Naresh P. Patel

Naresh P. Patel

Auto-generated profile, based on publicly available information

Naresh P. Patel

Mayo Clinic Alix School of Medicine, Mayo Clinic, Scottsdale, Arizona, USA; Department of Neurologic Surgery, Mayo Clinic, Phoenix, Arizona, USA

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Journal of Neurosurgery
Verified
Journal Article
Closed access
PDF file
JHJack M. Haglin
Jack M. Haglin
KRKent R. Richter
Kent R. Richter
NPNaresh P. Patel
Naresh P. Patel
OBJECTIVE: There is currently a paucity of literature evaluating procedural reimbursements and financial trends in neurosurgery. A comprehensive understanding of the economic trends and financial health of neurosurgery is important to ensure the sustained success and growth of the specialty moving forward. The purpose of this study was to evaluate monetary trends of the 10 most common spinal and cranial neurosurgical procedures in Medicare reimbursement rates from 2000 to 2018.METHODS: The Physician Fee Schedule Look-Up Tool from the Centers for Medicare & Medicaid Services was queried for each of the top 10 most utilized Current Procedural Terminology codes in both spinal and cranial neurosurgery, and comprehensive reimbursement data were extracted. The raw percent change in Medicare reimbursement rate from 2000 to 2018 was calculated for each procedure and averaged. This was then compared to the percent change in consumer price index over the same time. Using data adjusted for inflation, trend analysis was performed for all included procedures. Adjusted R-squared and both the average annual and the total percent change in reimbursement were calculated based on these adjusted trends for all included procedures. Likewise, the compound annual growth rate was calculated for all procedures.RESULTS: When all reimbursement data were adjusted for inflation, the average reimbursement for all procedures decreased by an average of 25.80% from 2000 to 2018. From 2000 to 2018, the adjusted reimbursement rate for all included procedures decreased by an average of 1.59% each year and experienced an average compound annual growth rate of −1.66%, indicating a steady annual decline in reimbursement when adjusted for inflation.CONCLUSIONS: This is the first study to evaluate comprehensive trends in Medicare reimbursement in neurosurgery. When adjusted for inflation, Medicare reimbursement for all included procedures has steadily decreased from 2000 to 2018, with similar rates of decline observed between cranial and spinal neurosurgery procedures. Increased awareness and consideration of these trends will be important moving forward for policy makers, hospitals, and neurosurgeons as continued progress is made to advance agreeable reimbursement models that allow for the sustained growth of neurosurgery in the United States.

1 January 2008 in Surgical Neurology
Verified
Journal Article
Closed access
NPNaresh P. Patel
Naresh P. Patel
WWW. Putnam Wolcott
W. Putnam Wolcott
JJJ. Patrick Johnson
J. Patrick Johnson
HCHelen Cambron
Helen Cambron
MLMarcial Lewin
Marcial Lewin
UBUlrich Batzdorf
Ulrich Batzdorf

1 August 2009 in Journal of Spinal Disorders & Techniques
Verified
Journal Article
Closed access
ENEric W. Nottmeier
Eric W. Nottmeier
HDHugh Gordon Deen
Hugh Gordon Deen
NPNaresh Patel
Naresh Patel
BBBarry Birch
Barry Birch
The authors report on their experience with cervical sagittal deformity correction using 360-degree reconstruction. A paucity of literature exists concerning 360-degree approaches for the correction of cervical kyphotic sagittal deformity in which the amount of deformity correction achieved, as well as the maintenance of deformity correction, is detailed. The charts of all patients undergoing 360-degree cervical reconstruction for kyphotic sagittal plane deformity between 2000 and 2006 at Mayo Clinic Jacksonville and Mayo Clinic Scottsdale were retrospectively reviewed. Only patients with a minimum of 1-year follow-up were included in this study; 41 patients fit this criterion. The clinical data were further analyzed in this cohort to determine preoperative and postoperative sagittal angle, loss of correction, fusion rate, complications, and clinical status at last follow-up. Average follow-up was 19 months (range: 12 to 48 mo). The mean preoperative sagittal angle was 18 degrees of kyphosis (range: 3 to 58 degrees). The mean correction of sagittal angle was 22 degrees (range: 4 to 56 degrees), resulting in a postoperative mean sagittal angle of 4-degree lordosis. There was no loss of correction across the instrumented segments in any patient. Neurologic complications included 1 case of quadriparesis and 1 case of transient C8 radiculopathy. The correction of cervical kyphotic sagittal plane deformity can be accomplished safely and effectively using a 360-degree approach. The incidence of major complications in this study was low. All patients could be corrected to a neutral or lordotic alignment. No loss of deformity correction was seen in any patient, and a 97.5% fusion rate was obtained.

19 August 2022 in Surgical Neurology International
Verified
Journal Article
Open access
RSRohin Singh
Rohin Singh
KWKendra Wang
Kendra Wang
MQMuhammad Bilal Qureshi
Muhammad Bilal Qureshi
IRIndia C. Rangel
India C. Rangel
NBNolan J Brown
Nolan J Brown
MBMohamad Bydon
Mohamad Bydon
Background: The first instance of a robotic-assisted surgery occurred in neurosurgery; however, it is now more common in other fields such as urology and gynecology. This study aims to characterize the prevalence of robotic surgery among current neurosurgery programs as well as identify trends in clinical trials pertaining to robotic neurosurgery. Methods: Each institution’s website was analyzed for the mention of a robotic neurosurgery program and procedures. The future potential of robotics in neurosurgery was assessed by searching for current clinical trials pertaining to neurosurgical robotic surgery. Results: Of the top 100 programs, 30 offer robotic cranial and 40 offer robotic spinal surgery. No significant differences were observed with robotic surgical offerings between geographic regions in the US. Larger programs (faculty size 16 or over) had 20 of the 30 robotic cranial programs (66.6%), whereas 21 of the 40 robotic spinal programs (52.5%) were at larger programs. An initial search of clinical trials revealed 223 studies, of which only 13 pertained to robotic neurosurgery. Spinal fixation was the most common intervention (six studies), followed by Deep Brain Stimulation (DBS, two studies), Cochlear implants (two studies), laser ablation (LITT, one study), and endovascular embolization (one study). Most studies had industry sponsors (9/13 studies), while only five studies had hospital sponsors. Conclusion: Robotic neurosurgery is still in its infancy with less than half of the top programs offering robotic procedures. Future directions for robotics in neurosurgery appear to be focused on increased automation of stereotactic procedures such as DBS and LITT and robot-assisted spinal surgery.

18 June 2022 in World Neurosurgery
Verified
Journal Article
Closed access
RSRohin Singh
Rohin Singh
MMM. Lane Moore
M. Lane Moore
HHHana Hallak
Hana Hallak
NSNathan A. Shlobin
Nathan A. Shlobin
NBNolan J Brown
Nolan J Brown
NPNaresh P. Patel
Naresh P. Patel

24 May 2005 in Neurology
Verified
Journal Article
Closed access
PDF file
JGJonathan P. Gladstone
Jonathan P. Gladstone
KNKent Nelson
Kent Nelson
NPNaresh Patel
Naresh Patel
DDDavid W. Dodick
David W. Dodick