4 November 2019 in Applied Biological Chemistry
Heavy metals including Lead (Pb), Cadmium (Cd), Arsenic (As) and Aluminium (Al) were analysed in oilseeds, noodles, tea leaves and their processed or cooked products to study the effects of food processing methods on migration of heavy metals. The heavy metals were determined with ICP-MS and ICP-OES following microwave-assisted acid digestion. Heavy metals in oilseeds, noodles and teas were reduced by extracting oils, boiling noodles, and infusing teas. And the transfer of heavy metals into boiling water and infusion tea was increased as the boiling and infusion time is increased. Heavy metals in foods are water soluble and heavy metals in foods would be decreased when foods are processed or cooked with water. Furthermore, it is needed to determine the migration rates in other cooked foods and assess the risk of heavy metals with concentrations calculated by the migration rates.
11 June 2020 in Environmental Science and Pollution Research
2 May 2013 in Macromolecular Research
1 July 2015 in International Journal of Pharmaceutics
1 January 2020 in Journal of AOAC INTERNATIONAL
Background: There are two methods for quantifying methylmercury (MeHg) in fish using GC–electron capture detection (ECD): AOAC INTERNATIONAL Official Method 988.11 and the Korean Food Code (KFC) method. Both of these methods consume a large amount of chemicals and require long pretreatment times because of several complicated MeHg extraction steps. Objective: In this study, a new method for the simple and rapid determination of MeHg in fish has been developed. The method is based on the investigation of oxygen combustion–gold amalgamation using a direct mercury analyzer (DMA) after the complete removal of MeHg by organic extraction and back-extraction to an aqueous medium. Methods: The DMA is suitable for the analysis of both solid and liquid materials and has a good detection limit. The developed method was validated by comparing the MeHg recoveries (%) of both certified reference materials and the market-purchased fish samples with the MeHg concentration obtained using the KFC method. Results: The following parameters pertaining to the developed method were established: detection limit, 1.02 μg/kg; LOQ, 3.09 μg/kg; linearity (r), 0.9998; range, 0.1–300 μg/kg; and recovery, 95–97%. Conclusions: Our method is a promising alternative by virtue of its much simpler and faster sample pretreatment procedure, with a MeHg recovery as high as that of the KFC method. Highlights: The developed method enables the simultaneous analysis of total Hg and MeHg with only DMA equipment.
1 February 2011 in Journal of Nanoscience and Nanotechnology
In this study, dexamethasone was conjugated to PAMAM dendrimer (generation 0) and its gene transfection efficiency was investigated. To make a liposomal solution for gene delivery, DOPE was used as a fusogenic helper lipid. In gel retardation assay, PAMAM-dexamethasone conjugate (PAM-Dex)/DOPE liposome/DNA complex was completely retarded at 8:1 N/P (nitrogen/phosphate) ratio. The physicochemical characteristics are studied by measuring the average size distribution and ζ-potential values of the complexes. In vitro transfection assay showed that the PAM-Dex/DOPE liposome/DNA complex displayed higher gene delivery efficiency compared to PAMAM/DNA complex. In addition, PAM-Dex/DOPE liposome showed the lowest toxicity compared to PAMAM, PEI 25 kD and Lipofectamine. These results indicate that PAM-Dex/DOPE liposome has a potential to be used as an efficient gene carrier for gene therapy.