Dushan Darshana Walawege

Dushan Darshana Walawege

Auto-generated profile, based on publicly available information

Dushan Darshana Walawege

Groundwater (Investigation) Section, National Water Supply and Drainage Board, Ratmalana 10390, Sri Lanka

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2024 in Water Practice & Technology
Verified
Journal Article
Open access
PDF file
DWDushan Darshana Walawege
Dushan Darshana Walawege
Buddhika WickramasinghaBuddhika Wickramasingha
Buddhika Wickramasingha
RSRanepura Dewage Charuka Sandaruwan
Ranepura Dewage Charuka Sandaruwan
SUSamitha Udayanga
Samitha Udayanga
UPUdari Perera
Udari Perera
BBB.K.A. Bellanthudawa
B.K.A. Bellanthudawa
Chronic Kidney Disease of Unknown Etiology (CKDu) affects rural Sri Lankan agricultural populations, with poor-quality ground and surface water suspected as the root cause. Hence, we conducted this study to explore the effectiveness of Electrodialysis Reversal (EDR) technology in treating water quality issues related to CKDu in dry zone of Sri Lanka. The EDR plant in Kahatagasdigiliya, Anuradhapura district, managed by the National Water Supply and Drainage Board (NWS&DB) was selected. We measured both physical (colour, turbidity, pH) and chemical (electrical conductivity, total dissolved solids, chloride, alkalinity, hardness, nitrate, nitrite, sulfate, fluoride, total phosphate, iron, manganese) parameters of the EDR process. The parameters of the permeate stage of the EDR plant were validated by comparison with data from SLS 614:2013, and removal efficiencies were assessed. The results revealed that all parameters consistently fell within the permissible limits in the permeate stage of the EDR plant. Turbidity (62.65%), sulfate and manganese (50%), colour (47.37%), fluoride (44.19%), and hardness (35.71%) showed high removal efficiencies in the EDR process. The study demonstrated the effectiveness of EDR technology in addressing water quality challenges, validating its potential for groundwater treatment and this contributes to the improvement of groundwater quality in CKDu-prevalent areas.

18 December 2023 in Engineer: Journal of the Institution of Engineers, Sri Lanka
Verified
Journal Article
Open access
PDF file
DWDushan D. Walawege
Dushan D. Walawege
Manikins that simulate cardiopulmonary resuscitation (CPR) are used to teach personnel how to execute it. Modern cardiac resuscitation manikins are still low-fidelity designs in terms of anatomy and physiology. Designing a manikin with a cardiac and respiratory system, as well as integrated flow sensors to track cardiac output and air displacement in response to cardiopulmonary resuscitation, was the main goal of this research. A polyoxy-methylene rib cage joined to a vertebral column from an anatomical female model was used to create this manikin in line with anatomical proportions. The respiratory system was made up of a polyvinyl chloride bronchus, a latex trachea, and silicon-coated memory foam that mimicked lungs. The pulmonary and aortic arteries were represented by two sets of latex tubing, while the ventricles and aggregated abdominal volumes were represented by latex balloons, respectively. These components made up the cardiovascular system. These balloons were inserted into polyether foam and filled with blood from a life/form simulation. Flow sensors were installed in the respiratory and cardiovascular systems to collect data in reaction to chest compressions. On this manikin, three non-medical individuals applied chest compressions that produced data proportional to force-displacement while the flow sensors supplied feedback. The force-displacement experiments performed on this manikin demonstrate an advantageous nonlinear behavior that mimics the chest compressions used during cardiopulmonary resuscitation in humans. A considerable amount of information on the internal effects of cardiopulmonary resuscitation is also provided by the flow sensors. To sum up, scientifically developed and anatomically accurate designs of cardiopulmonary resuscitation manikins that incorporate flow sensors can enhance physiological fidelity and offer helpful feedback data.