Himadri Lala

Himadri Lala

Auto-generated profile, based on publicly available information

Himadri Lala

School of Electrical Engineering, Vellore Institute of Technology, Vellore, India

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2023 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
MTM. Thirunavukkarasu
M. Thirunavukkarasu
Yashwant SawleYashwant Sawle
Yashwant Sawle
HLHimadri Lala
Himadri Lala

28 February 2020 in IEEE Systems Journal
Verified
Journal Article
Closed access
HLHimadri Lala
Himadri Lala
SKSubrata Karmakar
Subrata Karmakar
The effect of high impedance faults (HIFs) in a distribution system has an effect on the system stability and reliability. The high impedance arc fault (HIAF) even poses a significant threat to the living being as it involves arcing. The HIAF have the same V–I characteristics as HIF, but the enormous amount of heat generation is a significant concern to differentiate between them. Moreover, there are different types of arc which may occur depending on the arcing conditions and arcing surfaces. In this article, arc due to leaning-tree on a medium-voltage distribution line and the arc in between sphere-gaps are considered as the main event of analysis. An empirical mode decomposition (EMD)-based approach is used along with artificial neural network (ANN) for the analysis of real-time arc signals. The result obtained by the application of EMD and ANN on arc voltage signals successfully detects and classifies the arcing events by their predominant harmonic signatures. A comparison of EMD results with other techniques is presented. Arc in soil and wet-sand is also considered for the validation of the proposed algorithm for other arcing surfaces. Support vector machine and Kth nearest neighbor machine learning techniques are also utilized for classification.

1 April 2024 in IEEE Access
Verified
Journal Article
Open access
SPSekar Palanisamy
Sekar Palanisamy
HLHimadri Lala
Himadri Lala
The primary barrier to the extensive implementation of electric vehicles (EVs) is the lack of necessary and adequate charging infrastructure within a particular area. Moreover, sourcing the energy needed for EVs from the grid that heavily relies on fossil fuels diminishes the environmental advantages of EVs and, further increases strain on grid system in electricity-deficient regions. Therefore, this study designs and simulates six different standalone hybrid renewable energy systems utilizing solar, wind, and biomass sources and a grid-tied system for a selected location of Singaperumal Kovil, Chennai, India. One unique aspect of this research is the use of a single station for charging electric vehicles and hydrogen refueling. These systems are designed to fulfil the energy requirements of 48 battery-electric vehicles and 17 hydrogen vehicles, Using HOMER Pro software, combining a bio-gas generator, wind turbine, and photovoltaic system. The renewable energy sources are identified as the most practical and reliable among the various cases for that location, in terms of technical, economic, and environmental feasibility. Among six different standalone scenarios and a grid-tied system, the biogas generator, wind, and PV configuration model is more cost effective than other configurations. The proposed system generates 2,009,492 kWh/yr of electricity and 30,199 kg/yr of Hydrogen. The reported values for the NPC, LCOE, LCOH, and payback period were $3.46 million, $0.493/kWh, $8.86/kg, and about 3.08 years, in that order. HOMER determines the breakeven grid extension distance as 129.93km.After considering the effective rate after digestate, the NPC, LCOE, and LCOH costs are reduced to $2.90 million, $0.412/kWh, and $7.47/kg, respectively.

19 May 2023 in Alexandria Engineering Journal
Verified
Journal Article
Open access
MTM. Thirunavukkarasu
M. Thirunavukkarasu
HLHimadri Lala
Himadri Lala
Yashwant SawleYashwant Sawle
Yashwant Sawle

31 August 2023 in Renewable Energy
Verified
Journal Article
Closed access
MTM. Thirunavukkarasu
M. Thirunavukkarasu
HLHimadri Lala
Himadri Lala
Yashwant SawleYashwant Sawle
Yashwant Sawle

4 October 2024 in IEEE Access
Verified
Journal Article
Open access
PSPriteesha Sarangi
Priteesha Sarangi
PMPrabhujit Mohapatra
Prabhujit Mohapatra
HLHimadri Lala
Himadri Lala
Renewable energy systems provide a dependable, environment-friendly, and cost-effective alternative for producing electricity in remote regions. The growing use of meta-heuristic algorithms is attributed to their ability to provide rapid, accurate, and optimal results for intricate optimization challenges. Therefore, in this work, an Evolved Opposition-based Mountain Gazelle Optimizer (EOBMGO) algorithm is explored to achieve the optimal design for the combination of off-gird hybrid renewable energy systems (HRES) that incorporate solar photovoltaic (PV) modules, wind turbines, and battery systems. The primary objective of the optimization process is to minimize the total net annual cost while maintaining an acceptable loss of power supply probability (LPSP), considering levelized energy costs and the generation of excess power. The designed EOBMGO technique has been evaluated for three distinct LPSP values (0%, 0.5%, and 1%), with each value tested across 25 independent runs and 50 iterations. The designed algorithm is then assessed against several established optimizers, including Grey Wolf Optimizer (GWO), Artificial Rabbit Optimization (ARO), Brown-bear Optimization Algorithm (BOA), and White Shark Optimizer (WSO). Statistical analysis has been performed to highlight the superiority of the EOBMGO algorithm over others, which included an evaluation of mean, standard deviation, variance, and crest values. The simulation outcomes revealed that the EOBMGO technique achieved a lower oscillation rate, a low standard deviation, and superior balancing of exploitation and exploration capabilities. Further, EOBMGO is found robust in the sensitivity analysis with variation in capital cost of the major components. These outcomes will provide researchers with a valuable reference for choosing the optimal technique for sizing problems.