28 January 2020 in Scientific Reports
In this contribution, a complete dissertation concerning the behavior of a Long Period Grating (LPG) inscribed in a B-Ge co-doped optical fiber by means of an excimer laser and exposed to proton irradiation during a recent extensive campaign performed at the European Organization for Nuclear Research (CERN) with a fluence of 4.4·1015 p∙cm−2 is provided. The experimental results have been thus combined for the first time to the best of our knowledge with numerical simulations in order to estimate the variations of the major parameters affecting the grating response during the ultra-high dose proton exposure. From the correlation between experimental and numerical analysis, the irradiation exposure was found to induce a maximal variation of the core effective refractive index of ~1.61·10−4, responsible of a resonance wavelength red shift of ~44 nm in correspondence of the highest absorbed radiation dose of 1.16 MGy. At the same time, a relevant decrease close to ~0.93·10−4 in the refractive index modulation pertaining to the grating was estimated, leading to a reduction of the resonant dip visibility of ~12 dB. The effect of the proton beam on the spectral response of the LPG device and on the optical fiber parameters was assessed during the relaxation phases, showing a partial recovery only of the wavelength shift without any relevant change in the dip visibility revealing thus a partial recovery only in the refractive index of the core while the reduction of the refractive index modulation observed during the irradiation remained unchanged.
11 February 2022 in Journal of Lightwave Technology
Distributed Acoustic Sensing (DAS) based on coherent reflectometry with chirped pulses (CP-ϕOTDR) is a recent, yet widely recognized technique in providing spatially-resolved distributed measurements of certain physical quantities over the length of an optical fiber. Any given perturbation along the cable can be retrieved as a local temporal shift of the backscattered optical power trace, and recovered using sequential trace-to-trace correlations. However, as a technique that relies on a General Cross-correlation (GCC) estimation function, it displays a non-zero probability of obtaining anomalous estimations, which can fundamentally limit the long-term performance. Furthermore, some demonstrated strategies proposed to mitigate this effect can directly lead to the emergence of cumulative errors, which become as critical as the measurement time increases. Here, we analyze the errors affecting the long-term stability in CP-ϕOTDR systems, and we propose several strategies and processing methods to mitigate their effect. We demonstrate a ∼3 mK error after a one-month continuous temperature experiment performed to a SMF, reaching unprecedented temperature stability in CP-ϕOTDR systems with important implications in emerging fields such as DAS seismology or oceanography.
17 May 2023 in Applied Optics
Humidity is a critical environmental factor in various applications, and its temperature dependence must be considered when developing thermo-hygrometer fiber sensors. The optical fibers that constitute the sensor must have a temperature reference, which should be resistant to humidity to avoid cross-sensitivities. This paper presents two innovative optical fibers insensitive to humidity over temperatures ranging from −20∘C to 55°C. To the best of our knowledge, the novel standard size optical fibers coated with acrylate and silicone are tested under controlled conditions using an optical time-domain reflectometer sensor based on Rayleigh scattering. The sensor achieves meter-range resolution over kilometers of length with a response time of few minutes.