1 April 2000 in The Astronomical Journal
The ROTSE-I experiment has generated CCD photometry for the entire Northern sky in two epochs nightly since March 1998. These sky patrol data are a powerful resource for studies of astrophysical transients. As a demonstration project, we present first results of a search for periodic variable stars derived from ROTSE-I observations. Variable identification, period determination, and type classification are conducted via automatic algorithms. In a set of nine ROTSE-I sky patrol fields covering about 2000 square degrees we identify 1781 periodic variable stars with mean magnitudes between m_v=10.0 and m_v=15.5. About 90% of these objects are newly identified as variable. Examples of many familiar types are presented. All classifications for this study have been manually confirmed. The selection criteria for this analysis have been conservatively defined, and are known to be biased against some variable classes. This preliminary study includes only 5.6% of the total ROTSE-I sky coverage, suggesting that the full ROTSE-I variable catalog will include more than 32,000 periodic variable stars.Comment: Accepted for publication in AJ 4/00. LaTeX manuscript. (28 pages, 11 postscript figures and 1 gif
1 January 1991 in Journal of Applied Social Psychology
28 June 2024 in Journal of Structural Biology
Developments in direct electron detector technology have played a pivotal role in enabling high-resolution structural studies by cryo-EM at 200 and 300 keV. Yet, theory and recent experiments indicate advantages to imaging at 100 keV, energies for which the current detectors have not been optimized. In this study, we evaluated the Gatan Alpine detector, designed for operation at 100 and 200 keV. Compared to the Gatan K3, Alpine demonstrated a significant DQE improvement at these energies, specifically a ∼ 4-fold improvement at Nyquist at 100 keV. In single-particle cryo-EM experiments, Alpine datasets yielded better than 2 Å resolution reconstructions of apoferritin at 120 and 200 keV on a ThermoFisher Scientific (TFS) Glacios microscope fitted with a non-standard SP-Twin lens. We also achieved a ∼ 3.2 Å resolution reconstruction of a 115 kDa asymmetric protein complex, proving Alpine's effectiveness with complex biological samples. In-depth analysis revealed that Alpine reconstructions are comparable to K3 reconstructions at 200 keV, and remarkably, reconstruction from Alpine at 120 keV on a TFS Glacios surpassed all but the 300 keV data from a TFS Titan Krios with GIF/K3. Additionally, we show Alpine's capability for high-resolution data acquisition and screening on lower-end systems by obtaining ∼ 3 Å resolution reconstructions of apoferritin and aldolase at 100 keV and detailed 2D averages of a 55 kDa sample using a side-entry cryo holder. Overall, we show that Gatan Alpine performs well with the standard 200 keV imaging systems and may potentially capture the benefits of lower accelerating voltages, bringing smaller sized particles within the scope of cryo-EM.
6 May 2014 in Optics Express
A high-finesse broadband optical cavity has been developed for use in the ultraviolet and visible region using Brewster-angle calcium fluoride (CaF2) prism retroreflectors. Prior to prism construction, optical loss measurements of CaF2 windows were performed using cavity ring-down spectroscopy at 250 nm. Total optical loss showed high spatial correlation with crystal birefringence, which was partially mitigated by orienting the crystal axis with the laser beam. Prism reflectivity was measured using cavity ring-down spectroscopy and found to be 99.77% at 250 nm and 99.96% at 500 nm, allowing for relatively high-finesse operation over hundreds of nm bandwidth with a single cavity.
1 June 2012 in Publications of the Astronomical Society of the Pacific
The dispersed fixed-delay Intereferometer (DFDI) method is attractive for its low cost, compact size, and multiobject capability in precision radial-velocity (RV) measurements. The phase shift of fringes of stellar absorption lines is measured and then converted to an RV shift via an important parameter, phase-to-velocity scale (PV scale), determined by the group delay (GD) of a fixed-delay interferometer. Two methods of GD measurement using a DFDI Doppler instrument are presented in this article: (1) GD measurement using white-light combs generated by the fixed-delay interferometer and (2) GD calibration using an RV reference star. These two methods provide adequate precision of GD measurement and calibration, given the current RV precision achieved by a DFDI Doppler instrument. They can potentially be used to measure GD of an fixed-delay interferometer for submeter-precision Doppler measurement with a DFDI instrument. Advantages and limitations of each method are discussed in detail. The two methods can serve as standard procedures of PV-scale calibration for DFDI instruments and cross-checks for each other.