Tiago Neves

Tiago Neves

Auto-generated profile, based on publicly available information

Tiago Neves

FiberSight, Instituto Pedro Nunes, Rua Pedro Nunes, 3030-199 Coimbra, Portugal

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GBGaia Maria Berruti
Gaia Maria Berruti
PVPatrizio Vaiano
Patrizio Vaiano
GQGiuseppe Quero
Giuseppe Quero
TNTiago Filipe Pimentel Das Neves
Tiago Filipe Pimentel Das Neves
ABAlessandra Boniello
Alessandra Boniello
ACAndrea Cusano
Andrea Cusano
In this contribution, a complete dissertation concerning the behavior of a Long Period Grating (LPG) inscribed in a B-Ge co-doped optical fiber by means of an excimer laser and exposed to proton irradiation during a recent extensive campaign performed at the European Organization for Nuclear Research (CERN) with a fluence of 4.4·1015 p∙cm−2 is provided. The experimental results have been thus combined for the first time to the best of our knowledge with numerical simulations in order to estimate the variations of the major parameters affecting the grating response during the ultra-high dose proton exposure. From the correlation between experimental and numerical analysis, the irradiation exposure was found to induce a maximal variation of the core effective refractive index of ~1.61·10−4, responsible of a resonance wavelength red shift of ~44 nm in correspondence of the highest absorbed radiation dose of 1.16 MGy. At the same time, a relevant decrease close to ~0.93·10−4 in the refractive index modulation pertaining to the grating was estimated, leading to a reduction of the resonant dip visibility of ~12 dB. The effect of the proton beam on the spectral response of the LPG device and on the optical fiber parameters was assessed during the relaxation phases, showing a partial recovery only of the wavelength shift without any relevant change in the dip visibility revealing thus a partial recovery only in the refractive index of the core while the reduction of the refractive index modulation observed during the irradiation remained unchanged.

11 February 2022 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
RMRegina Magalhães
Regina Magalhães
TNTiago Neves
Tiago Neves
LSLorenzo Scherino
Lorenzo Scherino
SMSonia Martin-Lopez
Sonia Martin-Lopez
HMHugo F. Martins
Hugo F. Martins
Distributed Acoustic Sensing (DAS) based on coherent reflectometry with chirped pulses (CP-ϕOTDR) is a recent, yet widely recognized technique in providing spatially-resolved distributed measurements of certain physical quantities over the length of an optical fiber. Any given perturbation along the cable can be retrieved as a local temporal shift of the backscattered optical power trace, and recovered using sequential trace-to-trace correlations. However, as a technique that relies on a General Cross-correlation (GCC) estimation function, it displays a non-zero probability of obtaining anomalous estimations, which can fundamentally limit the long-term performance. Furthermore, some demonstrated strategies proposed to mitigate this effect can directly lead to the emergence of cumulative errors, which become as critical as the measurement time increases. Here, we analyze the errors affecting the long-term stability in CP-ϕOTDR systems, and we propose several strategies and processing methods to mitigate their effect. We demonstrate a ∼3 mK error after a one-month continuous temperature experiment performed to a SMF, reaching unprecedented temperature stability in CP-ϕOTDR systems with important implications in emerging fields such as DAS seismology or oceanography.

3 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
LMLiliana Martelo
Liliana Martelo
TNTiago F. Pimentel Das Neves
Tiago F. Pimentel Das Neves
JFJoão Figueiredo
João Figueiredo
Lino MarquesLino Marques
Lino Marques
AFAlexander Fedorov
Alexander Fedorov
HBHugh Burrows
Hugh Burrows
Conjugated polymers (CPs) have proved to be promising chemosensory materials for detecting nitroaromatic explosives vapors, as they quickly convert a chemical interaction into an easily-measured high-sensitivity optical output. The nitroaromatic analytes are strongly electron-deficient, whereas the conjugated polymer sensing materials are electron-rich. As a result, the photoexcitation of the CP is followed by electron transfer to the nitroaromatic analyte, resulting in a quenching of the light-emission from the conjugated polymer. The best CP in our studies was found to be poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-bithiophene] (F8T2). It is photostable, has a good absorption between 400 and 450 nm, and a strong and structured fluorescence around 550 nm. Our studies indicate up to 96% quenching of light-emission, accompanied by a marked decrease in the fluorescence lifetime, upon exposure of the films of F8T2 in ethyl cellulose to nitrobenzene (NB) and 1,3-dinitrobenzene (DNB) vapors at room temperature. The effects of the polymeric matrix, plasticizer, and temperature have been studied, and the morphology of films determined by scanning electron microscopy (SEM) and confocal fluorescence microscopy. We have used ink jet printing to produce sensor films containing both sensor element and a fluorescence reference. In addition, a high dynamic range, intensity-based fluorometer, using a laser diode and a filtered photodiode was developed for use with this system.

17 May 2023 in Applied Optics
Verified
Journal Article
Closed access
TNTiago F. P. Neves
Tiago F. P. Neves
LSLorenzo Scherino
Lorenzo Scherino
RBRémy Bernard
Rémy Bernard
MBMonika Bouet
Monika Bouet
APAymeric Pastre
Aymeric Pastre
LTLuc Thévenaz
Luc Thévenaz
Humidity is a critical environmental factor in various applications, and its temperature dependence must be considered when developing thermo-hygrometer fiber sensors. The optical fibers that constitute the sensor must have a temperature reference, which should be resistant to humidity to avoid cross-sensitivities. This paper presents two innovative optical fibers insensitive to humidity over temperatures ranging from −20∘C to 55°C. To the best of our knowledge, the novel standard size optical fibers coated with acrylate and silicone are tested under controlled conditions using an optical time-domain reflectometer sensor based on Rayleigh scattering. The sensor achieves meter-range resolution over kilometers of length with a response time of few minutes.

28 August 2019
Verified
Conference Paper
Closed access
PDF file
TNTiago F. P. Neves
Tiago F. P. Neves
LZLi Zhang
Li Zhang
FYFan Yang
Fan Yang
KTKenny H. Tow
Kenny H. Tow
PPPaolo Petagna
Paolo Petagna
LTLuc Thévenaz
Luc Thévenaz
Fibre optics sensors have been identified as very good candidates for environmental monitoring inside the silicon detectors operated at CERN’s Large Hadron Collider. In this study, we present the results from the first highly sensitive relative humidity distributed sensor with kilometres sensing range. The setup is a 70 cm spatial resolution phase-sensitive Optical Time Domain Reflectometry (OTDR) and is able to monitor fibre lengths up to 10 km. The coating effect is also evaluated, analysing different coating thicknesses, number of coating layers, different manufacturing and different materials. Relative humidity tests were performed at two different temperatures (25°C and 42°C). Polyimide coated fibres show in general a higher humidity sensitivity then a standard acrylate coated fibre, while acrylate fibres offer the fastest response and settling time. The system is able to resolve 0.1% RH and all tested fibres proved to be good candidates to be employed in a distributed relative humidity sensor. If the requirements are a fast time response and short settling time at room temperature, the standard acrylate coated fibres are the best candidates. However, if the requirements are high sensitivity and measurement stability at different temperatures, the polyimide-coated fibres offer advantages on several aspects.

1 January 2018
Verified
Conference Paper
Closed access
PDF file
GBGaia Maria Berruti
Gaia Maria Berruti
TNTiago Filipe Pimentel Das Neves
Tiago Filipe Pimentel Das Neves
MCMarco Consales
Marco Consales
Patrizio VaianoPatrizio Vaiano
Patrizio Vaiano
GQGiuseppe Quero
Giuseppe Quero
ACAndrea Cusano
Andrea Cusano
In this contribution, the response of a Long Period Grating (LPG) inscribed in a B/Ge co-doped optical fiber exposed to proton irradiation is presented for the first time to the best of our knowledge. The experiment was performed in the proton irradiation facility at the European Organization for Nuclear Research (CERN) and lasted 146 hours. A proton fluence of ~ 4.4×1015 p/cm2 was applied during the experiment, corresponding to a total absorbed dose by the sample of ~ 1.16 MGy. From the on-line measurements, we evaluated a maximum radiation induced shift of ~ 44 nm and no saturation was observed at the maximal accumulated dose. A post-irradiation recovery shift of ~ 7 nm was measured after 7.5 days. Collected off- line results demonstrated that the LPG temperature sensitivity is not significantly affected by irradiation.