Guangyu Zhu

Guangyu Zhu

Auto-generated profile, based on publicly available information

Guangyu Zhu

Department of Computer Science and Engineering, Chung-Ang University, Seoul 06974, Korea

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2020 in IEEE Access
Verified
Journal Article
Open access
GZGuangyu Zhu
Guangyu Zhu
JHJaehyun Han
Jaehyun Han
YSYongseok Son
Yongseok Son
NAND Flash-based solid-state drives (SSDs) have been widely used as secondary storage devices due to their faster access speed, lower power consumption, and higher reliability compared with hard disk drives. However, application I/O performance can be significantly affected by garbage collection (GC) inside SSDs. For example, a GC operation usually moves valid pages from a victim block into a clean block in a serialized manner. Thus, it increases the GC time and affects the application I/O performance. To address this issue, this article presents a preliminary study on a parallel GC scheme for flash-based SSDs. In our scheme, we parallelize valid page migrations during a GC operation to reduce the total GC time. To do this, we first propose a new flash chip architecture that enables valid page migrations in parallel. Second, we collect information such as new addresses for the migration of valid pages by considering the restriction of SSD operations. Finally, we employ multiple worker threads to migrate the valid pages using the collected information in a parallel manner. We implement and evaluate our scheme using Disksim with Microsoft SSD extension. The experimental result shows that the proposed scheme reduces the overall GC time by 70% and 57% on average compared with the existing scheme and a state-of-the-art GC scheme IPPBE, respectively.

13 January 2021
Verified
Conference Paper
Closed access
JHJaehyun Han
Jaehyun Han
GZGuangyu Zhu
Guangyu Zhu
ELEunseo Lee
Eunseo Lee
SLSangmook Lee
Sangmook Lee
YSYongseok Son
Yongseok Son
Cloud Computing as a service-on-demand architecture has grown in importance over the previous few years. The storage subsystem in cloud computing has undergone enormous innovation in order to provide high-quality cloud services. Emerging non-volatile memory express (NVMe) technology has a considerable attraction in cloud computing by delivering high I/O performance in terms of latency and bandwidth. Especially, multiple NVMe SSDs can provide higher performance, fault tolerance, and storage capacity in the cloud computing environment. In this paper, we perform an empirical evaluation study of performance on recent NVMe SSDs (i.e., Intel Optane SSDs) with different RAID environments. We analyze the performance of the multiple NVMe SSDs with RAID in terms of different performance metrics via micro and macro benchmarks. We anticipate that the experimental results and performance analysis will provide the implications on various storage systems.

17 August 2021 in Electronics
Verified
Journal Article
Open access
PDF file
GZGuangyu Zhu
Guangyu Zhu
JHJaehyun Han
Jaehyun Han
SLSangjin Benjamin Lee
Sangjin Benjamin Lee
YSYongseok Son
Yongseok Son
The emergence of non-volatile memories (NVM) brings new opportunities and challenges to data management system design. As an important part of the data management systems, several new file systems are developed to take advantage of the characteristics of NVM. However, these NVM-aware file systems are usually designed and evaluated based on simulations or emulations. In order to explore the performance and characteristics of these file systems on real hardware, in this article, we provide an empirical evaluation of NVM-aware file systems on the first commercially available byte-addressable NVM (i.e., the Intel Optane DC Persistent Memory Module (DCPMM)). First, to compare the performance difference between traditional file systems and NVM-aware file systems, we evaluate the performance of Ext4, XFS, F2FS, Ext4-DAX, XFS-DAX, and NOVA file systems on DCPMMs. To compare DCPMMs with other secondary storage devices, we also conduct the same evaluations on Optane SSDs and NAND-flash SSDs. Second, we observe how remote NUMA node access and device mapper striping affect the performance of DCPMMs. Finally, we evaluate the performance of the database (i.e., MySQL) on DCPMMs with Ext4 and Ext4-DAX file systems. We summarize several observations from the evaluation results and performance analysis. We anticipate that these observations will provide implications for various memory and storage systems.

31 May 2021 in Electronics
Verified
Journal Article
Open access
PDF file
JHJaehyun Han
Jaehyun Han
GZGuangyu Zhu
Guangyu Zhu
SLSangmook Lee
Sangmook Lee
YSYongseok Son
Yongseok Son
Cloud computing as a service-on-demand architecture has grown in importance over the last few years. The storage subsystem in cloud computing has undergone enormous innovation to provide high-quality cloud services. Emerging Non-Volatile Memory Express (NVMe) technology has attracted considerable attention in cloud computing by delivering high I/O performance in latency and bandwidth. Specifically, multiple NVMe solid-state drives (SSDs) can provide higher performance, fault tolerance, and storage capacity in the cloud computing environment. In this paper, we performed an empirical evaluation study of performance on recent NVMe SSDs (i.e., Intel Optane SSDs) with different redundant array of independent disks (RAID) environments. We analyzed multiple NVMe SSDs with RAID in terms of different performance metrics via synthesis and database benchmarks. We anticipate that our experimental results and performance analysis will have implications for various storage systems. Experimental results showed that the software stack overhead reduced the performance by up to 75%, 52%, 76%, 91%, and 92% in RAID 0, 1, 10, 5, and 6, respectively, compared with theoretical and expected performance.