In this paper, we describe a novel fabrication method of a microfluidic integrated surface plasmon resonance (SPR) gold chip based on a (3-mercaptopropyl) trimethoxy silane (MPTMS) self-assembled monolayer. This monolayer was formed at the surface of a microfluidic chip made of polydimethylsiloxane (PDMS). Its presence was confirmed by contact angle and Fourier transform infrared spectroscopy measurements on the modified PDMS surface. A basic, but nevertheless appropriate, 4-channel microfluidic system was made on PDMS and reported on a gold SPR sensor. Sealing tests were carried-out by injecting continuous flows of solutions under gradient pressure up to 1.8 bar. Bonding strength of chemical and corona binding were measured and compared. The test of the integrated microfluidic SPR sensor on an SPR bench validated its functionality and proved as well that no leakage is observed between the different microfluidic channels.
We report the optical characterization of an InP structure constituted by waveguides coupled to microcavity disk resonators. The lateral waveguide confinement is obtained by deep reactive ion etching through the guiding layer. We demonstrate the possibility of tuning optically the resonance wavelength into the illuminating disk resonator. We obtained a blueshift of by laser irradiation at corresponding to a photoinduced change in the effective refractive index of . The InP structure behaves as a tunable optical demultiplexer.
Surface plasmon resonance (SPR) sensing is a well-established high-sensitivity, label-free and real-time detection technique for biomolecular interaction study. Its primary working principle consists of the measurement of the optical refractive index of the medium that is in close vicinity of the sensor surface. Bio-functionalization techniques allow biomolecular events to be located in such a way. Since optical refractive indices of any medium varies with the temperature, the place where the measurement takes place shall be within a temperature-controlled environment in order to ensure any temperature fluctuation is interpreted as a biomolecular event. Since the SPR measurement probes the sensed medium within the penetration depth of the plasmonic wave, which is less or in the order of 1 µm, we propose to use the metallic film constituting the detection surface as a localized heater aiming at controlling finely and quickly the temperature of the sensed medium. The Joule heating principle is then used and the modeling of the heater is reported as well as its validation by thermal IR imaging. Using water as a demonstration medium, SPR measurement results at different temperatures are successfully compared to the theoretical optical refractive index of water versus temperature.
1 November 1992 in IEEE Photonics Technology Letters
Microwave impedance matching networks have been, for the first time, monolithically integrated with GaInAs p-i-n photodiodes and GaInAsP buried ridge stripe structure lasers ( lambda =1.3 mu m), both on a semi-insulating InP substrate. The microwave power transfer optical links were compared using matched and unmatched devices. Compared to an unmatched link, an improvement of 11.4 dB at 5.6 GHz (600 MHz bandwidth) is obtained for the totally matched one; this result corresponds quite well to the theoretical prediction (12 dB at 6 GHz).