During the decommissioning of the Fukushima Daiichi nuclear power plant, it is important to consider the retrieval of resolidified debris both in air and underwater configurations. For the subsequent retrieval of debris from the reactor building, the resolidified debris must be cut into smaller pieces using various cutting methods. During the cutting process, aerosol particles are expected to be generated at the submicron scale. It has been noted that such aerosols sizing within the Greenfield gap (0.1–1 μm) are difficult to remove effectively using traditional spraying methods. Therefore, to improve the aerosol removal efficiency of the spray system, a new aerosol agglomeration method was recently proposed, which involves injecting water mist to enlarge the sizes of the aerosol particles before removing them using water sprays. In this study, a series of experiments were performed to clarify the proper spray configurations for effective aerosol scavenging and to improve the performance of the water mist. The experimental results showed that the spray flow rate and droplet characteristics are important factors for the aerosol-scavenging efficiency and performance of the water mist. The results obtained from this study will be helpful for the optimization of the spray system design for effective aerosol scavenging during the decommissioning of the Fukushima Daiichi plant.
The recent Nuclear Regulation Authority evaluation report suggests that at the Fukushima Daiichi Nuclear Power Station, the concrete shield plugs above the primary containment vessel (PCV) have exceptionally high radiation levels in Units 2 and 3, which may increase the risk of radiation exposure during decommissioning operations. During the cleaning and disassembly of such radiation hot spots, it is expected that a large amount of submicron-sized radioactive aerosol particles will be generated, which may influence the decommissioning operation. In the present study, laser cleaning experiments were conducted at the University of Tokyo Aerosol Removal Test Facility to simulate aerosol scavenging during the laser cleaning process. The facility can reproduce multiple phenomena expected in actual plant decommissioning, such as laser decontamination and simultaneous mist and spraying operations. Through the work, we have developed effective aerosol dispersion control methods and strategies based on the joint use of water mist and water spray to reduce radiation risk in either laser cutting or other means of decontamination methods. Preliminary laser cleaning experiments on various coated samples were conducted to assess the aerosol removal efficiency using water droplets and mist. It was verified that the proposed method effectively cleans the radiation hot spots during the decommissioning process.