two independent atomic-structure calculations. The resulting atomic parameters are adopted to simulate the spectra based on the collisional-radiative model implemented in the fac code. This assists us with identification of six strong magnetic-dipole transitions in the 4f135s25p5 and 4f125s25p6 configurations from our experiments.

27 September 2022 in The Astrophysical Journal
Verified
Journal Article
Open access
GXGuoqin Xu
Guoqin Xu
CYChenglong Yan
Chenglong Yan
QLQifeng Lu
Qifeng Lu
ZTZhi-Ming Tang
Zhi-Ming Tang
YYYang Yang
Yang Yang
YZYaming Zou
Yaming Zou
The magnetic field is extremely important for understanding the properties of the solar corona. However, there are still difficulties in the direct measurement of the coronal magnetic field. The magnetic-field-induced transition (MIT) in Fe x, appearing in coronal spectra, was discovered to have prospective applications in coronal magnetic field measurements. In this work, we obtained the extreme ultraviolet spectra of Fe x in the wavelength range of 174–267 Å in the Shanghai High-temperature Superconducting Electron Beam Ion Trap, and examined the effect of MIT in Fe x by measuring the line ratios between 257.262 Å and the reference line of 226.31 Å (257/226) at different magnetic field strengths for the first time. The electron density that may affect the 257/226 value was also obtained experimentally and verified by comparing the density-sensitive line ratio (175.266 Å/174.534 Å) measurements with the theoretical predictions, and there was good agreement between them. The energy separation between the two levels of 3s23p43d 4 D 5/2 and 3s23p43d 4 D 7/2, one of the most critical parameters for determining the MIT rate, was obtained by analyzing the simulated line ratios of 257/226 with the experimental values at the given electron densities and magnetic fields. Possible reasons that may have led to the difference between the obtained energy splitting and the recommended value in previous works are discussed. Magnetic field response curves for the 257/226 value were calculated and compared to the experimental results, which is necessary for future MIT diagnostics.

21 October 2020 in Physical Review A
Verified
Journal Article
Closed access
PDF file
QLQ. Lu
Q. Lu
CYC. L. Yan
C. L. Yan
GXG. Q. Xu
G. Q. Xu
NFN. Fu
N. Fu
YYY. Yang
Y. Yang
RHR. Hutton
R. Hutton
Using electron-beam ion traps (EBITs), we have made direct measurements for the fine-structure splitting 2p5 of S viii and Cl ix, which are important to the test of ab initio theory in F-like ions. Their wavelength are redetermined in the laboratory with an accuracy of 23 ppm, i.e., 10085.40±0.23cm−1 for S viii, where the early value observed in the solar spectrum is questionable, and 13643.39±0.32cm−1 for Cl ix, where only indirect measurements had been performed. High-precision calculations, including ab initio treatment of QED effects, are accomplished for 10≤Z≤18 and compared with the experimental results. Good agreement is found between our experimental and theoretical values of the fine-structure energy among these ions except for Al v, which calls for further investigations. Besides, we have succeeded in pushing EBIT operation towards the infrared spectral region relevant to astrophysics.

1 March 2021 in Journal of Quantitative Spectroscopy and Radiative Transfer
Verified
Journal Article
Closed access
QLQ. Lu
Q. Lu
CYC.L. Yan
C.L. Yan
NFN. Fu
N. Fu
YYY. Yang
Y. Yang
CCC.Y. Chen
C.Y. Chen
YZY. Zou
Y. Zou

26 September 2022 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
ZLzhu liuhua
zhu liuhua
YBYansong Bao
Yansong Bao
QLQifeng Lu
Qifeng Lu
SFShuiyong Fan
Shuiyong Fan
George PetropoulosGeorge Petropoulos
George Petropoulos
XLXinglu Li
Xinglu Li
Ground-based microwave radiometers (MWRs) are used to provide temperature and relative humidity (RH) profiles mainly at boundary layer with temporal resolution of 1–2 min. However, accuracy of MWR away from radiosondes locations is not satisfactory. In this study, we proposed temperature and RH retrieval models based on fifth-generation reanalysis (ERA5) data that allow the replacement of the original model based on adjacent radiosondes. This study focuses on how to resolve the unrepresentativeness of ERA5 data. A quality control (QC) scheme was proposed after analyzing the characteristics of ERA5 data, which was confirmed to have positive effects for retrieval results. Three retrieval models for MWR at Nanjiao site based on ERA5 data (ERA5-retrieval), co-located radiosondes (RS-retrieval 1), and adjacent radiosondes (RS-retrieval 2) were developed. An extensive validation that was carried out showed ERA5-retrieval improved the accuracy of temperature and RH profiles compared with the original method RS-retrieval 2 and LV2 product from MWR. Furthermore, the proposed retrieval method was applied to six MWR sites without radiosondes co-located in Beijing and illustrated the feasibility and accuracy of the proposed method. In overall, the retrieval approach proposed based on ERA5 data and data QC can improve both temperature and RH accuracy for MWR sites away from radiosondes.

1 January 2021 in Applied Ecology and Environmental Research
Verified
Journal Article
Open access
WXW.D. Xu
W.D. Xu
GLG. Li
G. Li
JLJ. Li
J. Li
QLQ. Lu
Q. Lu