Stefan Rosén

Stefan Rosén

Auto-generated profile, based on publicly available information

Stefan Rosén

Department of Physics, AlbaNova University Center, Stockholm University, SE-106 91 Stockholm, Sweden

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 1998 in The Astrophysical Journal
Verified
Journal Article
Open access
PDF file
ALA. Larson
A. Larson
APA. Le Padellec
A. Le Padellec
JSJ. Semaniak
J. Semaniak
CSC. Stromholm
C. Stromholm
MLM. Larsson
M. Larsson
SDS. Datz
S. Datz
The absolute cross section and branching ratios for dissociative recombination of CH2+ with electrons have been measured by means of the heavy-ion storage ring CRYRING. Contrary to what has been previously believed, recombination of CH2+ is dominated by the three-body channel C + H + H (63%), whereas breakup into the CH + H and C + H2 channels occurs with branching ratios of 25% and 12%, respectively. The thermal rate coefficient for dissociative recombination at 300 K is 6.4 × 10-7 cm3 s-1, which is higher by a factor of 2.5 than the value used in modeling dark molecular clouds. The low CH production and the high production of energetic carbon atoms could be favorable factors for the turbulence model to explain the large abundance of interstellar CH+. The cross section for dissociative excitation was also measured and found to be in good agreement with results from a crossed electron-ion beam experiment. © 1998. The American Astronomical Society. All rights reserved

1 November 2007 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SRStefan Rosén
Stefan Rosén
HSHenning T. Schmidt
Henning T. Schmidt
PRPeter Reinhed
Peter Reinhed
DFDaniel Fischer
Daniel Fischer
RTRichard D. Thomas
Richard D. Thomas
MBMikael Blom
Mikael Blom
An assembly consisting of a stack of three microchannel plates (MCPs) and a phosphor screen anode has been operated over the temperature range from 300to12K . We report on measurements at 6.4kHz (using an alpha source) and with dark counts only (15Hz) . Without any particle source, the MCP bias current decreased by a factor of 2.1×103 when the temperature was lowered from 300to12K . Using the alpha source, and a photomultiplier tube (PMT) to monitor the phosphor screen anode, we first observed an increase in the decay time of the phosphor from 12to45μs when the temperature was decreased from 300to100K while the decay time then decreased and reached a value of 5μs at 12K . The pulse height distribution from the PMT was measured between 300 and 12K and shows a spectrum typical for a MCP phosphor setup at 300K and 12K but is strongly degraded for intermediate temperatures. We conclude that the present MCP-phosphor detector assembly is well suited for position-sensitive particle counting operation at temperatures down to at least 12K even for count rates beyond 6kHz . This result is crucial and an important part of ongoing developments of new instrumentation for investigations of, e.g., interactions involving complex molecular ions with internal quantum state control.